Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bull Environ Contam Toxicol ; 112(5): 74, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733375

RESUMO

Polycyclic aromatic hydrocarbons (PAHs), dust, and wax were measured in pine needles, and PAHs were also measured in surface soil. Pearson correlation analysis was performed between the analytical values. The main compounds responsible for the increase in total PAHs were non-carcinogenic phenanthrene and fluoranthene. Therefore, the % content of carcinogenic PAHs decreased with a slope = -0.037 (r = 0.47, p < 0.01), as the total PAH concentration in pine needles increased. Correlations between individual PAHs in pine needles and surface soil were very high when only low-number ring PAHs (2R- and 3R-PAHs) were statistically analyzed and significant when only high-number ring PAHs were statistically analyzed. Low-number ring PAH mainly moves in the gas phase and diffuses into the wax layer, so it was found to be statistically significant with the wax content of pine needles. High-number ring PAHs showed a high correlation with the amount of dust in pine needles because they mainly attached to dust particles and accumulated on the surface of pine needles. The ratios of fluoranthene/pyrene and methylphenanthrene/phenanthrene for predicting the origin of atmospheric PAHs have also been proven valid for pine needles.


Assuntos
Monitoramento Ambiental , Pinus , Hidrocarbonetos Policíclicos Aromáticos , Hidrocarbonetos Policíclicos Aromáticos/análise , Pinus/química , República da Coreia , Folhas de Planta/química , Fenantrenos/análise , Poluentes do Solo/análise , Poluentes Atmosféricos/análise
2.
Anal Bioanal Chem ; 416(6): 1363-1374, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38285226

RESUMO

Several countries have exempted synthetic nicotine from existing regulatory frameworks, resulting in the widespread substitution of synthetic nicotine (SN) in almost all e-cigarette products available. However, it remains uncertain whether the purported synthetic nicotine is indeed genuine SN. There is a need to develop biological indicators and an analytical method that more clearly distinguishes between the two sources. Impurities in neat tobacco-derived nicotine (TDN) were characterized and identified through non-targeted and targeted analysis. Gas chromatography-tandem mass spectrometry (GC-MS/MS) conditions were optimized for detecting biological indicators in e-cigarette products. Nine tobacco-related alkaloids were identified and selected as biological indicators for TDN. A liquid-liquid extraction and GC-MS/MS quantitative method were developed to detect nine biological indicators in e-cigarette products with the limit of quantification ranging from 0.2 to 4.2 µg L-1 using 0.5 mL of e-liquid. This method was applied to 50 e-cigarette brands purchased in the Korean market. The developed method was able to easily and accurately identify the origin of nicotine even using a small amount of e-liquid sample. It is expected that effective e-cigarette regulation will be possible if the nicotine biological indicator and high-sensitivity analysis method developed in this study are used.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nicotina , Nicotina/análise , Biomarcadores Ambientais , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas
3.
Environ Monit Assess ; 194(4): 268, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35266055

RESUMO

The simultaneous determination of 8 polychlorinated biphenyls (PCBs), 23 organic chlorine pesticides (OCPs), and 35 polycyclic aromatic hydrocarbons (PAHs) in black-tailed gull eggs was described using ultrasound-assisted extraction and gas chromatography-tandem mass spectrometry (GC-MS/MS). The ranges of the lower limits of detection for PCBs, OCPs, and PAHs were 0.006-0.029, 0.01-0.10, and 0.01-0.20 µg kg-1, respectively. The intraday precision was in the range of 0.650-12.9% and the intraday accuracy was in the range of 86.6-113%. When the proposed method was used to analyze the target compounds in gull eggs collected from six sites in the Republic of Korea, the analytical results demonstrated concentration ranges of 113.32-394.07 µg kg-1 for total PCBs, 422.92-1082.09 µg kg-1 for total OCPs, and 134.50-231.27 µg kg-1 for total PAHs in the samples. The PCA results for PAHs and OCPs were well differentiated by sampling site, whereas those for PCBs differed little by sampling site. There were more pyrogenic PAHs in the West Sea and the South Sea with many industrial areas than in the East Sea with few industrial areas. Differences in the OCP patterns of samples from the West Sea close to China were considered to be related to the use of DDT in China until recently. PCBs were accumulated in the samples regardless of region, so there was no significant difference in the PCB patterns between the samples obtained from the three Seas.


