Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Malar J ; 12: 113, 2013 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-23537145

RESUMO

BACKGROUND: Malaria diagnosis is largely dependent on the demonstration of parasites in stained blood films by conventional microscopy. Accurate identification of the infecting Plasmodium species relies on detailed examination of parasite morphological characteristics, such as size, shape, pigment granules, besides the size and shape of the parasitized red blood cells and presence of cell inclusions. This work explores misclassifications of four Plasmodium species by conventional microscopy relative to the proficiency of microscopists and morphological characteristics of the parasites on Giemsa-stained blood films. CASE DESCRIPTION: Ten-day malaria microscopy remedial courses on parasite detection, species identification and parasite counting were conducted for public health and research laboratory personnel. Proficiency in species identification was assessed at the start (pre) and the end (post) of each course using known blood films of Plasmodium falciparum, Plasmodium malariae, Plasmodium ovale and Plasmodium vivax infections with densities ranging from 1,000 to 30,000 parasites/µL. Outcomes were categorized as false negative, positive without speciation, P. falciparum, P. malariae, P. ovale, P. vivax and mixed infections. DISCUSSION AND EVALUATION: Reported findings are based on 1,878 P. falciparum, 483 P. malariae, 581 P. ovale and 438 P. vivax cumulative results collated from 2008 to 2010 remedial courses. Pre-training false negative and positive misclassifications without speciation were significantly lower on P. falciparum infections compared to non-falciparum infections (p < 0.0001). Post-training misclassifications decreased significantly compared to pre- training misclassifications which in turn led to significant improvements in the identification of the four species. However, P. falciparum infections were highly misclassified as mixed infections, P. ovale misclassified as P. vivax and P. vivax similarly misclassified as P. ovale (p < 0.05). CONCLUSION: These findings suggest that the misclassification of malaria species could be a common occurrence especially where non-falciparum infections are involved due to lack of requisite skills in microscopic diagnosis and variations in morphological characteristics within and between Plasmodium species. Remedial training might improve reliability of conventional light microscopy with respect to differentiation of Plasmodium infections.


Assuntos
Erros de Diagnóstico , Pessoal de Laboratório , Malária/diagnóstico , Microscopia/métodos , Parasitologia/métodos , Plasmodium/classificação , Plasmodium/citologia , Educação Médica Continuada , Humanos , Malária/parasitologia , Competência Profissional , Coloração e Rotulagem/métodos
2.
Malar J ; 7: 22, 2008 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-18226243

RESUMO

BACKGROUND: Malaria microscopy remains the reference standard for malaria diagnosis in clinical trials (drug and vaccine), new diagnostic evaluation, as well as in clinical care in much of the world today. It is known that microscopy is an imperfect gold standard, and that very low false positive rates can dramatically lower protective efficacy estimates in malaria prevention trials. Although new methods are now available, including malaria rapid diagnostic tests and PCR, neither is as yet validated in the clinical trial setting and both have limitations. Surprisingly, the sensitivity of thin smears is not well established and thin smears are not commonly used in the developing world. METHODS: Malaria thick and thin films were collected in the lowlands of Western Kenya. All had density determined by four readings with two methods, as well as species identified. Thirty-six with low density parasitaemia had the thin smear read by five independent microscopists, two were expert and three were qualified. Microscopists read the entire thin film. For the first 10 parasites seen, they reported the species, appearance, time, field number, and red blood cells in the field. Total parasites, total fields, and total time to examine the smear were also recorded. RESULTS: Median parasitaemia was 201 parasites/mul, mean 1,090 +/- 2,195, range 6-11,124 parasites/mul for the 36 smears evaluated. The data revealed a density dependent increase in sensitivity, with 100% sensitivity achieved at >200 parasites/mul for experts and >500 parasites/mul for qualified readers. Thin film readings confirmed parasitaemia 74% of the time by experts, and 65% of the time for qualified microscopists. The 95th percentile for time to detect parasitaemia was 15 minutes for experts, 17 minutes for qualified microscopists. This decreased to 4-10 minutes for experts at densities of > 200 parasites/mul. Additionally, substantial discordance for species identification was observed. CONCLUSION: The thin film is sensitive enough to be a useful tool to confirm malaria diagnosis in study subjects in some settings. Specificity of the thin film and its utility for confirming thick film or other diagnostic test results should be assessed further.


Assuntos
Testes Diagnósticos de Rotina/normas , Malária/diagnóstico , Parasitemia/diagnóstico , Plasmodium/isolamento & purificação , Animais , Eritrócitos/parasitologia , Humanos , Quênia , Malária/parasitologia , Microscopia , Projetos Piloto , Plasmodium/classificação , Sensibilidade e Especificidade
3.
Malar J ; 6: 79, 2007 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-17565676

RESUMO

BACKGROUND: Malaria microscopy, while the gold standard for malaria diagnosis, has limitations. Efficacy estimates in drug and vaccine malaria trials are very sensitive to small errors in microscopy endpoints. This fact led to the establishment of a Malaria Diagnostics Centre of Excellence in Kisumu, Kenya. The primary objective was to ensure valid clinical trial and diagnostic test evaluations. Key secondary objectives were technology transfer to host countries, establishment of partnerships, and training of clinical microscopists. CASE DESCRIPTION: A twelve-day "long" and a four-day "short" training course consisting of supervised laboratory practicals, lectures, group discussions, demonstrations, and take home assignments were developed. Well characterized slides were developed and training materials iteratively improved. Objective pre- and post-course evaluations consisted of 30 slides (19 negative, 11 positive) with a density range of 50-660 parasites/mul, a written examination (65 questions), a photographic image examination (30 images of artifacts and species specific characteristics), and a parasite counting examination. DISCUSSION AND EVALUATION: To date, 209 microscopists have participated from 11 countries. Seventy-seven experienced microscopists participated in the "long" courses, including 47 research microscopists. Sensitivity improved by a mean of 14% (CI 9-19%) from 77% baseline (CI 73-81 %), while specificity improved by a mean of 17% (CI 11-23%) from 76% (CI 70-82%) baseline. Twenty-three microscopists who had been selected for a four-day refresher course showed continued improvement with a mean final sensitivity of 95% (CI 91-98%) and specificity of 97% (CI 95-100%). Only 9% of those taking the pre-test in the "long" course achieved a 90% sensitivity and 95% specificity, which increased to 61% of those completing the "short" course. All measures of performance improved substantially across each of the five organization types and in each course offered. CONCLUSION: The data clearly illustrated that false positive and negative malaria smears are a serious problem, even with research microscopists. Training dramatically improved performance. Quality microscopy can be provided by the Centre of Excellence concept. This concept can be extended to other diagnostics of public health importance, and comprehensive disease control strategies.


Assuntos
Currículo , Educação , Malária/diagnóstico , Pessoal de Laboratório Médico/educação , Microscopia/normas , Plasmodium/citologia , Animais , Reações Falso-Negativas , Reações Falso-Positivas , Humanos , Quênia , Controle de Qualidade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...