Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 37(2): 387-391, 2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-32963199

RESUMO

Chromium oxide(VI), (Cr(VI)) has been used in gas detector tubes as an indicator to detect alcohols. However, it is toxic and regulated to prevent environmental pollution. In this report, potassium manganate(VII) was chosen instead of Cr(VI). A samples of 100 mL of ethanol, methanol and 2-propanol vapors were passed through a gas detector tube with an aspirating pump. Sampling time was 3 min. The stain length on the tube was in the range of 20 - 300 ppm. A novel detector tube for alcohols was developed without Cr(VI).

2.
J Occup Health ; 62(1): e12105, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31883172

RESUMO

OBJECTIVES: The purpose of this research was to develop and validate an analytical method for rapid determination of the exposure of workers to ortho-phthalaldehyde (OPA) at the ceiling threshold concentration. METHODS: A 2,4-dinitrophenylhydrazine (DNPH)-silica cartridge was chosen as a sampler. OPA collected by the DNPH-silica cartridge was subsequently extracted with 5 mL of acetonitrile. A 50-µL aliquot of phosphoric acid/acetonitrile solution (2%, v/v) was added to 950 µL of the extraction solution and allowed to stand for 30 minutes at room temperature. This solution was then analyzed by high-performance liquid chromatography tandem mass spectrometry. The basic characteristics of the proposed method, such as recovery, repeatability, limit of quantification, and storage stability of the samples, were examined. RESULTS: The overall recoveries of OPA from OPA-spiked DNPH-silica cartridges were 93.6%-100.1% with relative standard deviations, representing the repeatability, of 1.5%-10.8%. The limit of quantification was 0.165 ng/sample. The recovery of OPA from DNPH-silica cartridges after 5 days of storage in a refrigerator exceeded 95%. CONCLUSIONS: The proposed method enabled the determination of the OPA concentration corresponding to the Threshold Limit Value-Ceiling of 0.1 ppb recommended by the American Conference of Governmental Industrial Hygienists, with a minimum sampling time of 18 seconds (corresponding to a sampling volume of 300 mL at 25°C and 1 atm). Thus, this method will be useful for estimating worker exposures to OPA.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Exposição Ocupacional/análise , Níveis Máximos Permitidos , o-Ftalaldeído/análise , Cromatografia Líquida de Alta Pressão , Humanos , Espectrometria de Massas , Estrutura Molecular , Fenil-Hidrazinas , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...