Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Gastrointestin Liver Dis ; 17(2): 173-8, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18568138

RESUMO

INTRODUCTION: Staging and restaging of pancreatic malignancy can be demanding. Often, there are liver lesions seen on diagnostic CT suspicious for secondary deposits. Positron emission tomography (PET)-CT may have a great potential in confirming or ruling out actual malignancy in those areas. METHODS: We prospectively studied 12 pancreatic adenocarcinoma patients, who had undergone PET-CT imaging as part of their staging or restaging process. Imaging was performed after intravenous administration of 10 mCi F-18 FDG. Results were compared with CT, histopathological findings and/or clinical follow up. RESULTS: PET-CT correctly identified 11 lesions and ruled the absence of disease in 4 out of 4 patients (PPV 92%, NPV of 100%, and accuracy 94%), compared to CT which had (PPV 79%, NPV 50% and accuracy 75%). CT identified 4 metastatic liver lesions in 12 patients of which 3 were actually benign processes. CONCLUSION: FDG-PET detects pancreatic malignancy and metastatic disease with higher accuracy than conventional CT. The ability of PET-CT to rule out or correctly identify metastases greatly enhances the physician's decision-making process to choose the right therapeutic intervention.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Pancreáticas/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Biópsia por Agulha Fina , Diagnóstico Diferencial , Endossonografia , Feminino , Fluordesoxiglucose F18/administração & dosagem , Seguimentos , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Estadiamento de Neoplasias , Neoplasias Pancreáticas/secundário , Projetos Piloto , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
2.
Ann Neurol ; 64(1): 35-41, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18570291

RESUMO

OBJECTIVE: To gain information on the value of magnetic source imaging (MSI), 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET), and ictal single photon emission computed tomography (SPECT) to predict seizure-free outcome following epilepsy surgery in patients who require intracranial electroencephalography (ICEEG). METHODS: This work was part of a prospective observation study of epilepsy surgery candidates not sufficiently localized with scalp EEG and MRI. Of 160 patients enrolled 62 completed ICEEG and subsequent surgical resection. Sixty-one percent resulted in an Engel I seizure-free outcome at a minimum of one-year follow-up (mean = 3.4 years). Sensitivity, specificity, and predictive values were computed for each modality. Multivariate logistical regression was used to identify prediction of surgical outcome by imaging test. RESULTS: MSI sensitivity for a conclusively localized study was 55% with a positive predictive value of 78%. Eliminating non-diagnostic MSI cases (no spikes captured during recording) yielded a corrected negative predictive value of 64%. With available comparison subgroups FDG-PET and ictal SPECT values were similar to MSI. The OR (adjusted for epilepsy and MRI classification) for MSI prediction of seizure-free outcome was 4.4 (p =0.01). In cases with both PET and MSI, the adjusted OR for PET was 7.1 (p <0.01) and for MSI was 6.4 (p = 0.01). In the cases with all three tests (n = 27), ictal SPECT had the highest OR of 9.1 (p = 0.05). INTERPRETATION: MSI, FDG-PET, and ictal SPECT each have clinical value in predicting seizure-free surgical outcome in epilepsy surgery candidates who typically require ICEEG.


Assuntos
Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Tomografia por Emissão de Pósitrons/métodos , Cuidados Pré-Operatórios/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Encéfalo/cirurgia , Criança , Pré-Escolar , Estudos de Coortes , Técnicas de Apoio para a Decisão , Eletroencefalografia/métodos , Eletroencefalografia/normas , Epilepsia/fisiopatologia , Feminino , Fluordesoxiglucose F18 , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Tomografia por Emissão de Pósitrons/normas , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/normas , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/normas , Resultado do Tratamento
3.
Ann Neurol ; 64(1): 25-34, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18412264

RESUMO

OBJECTIVE: To gain information on the predictive and prognostic value of magnetic source imaging (MSI), 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography ((18)FDG-PET), and ictal single-photon emission computed tomography (SPECT) as compared with intracranial electroencephalography (ICEEG) localization in epilepsy surgery. METHODS: This work was part of a cohort study of epilepsy surgery candidates not sufficiently localized with noninvasive studies. Of 160 patients enrolled over 4 years, 77 completed ICEEG seizure monitoring. Sensitivity, specificity, and predictive values relative to ICEEG were computed for each modality. RESULTS: Seizures were not captured in five patients. Of the 72 diagnostic ICEEG studies, seizure localization results were 74% localized, 10% multifocal, and 17% nonlocalized. Sixty-one percent were localized to neocortical regions. Depending on patient subgroup pairs, sensitivity ranged from 58 to 64% (MSI), 22 to 40% (PET), and 39 to 48% (SPECT); specificity ranges were 79 to 88% (MSI), 53 to 63% (PET), and 44 to 50% (SPECT). Gains in diagnostic yield were seen only with the combination of MSI and PET or MSI and ictal SPECT. Localization concordance with ICEEG was greatest with MSI, but a significant difference was demonstrated only between MSI and PET. Moderate redundancy was seen between PET and ictal SPECT (kappa = 0.452; p = 0.011). INTERPRETATION: Conclusively positive MSI has a high predictive value for seizures localized with ICEEG. Diagnostic gain may be achieved with addition of either PET or ictal SPECT to MSI. Diagnostic values for imaging tests are lower than "true values" because of the limitations of ICEEG as a gold standard.


