Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Neurol ; 15: 1346099, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38352137

RESUMO

Purpose: Although exercise is recommended for cancer survivors with chemotherapy-induced peripheral neuropathy (CIPN), the effective types of exercise for preventing and treating CIPN remain unclear. This systematic review and network meta-analysis (NMA) aimed to evaluate the comparative effects of exercise on CIPN. Methods: We included relevant randomized controlled trials (RCTs) identified in a 2019 systematic review that evaluated the effects of exercise on CIPN and conducted an additional search for RCTs published until 2023. We evaluated the risk of bias for each RCT; the comparative effectiveness of exercise on patient-reported quality of life (QOL) through an NMA; and the effectiveness of exercise on QOL scores, patient-reported CIPN symptoms, and pain through additional meta-analyses. Results: Twelve studies (exercise, n = 540; control, n = 527) comparing 8 exercise interventions were included in the analysis. All studies were determined to have a high risk of bias. The meta-analyses showed significantly improved QOL [standard mean differences (SMD) 0.45; 95% confidence interval (CI) = 0.12 to 0.78] and CIPN symptoms (SMD 0.46; 95% CI = 0.11 to 0.82). No severe adverse events were reported. Pain tended to improve with exercise (SMD 0.84; 95% CI = -0.11 to 1.80). An NMA suggested that the interventions of a combination of balance and strength training showed a significant improvement in QOL scores compared to the control. Conclusion: Exercise interventions may be beneficial for improving QOL and CIPN symptoms. High-quality large clinical trials and data are needed to conclude that exercise is beneficial and safe.

2.
Asian J Anesthesiol ; 57(3): 85-92, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31722470

RESUMO

Objective: Perioperative intravascular volume can be optimised by identifying predictors of fluid responsiveness. This study compared the estimated continuous cardiac output (esCCO) system for non- invasive measurement and an arterial pressure-based cardiac output (APCO) system for detecting exact changes in cardiac output (CO) among patients undergoing laparotomy without postural change. Methods: This study was performed at Toho University Omori Medical Centre in Japan from April 2016 to July 2016 and included 26 adult patients undergoing elective laparotomy lasting > 2 h without postural change. We evaluated both interchangeability and dynamic trend. After entering the biometric data (age, sex, height, weight, heart rate, pulse wave transit time, and blood pressure), the esCCO device was calibrated. All patients were also monitored with the APCO system. Data were analysed and compared for 12 adult patients using Bland­Altman analysis and polar plots. Results: The CO value obtained with esCCO was 0.75 ± 0.86 L/min (percentage error: 41%) lower than that obtained with the APCO system. Polar plotting revealed that the mean angular bias was 3.5°, and the radial limit of agreement was 28.3°. Conclusion: This study demonstrated that data obtained using esCCO are not interchangeable with those obtained using the APCO system. The trending ability of the esCCO device was deemed good among patients undergoing laparotomy without postural change.


Assuntos
Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia , Laparotomia , Análise de Onda de Pulso , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura
3.
J Clin Monit Comput ; 30(5): 621-7, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26370094

RESUMO

Estimated continuous cardiac output (esCCO), a noninvasive technique for continuously measuring cardiac output (CO), is based on modified pulse wave transit time, which in turn is determined by pulse oximetry and electrocardiography. However, its trending ability has never been evaluated in patients undergoing non-cardiac surgery. Therefore, this study examined esCCO's ability to detect the exact changes in CO, compared with currently available arterial waveform analysis methods, in patients undergoing kidney transplantation. CO was measured using an esCCO system and arterial pressure-based CO (APCO), and compared with a corresponding intermittent bolus thermodilution CO (ICO) method. Percentage error and statistical methods, including concordance analysis and polar plot analysis, were used to analyze results from 15 adult patients. The difference in the CO values between esCCO and ICO was -0.39 ± 1.15 L min(-1) (percentage error, 35.6 %). And corrected precision for repeated measures was 1.16 L min(-1) (percentage error for repeated measures, 36.0 %). A concordance analysis showed that the concordance rate was 93.1 %. The mean angular bias was -1.8° and the radial limits of agreement were ±37.6°. The difference between the APCO and ICO CO values was 0.04 ± 1.37 L min(-1) (percentage error, 42.4 %). And corrected precision for repeated measures was 1.37 L min(-1) (percentage error for repeated measures, 42.5 %). The concordance rate was 89.7 %, with a mean angular bias of -3.3° and radial limits of agreement of ±42.2°. This study demonstrated that the trending ability of the esCCO system is not clinically acceptable, as judged by polar plots analysis; however, its trending ability is clinically acceptable based on a concordance analysis, and is comparable with currently available arterial waveform analysis methods.


Assuntos
Pressão Arterial , Débito Cardíaco , Cardiologia/instrumentação , Monitorização Fisiológica/métodos , Adulto , Idoso , Anestesia Epidural/métodos , Artérias/patologia , Pressão Sanguínea , Dióxido de Carbono/química , Cateterismo , Eletrocardiografia/métodos , Feminino , Hidratação , Insuficiência Cardíaca/complicações , Frequência Cardíaca , Humanos , Transplante de Rim , Masculino , Pessoa de Meia-Idade , Oximetria/métodos , Artéria Pulmonar/patologia , Pulso Arterial , Insuficiência Renal/complicações , Insuficiência Renal/cirurgia , Reprodutibilidade dos Testes , Volume de Ventilação Pulmonar , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...