Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Med Sci Monit ; 21: 2666-71, 2015 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-26363865

RESUMO

BACKGROUND: The aim of this study was to simulate implant placement in the maxillary sinus septum, as a potential alternative site to avoid sinus grafting. MATERIAL AND METHODS: One hundred partially or completely edentulous patients, with their maxillary sinus septum present in the edentulous region, were selected from the database of the Department of Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Bruxelles, Belgium. Three-dimensional (3D) reconstructions were created using 3D planning software. 3D reconstructions were performed for each maxillary sinus. Using the software implant library, the implants that presented the best fit with the maxillary sinus septum and that followed the established inclusion criteria were selected. RESULTS: All of the implants were inserted in premolar and molar regions. Most implants were inserted in the position of the second molar (21 of 55) or in the position of the first molar (17 of 55). In all sites the most frequently used implant was 4 mm in diameter and 7 mm in height. The mean coronal angle for the implant was 80.19±17.13 degrees and the mean sagittal angle was 94.83±9.94 degrees. The septal height represents 38.13% of the total available bone height (ABH). The mean percentage of the septum used to insert the implants was 47.33±2.47%. The septum increased the available bone height by a mean value of 2.18±1.47 mm. In 45 cases, the septa did not permit implant placement. CONCLUSIONS: In completely edentulous patients, inserting implants in sinus septa does not exclude the need for sinus grafting, but in partially edentulous patients, this minimally invasive technique is an alternative to subantral augmentation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional , Seio Maxilar/diagnóstico por imagem , Dente Pré-Molar/diagnóstico por imagem , Implantes Dentários , Humanos , Dente Molar/diagnóstico por imagem , Boca Edêntula/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software
2.
Ann Fr Anesth Reanim ; 28(4): 352-7, 2009 Apr.
Artigo em Francês | MEDLINE | ID: mdl-19339151

RESUMO

The usefulness of therapeutic hypothermia is highly debated after traumatic brain injury. A neuroprotective effect has been demonstrated only in experimental studies: decrease in cerebral metabolism, restoration of ATP level, better control of cerebral edema and cellular effects. Despite negative multicenter clinical studies, therapeutic hypothermia is still used to a better control of intracranial pressure. However, important issues need to be clarified, particularly the level and duration of hypothermia, the depth and modalities of sedation. A clear understanding of blood gases variations induced by hypothermia is needed to understand the cerebral perfusion and oxygenation changes. It is essential to recognize and to use hypothermia-induced physiological hypocapnia and alkalosis under strict control of cerebral oxygen balance (jugular venous saturation or tissue PO(2)) and also to take into account the increased affinity of hemoglobin for oxygen. Management of post-traumatic intracranial hypertension using hypothermia, directed by intracranial pressure level, and consequently for long duration, is potentially beneficial but needs further clarification.


Assuntos
Gasometria , Dano Encefálico Crônico/prevenção & controle , Dióxido de Carbono/sangue , Traumatismos Craniocerebrais/terapia , Hipotermia Induzida , Oxigênio/sangue , Alcalose Respiratória/prevenção & controle , Animais , Encéfalo/metabolismo , Traumatismos Craniocerebrais/sangue , Sedação Profunda , Metabolismo Energético , Aminoácidos Excitatórios/metabolismo , Parada Cardíaca/complicações , Humanos , Hipotermia Induzida/métodos , Hipotermia Induzida/estatística & dados numéricos , Pressão Parcial , Ratos , Fatores de Tempo , Resultado do Tratamento
3.
Ann Fr Anesth Reanim ; 27(11): 945-8, 2008 Nov.
Artigo em Francês | MEDLINE | ID: mdl-18954957

RESUMO

We report a case of a falsely elevated-bispectral index (BIS) during a general anaesthesia combining remifentanil TCI, desflurane and nitrous oxide for an isolated-limb chemotherapy. During surgery, BIS increased and stabilized around 70, with neither residual neuromuscular blockade nor clinical sign of awareness. These high BIS values were attributed to high-electromyographic activity and electric artefacts, such as extracorporeal-circulation machine and tourniquet. At the end of the surgery, the BIS returned to expected values around 50. The patient did not complain of intraoperative recall. This case reminds us that the BIS has some limits as being sensitive to EMG or environment artefacts that should be eliminated before deepening anesthesia. To do so, a decision algorithm is proposed that may be used for all situations of surprising high BIS, taking into account the level of neuromuscular blockade, clinical response to orders and the presence of devices likely to induce electrical or mechanical artefacts.


Assuntos
Anestesia , Eletroencefalografia , Monitorização Intraoperatória , Idoso , Reações Falso-Positivas , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA