Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Polym Sci B Polym Phys ; 56(3): 255-264, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31806922

RESUMO

The influence of monomer functionality on the mechanical properties of epoxies is studied using Molecular Dynamics (MD) with the Reax Force Field (ReaxFF). From deformation simulations, the Young's modulus, yield point, and Poisson's ratio are calculated and analyzed. The results demonstrate an increase in stiffness and yield strength with increasing resin functionality. Comparison between the network structures of distinct epoxies is further advanced by the Monomeric Degree Index (MDI). Experimental validation demonstrates the MD results correctly predict the relationship in Young's moduli. Therefore, ReaxFF is confirmed to be a useful tool for studying the mechanical behavior of epoxies.

2.
Poromechanics V (2013) ; 2013: 2174-2183, 2013 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-25541627

RESUMO

Measurement of individual muscle tension in a clinical setting has yet to be achieved. Previous investigators have suggested that the tension in skeletal muscle, comprised of approximately 70% fluid, could be determined using interstitial muscle fluid pressure (IMP). A computational model is needed to aid in understanding IMP distribution in muscles of varying geometry and contractile states without exhaustive testing. The first aim of this study was to determine a set of transversely isotropic material properties (i.e., permeability, relaxed modulus, and drained Poisson's ratio) for excised skeletal muscle using inverse finite element analysis with a poroelastic constitutive formulation on tension data from either longitudinal or transverse uniaxial load-relaxation tests of skeletal muscle tissue. The second aim was to compare pore pressure estimated from a model to experimental pressure measurements to assess its ability to accurately predict IMP. Results of this study indicated that skeletal muscle was transversely isotropic under load-relaxation as demonstrated by significant differences in the drained Poisson's ratio. It was also noted that the drained Poisson's ratios under both longitudinal and transverse loading were negative in these tests of excised muscle tissue. Pore pressure calculated with this model provided a good prediction of the development of IMP. These results point to the benefit of using a poroelastic model of skeletal muscle to predict IMP.

3.
J Mech Behav Biomed Mater ; 2(4): 339-47, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19627840

RESUMO

The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal body, allowing the menisci to assist in load transmission from the femur to the tibia. Clinically, tears and ruptures of the meniscal attachments and insertion to bone are rare. While it has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau, little is known about the material properties of meniscal attachments and the transition in material properties from the meniscus to subchondral bone. The objective of this study was to use nanoindentation to investigate the transition from meniscal attachment into underlying subchondral bone through uncalcified and calcified fibrocartilage. Nanoindentation tests were performed on both the anterior and posterior meniscal insertions to measure the instantaneous elastic modulus and elastic modulus at infinite time. The elastic moduli were found to increase in a bi-linear fashion from the external ligamentous attachment to the subchondral bone. The elastic moduli for the anterior attachments were consistently larger than those for the matching posterior attachments at similar indentation locations. These results show that there is a gradient of stiffness from the superficial zones of the insertion close to the ligamentous attachment into the deeper zones of the bone. This information will be useful in the continued development of successful meniscal replacements and understanding of fixation of the replacements to the tibial plateau.


Assuntos
Meniscos Tibiais , Nanotecnologia , Tíbia , Fenômenos Biomecânicos , Calcificação Fisiológica , Módulo de Elasticidade , Testes de Dureza , Humanos , Masculino , Meniscos Tibiais/fisiologia , Pessoa de Meia-Idade , Fatores de Tempo
4.
J Biomech Eng ; 130(6): 061017, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19045546

RESUMO

While much work has previously been done in the modeling of skeletal muscle, no model has, to date, been developed that describes the mechanical behavior with an explicit strain-energy function associated with the active response of skeletal muscle tissue. A model is presented herein that has been developed to accommodate this design consideration using a robust dynamical approach. The model shows excellent agreement with a previously published model of both the active and passive length-tension properties of skeletal muscle.


Assuntos
Transferência de Energia/fisiologia , Modelos Biológicos , Músculo Esquelético/fisiologia , Animais , Anisotropia , Simulação por Computador , Módulo de Elasticidade/fisiologia , Humanos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...