Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Radiol (Mosk) ; 36(5): 21-3, 1991.
Artigo em Russo | MEDLINE | ID: mdl-1827860

RESUMO

Karyometric analysis of blood lymphocytes of persons, exposed to low levels of radiation (up to 25 rem) during elimination of the consequences of the Chernobyl accident, has shown changes of lymphocyte densitometric-geometric parameters, characteristic for radiation exposure, observed in 188 of 294 examinees. The meaning of these statistically significant changes is the following: percentage of the level of large lymphocytes is on the decrease whereas that of average and small ones is on the decrease. There is also a parallel rise of values of the area and perimeter of a lymphocyte nuclear section. The above shifts were observed against a background of normal indices of the absolute number and a relative content of blood lymphocytes. Karyometric analysis of lymphocytes indicated signs of radiation exposure 1-33 mos. after irradiation at small doses. Cytogenetic verification of diagnosis has shown sensitivity of the karyometric method of biological demonstration [correction of bioindication], which can be recommended as an additional diagnostic test in chronic exposure to low levels of radiation for retrospective assessment.


Assuntos
Linfócitos/efeitos da radiação , Acidentes , Armênia , Relação Dose-Resposta à Radiação , Humanos , Cariometria/métodos , Contagem de Leucócitos/efeitos da radiação , Linfócitos/ultraestrutura , Reatores Nucleares , Doenças Profissionais/sangue , Doenças Profissionais/diagnóstico , Exposição Ocupacional/efeitos adversos , Centrais Elétricas , Lesões por Radiação/sangue , Lesões por Radiação/diagnóstico , Fatores de Tempo , Ucrânia
3.
Radiobiologiia ; 26(4): 535-40, 1986.
Artigo em Russo | MEDLINE | ID: mdl-3749479

RESUMO

The possibility of application of mathematical methods of the image recognition theory for the estimation of radiation damage severity (RDS) is grounded. The application of the method for the RDS estimation according to densito-geometrical parameters of the peripheral blood lymphocytes is described. The decisive rules for the estimation of the RDS within the feature space are developed. The obtained statistically valid linear discriminant functions possess a high descriptive and prognostic power.


Assuntos
Linfócitos/efeitos da radiação , Doses de Radiação , Lesões Experimentais por Radiação/diagnóstico , Animais , Contagem de Leucócitos/efeitos da radiação , Linfócitos/patologia , Matemática , Modelos Teóricos , Prognóstico , Ratos , Ratos Endogâmicos
5.
Tsitologiia ; 27(3): 356-9, 1985 Mar.
Artigo em Russo | MEDLINE | ID: mdl-3992666

RESUMO

A method of karyometric analysis of blood cells and the hardware for its realization are described. The method is based on TV object image analysis, and involves measuring videosignal parameters.


Assuntos
Células Sanguíneas/ultraestrutura , Cariometria/instrumentação , Televisão/instrumentação , Animais , Computadores , Apresentação de Dados , Desenho de Equipamento , Microscopia/instrumentação , Ratos
6.
Tsitologiia ; 25(8): 985-7, 1983 Aug.
Artigo em Russo | MEDLINE | ID: mdl-6356537

RESUMO

A use of the TV image for measuring volumes and squares of blood cell nuclei irregular in shape is considered. The linear correspondence has been detected between the volumetric-spatial structure of the object and the shape of the respective video-signal, this correspondence being mathematically proved. The measuring of parametres of video-signal may be informative of the object's shape.


Assuntos
Cariometria/métodos , Televisão/métodos , Animais , Células Sanguíneas/ultraestrutura , Humanos , Matemática , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...