Assuntos
Charadriiformes , Hidrocarbonetos Clorados , Praguicidas , Bifenilos Policlorados , Hidrocarbonetos Policíclicos Aromáticos , Animais , Cloro/análise , Monitoramento Ambiental , Cromatografia Gasosa-Espectrometria de Massas , Hidrocarbonetos Clorados/análise , Praguicidas/análise , Bifenilos Policlorados/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Espectrometria de Massas em Tandem
4.
Environ Sci Pollut Res Int ; 29(3): 3930-3943, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34396474

RESUMO

Approximately 99.1% of South Koreans have access to drinkable tap water from river basins. Due to such a high access rate, the South Korean government has been running, since 2013, a long-term program for monitoring the quality of tap water for drinking. Under this program, the maximum allowed concentrations of N-nitroso-di-n-methylamine (NDMA) and N-nitrosomethylethylamine (NMEA) are defined and applied. In this study, the data from this monitoring program were used to investigate the changes in six N-nitrosamine substances in the finished water of 33 drinking water treatment plants (DWTPs) in South Korea from 2013 to 2020, based on time and location. The effect of the applied water treatment steps on the appearance of N-nitrosamines was analyzed. The excess cancer risk (ECR) due to the oral intake of these substances was assessed. The results before the maximum allowed concentrations of NDMA and NMEA were defined showed that the oral intake ECR of these substances exceeded the carcinogenesis risk of one per one million people per year. After the maximum allowed concentrations of the substances were applied, the concentrations of the substances in the finished water of the DWTPs significantly dropped. The drinking water treated through sand filtration, and then with granular activated carbon, showed the highest efficiency in preventing the appearance of NDMA. Considering the potency of N-nitrosamines in tap water for drinking, the levels of these substances in the finished water of DWTPs in South Korea should be continuously monitored.


Assuntos
Água Potável , Nitrosaminas , Poluentes Químicos da Água , Purificação da Água , Humanos , Nitrosaminas/análise , Medição de Risco , Poluentes Químicos da Água/análise
5.
J Pharm Biomed Anal ; 189: 113460, 2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-32663759

RESUMO

N-Nitrosodimethylamine (NDMA) has been detected in some drug substance and drug products containing sartans, ranitidine and metformin. N-nitrosodiethylamine (NDEA) has also been found to be present in some sartan medications. A method for the simultaneous detection of NDMA and NDEA in drug substances and finished products of sartans, metformin and ranitidine has been optimized using isotope dilution, clean-up procedure and gas chromatography-tandem mass spectrometry (GC-MS/MS). The purification of drug substances and excipients was efficient when utilizing precipitation and activated charcoal cartridges. Most of irbesartan, pimasartan, olmesartan, and candesartan were removed by precipitation using solubility difference, while valsartan, rosartan, metformin and ranitidine were completely removed after activated charcoal purification. Even when the extracts were injected in GC-MS/MS more than 100 times, the peak shape and sensitivity did not change, and no peak interference occurred. When a 0.10 g sample was used, the range of the lower limit of detection was 0.07-0.3 µg/kg, and the range of the lower limit of quantification was 0.3-0.9 µg/kg. The precision was in the range of 0.4-2.7 % for NDMA and 0.4-4.2 % for NDEA, and the accuracy was in the range of 95.0-105 % for NDMA and 93.6-104 % for NDEA. NDMA was detected with a concentration of 0.004 mg/kg in a valsartan and 0.012 mg/kg in a ranitidine, and NDEA was detected at concentrations of 0.009 and 0.008 mg/kg in irbesartan and rosartan. Otherwise, NDMA was detected at a concentration of 0.062 mg/kg in a fimasartan product and 0.009 mg/kg in a ranitidine product. This method is available for all drug substances and finished products of sartans; metformin and ranitidine.


Assuntos
Metformina , Preparações Farmacêuticas , Bloqueadores do Receptor Tipo 1 de Angiotensina II , Dimetilnitrosamina/análogos & derivados , Dimetilnitrosamina/análise , Cromatografia Gasosa-Espectrometria de Massas , Ranitidina , Extração em Fase Sólida , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS