Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 24(2): 267-71, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18270421

RESUMO

A 5-amino-8-hydroxyquinoline (AHQ)-modified gold nanoparticle (GNP) layer was fabricated on an inner wall of a silica capillary column by alternatively passing a citrate-stabilized GNP solution and an AHQ solution in a repeating fashion. The observations by a field emission scanning electron microscope showed that the thickness of the resulting GNP layer was about 0.15 microm. This column was then used as an open tubular solid-phase extraction column for cadmium, followed by electrothermal atomic absorption spectrometric determination. The detection limit of 0.009 ng ml(-1) was obtained.


Assuntos
Cádmio/análise , Ouro/química , Hidroxiquinolinas/química , Nanopartículas Metálicas/química , Extração em Fase Sólida/métodos , Concentração de Íons de Hidrogênio , Íons/análise , Microscopia Eletrônica de Varredura/métodos , Tamanho da Partícula , Sensibilidade e Especificidade , Dióxido de Silício/química , Soluções/química , Espectrofotometria Atômica/métodos , Propriedades de Superfície
2.
Anal Sci ; 23(12): 1435-8, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18071232

RESUMO

A resin-phase extraction method has been optimized for the trace determination of tin(II) by ETAAS. Tin(II) was extracted on a finely divided anion exchange resin as the complex with ammonium pyrrolidinedithiocarbamate (APDC). The resin was collected on a membrane filter and then dispersed in 1.00 ml of 1 mol l(-1) nitric acid containing 100 microg of Pd(II) and 60 microg of Ni(II). The resulting resin suspension was subjected to GFAAS. The proposed method was applied to the determination of tin(II) in hydrochloric acid.

3.
Anal Sci ; 20(7): 1033-6, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15293397

RESUMO

Cellulose derivative resin (CDR) suspensions containing resin particles of cellulose nitrate (CDR(CN)), cellulose acetate (CDR(CA)), or cellulose triacetate (CDR(CTA)) were prepared as the sorbent for resin suspension injection (RSI) electrothermal atomic absorption spectrometry (ETAAS), in which fine resin particles holding a desired trace element were directly injected into the graphite tube as the suspension. To compare the sorption ability, the distribution ratios of the Mo(VI)-phenylfluorone complex were measured between the aqueous phase and the sorbents, including the CDRs mentioned above and the finely divided anion exchange resin (AR). The results showed that the sorption ability decreases in the following order: CDR(CN) > or = AR > CDR(CA) > or = CDR(CTA). It was concluded that CDR(CN) was able to extract more than 98% of Mo(VI), and was suitable for RSI-ETAAS as well as AR. CDR(CN) was used for the determination of Mo in NIES certified reference materials, No. 10 Rice flour-unpolished; the results showed fairly good agreements between the analytical values and the certified values.

4.
J AOAC Int ; 87(4): 986-90, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15295894

RESUMO

Thallium in potassium chloride and electrolyte replenishers was determined by electrothermal atomic absorption spectrometry (ETAAS) with direct injection of a resin suspension. Thallium(III) was extracted on fine particles of a cellulose nitrate resin (CNR) from dilute HCl (pH 1.6) in the presence of ammonium pyrrolidine-1-carbodithioate. The CNR particles were collected on a membrane filter by filtration under suction, suspended in 1.0 mL 10mM HNO3, and then delivered directly to ETAAS as the suspension. The effects of chloride ions were thoroughly investigated. The results showed that the addition of 0.5mM NaCl to the suspension (10mM HNO3) was recommended, after CNR and a membrane filter holding the CNR were washed thoroughly with 0.025M HCl, to eliminate interference from chloride ions. No chemical modifier was required. Extraction from the solution containing up to 2M chloride ion was allowable. The proposed method gave a concentration factor of 50 for a 50 mL sample volume. The detection limit (3sigma, n = 5) was 1 ng (20 pg/mL). The relative standard deviation was 4.9% (n = 5) at 30 ng level of thallium. The content of thallium in potassium chloride was 15.7-32.8 ng/g, and in electrolyte replenishers was 0.18-4.16 ng/mL.


Assuntos
Cloreto de Potássio/análise , Soluções para Reidratação/análise , Tálio/análise , Calibragem , Filtração , Indicadores e Reagentes , Chumbo/análise , Reprodutibilidade dos Testes , Soluções , Espectrofotometria Atômica , Ultrassom
5.
Anal Sci ; 19(10): 1353-4, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14596396

RESUMO

8-Hydroxyquinoline derivative 1 as a fluorescent chemosensor for Zn2+ was synthesized. Because Cd2+ is often found with Zn2+ in the environment and can form fluorescent complexes with chelating fluorophores, a potentially important property of chemosensors for Zn2+ is their selectivity for Zn2+ over Cd2+. The Zn2+ or Cd2+ complexes of 1 gave an emission band from the 1:1 complex, but the fluorescence intensity for Cd2+ was a half of that for Zn2+. Ligand 1 is suited for use as a fluorescent chemosensor for Zn2+.


Assuntos
Oxiquinolina/análogos & derivados , Zinco/análise , Estrutura Molecular , Oxiquinolina/química , Espectrometria de Fluorescência , Análise Espectral
6.
Anal Sci ; 18(9): 1009-14, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12243395

RESUMO

The changes in the oxidation state of vanadium in artificial and natural seawater samples were studied by electrothermal atomic absorption spectrometry (ETAAS) with a direct injection of a resin suspension. V(IV) and V(V) were extracted as the complex with Chromazurol B and with N-cinnamoyl-N-2,3-xylylhydroxylamine, respectively, using a suspension of an anion-exchange resin and determined by ETAAS independently. The detection limits of both methods were 0.02 ng ml(-1) for 40 ml of a sample solution. The recovery tests for an artificial seawater sample spiked with V(IV) and/or V(V) were carried out carefully. The results showed that the recoveries of V(IV) or V(V) were 99.2-109% and the standard deviations were 1-6%. The total V was also determined after V(V) was reduced by ascorbic acid. In artificial seawater at pH 7.8, V(V) was stable but V(IV) was oxidized rapidly. In acidified artificial seawater (pH 2.0), V(IV) was oxidized slowly but only a small tendency of such reduction of V(V) was observed. In a natural seawater sample, V(IV) was not detected. The acidification of the natural seawater sample resulted in the reduction of V(V).


Assuntos
Água do Mar/química , Manejo de Espécimes , Espectrofotometria Atômica/métodos , Vanádio/análise , Vanádio/química , Concentração de Íons de Hidrogênio , Oxirredução , Sensibilidade e Especificidade , Compostos de Vanádio/análise , Compostos de Vanádio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...