Assuntos
Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Encéfalo/fisiopatologia , Mapeamento Encefálico/instrumentação , Mapeamento Encefálico/métodos , Estudos de Coortes , Eletroencefalografia/normas , Epilepsia/fisiopatologia , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/normas , Tomografia por Emissão de Pósitrons/normas , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/normas , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/normas
4.
Health Phys ; 92(2 Suppl): S45-9, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17228187

RESUMO

Iodine ablation therapy for thyroid cancer on patients receiving dialysis poses unique radiation safety challenges. Exposure to gamma and beta negative particles by the hemodialysis (HD) staff is a concern that has not been well studied. A 53-y-old male patient on HD for chronic renal failure was scheduled for 131I high dose therapy as treatment for thyroid papillary carcinoma. The patient was on HD every other day, prior to ablation. A high dose of 131I (3,607.5 MBq) was required. The patient was admitted for 131I therapy, and continued HD. Thyroid cancer ablation therapy was administered according to our institutional protocol. New radiation safety measures were developed and implemented in order to give the patient an optimal treatment dose, reduce radiation to the patient (critical organs and whole body), and to protect the HD personnel. This included placing two lead shields between the patient and the HD nurse, and HD monitoring by two alternating nurses to reduce their radiation exposure. Film badges were used to measure radiation exposure to the nursing staff. Dosimetry calculations were obtained to determine radiation absorbed doses by the optic lens, skin, and whole body. Quality control verification for this shielding arrangement proved to be effective in protecting the HD staff against gamma and beta negative radiation from recent 131I high dose therapy. Implementation of this model proved to be an effective and adequate radiation safety protocol for limiting radiation exposure to the HD staff. The patient was given 3607.5 MBq for optimal treatment after HD. Hemodialysis was repeated after approximately 48 and 96 h to remove excess 131I and reduce radiation to the patient.


Assuntos
Carcinoma Papilar/radioterapia , Falência Renal Crônica/complicações , Proteção Radiológica , Neoplasias da Glândula Tireoide/radioterapia , Carcinoma Papilar/complicações , Humanos , Radioisótopos do Iodo , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Diálise Renal , Neoplasias da Glândula Tireoide/complicações
6.
Ann Thorac Surg ; 82(2): 417-22; discussion 422-3, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16863739

RESUMO

BACKGROUND: Positron emission tomography (PET) scans often help direct biopsies of mediastinal lymph nodes in patients with non-small cell lung cancer (NSCLC), but the maximum standard uptake value (maxSUV) of individual nodes has not been evaluated. METHODS: This is a prospective study of consecutive patients with NSCLC, all of whom underwent integrated fluorodeoxyglucose-positron emission-computed tomography (FDG-PET-CT) and had biopsy or resection of their mediastinal lymph nodes. RESULTS: There were 397 patients. One-hundred and forty-three patients had N2 disease and 1,252 N2 nodes were pathologically examined. The median maxSUV of the nodes that had metastatic disease were the following: for the 2R node, 10.4 (range, 0-18.6); for 4R, 8.6 (range, 0-18.3); for 5, 8.9 (range, 0-26.3); for 6, 7.6 (range, 0-19.6); for 7, 7.7 (range, 0-14); for 8 and 9, 5.4 (range, 0-8.9). The median maxSUV for all of the N2 nodes that were benign was 0 (range, 0-18.8) (p < 0.05 for all stations except for nodes 8 and 9). When a maxSUV of 5.3 is used the accuracy of integrated FDG-PET-CT for each N2 nodal station is maximized and is at least 92% for each. CONCLUSIONS: The maxSUV of individual mediastinal lymph nodes is a predictor of malignancy. There is overlap between false and true positives. Definitive biopsies are required to prove cancer irrespective of the maxSUV value. However, when a maxSUV of 5.3 is used instead of the traditional value of 2.5, the accuracy for FDG-PET-CT for each N2 nodal station increases to at least 92%.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Linfonodos/patologia , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma Pulmonar de Células não Pequenas/patologia , Erros de Diagnóstico , Feminino , Humanos , Neoplasias Pulmonares/patologia , Metástase Linfática , Masculino , Mediastino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
7.
J Thorac Cardiovasc Surg ; 131(6): 1229-35, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16733150

RESUMO

BACKGROUND: The accuracy of restaging in patients with stage IIIa non-small cell lung cancer after neoadjuvant chemoradiotherapy is unknown. METHODS: A prospective trial of patients with biopsy-proven N2 disease who underwent initial clinical staging with mediastinoscopy, integrated positron emission tomography/computed tomography (PET/CT), and CT. Patients then were clinically restaged by the same imaging techniques 4 to 12 weeks after their induction chemoradiation therapy and then underwent definitive pathologic staging. RESULTS: Ninety-three patients had their lymph nodes pathologically restaged. Repeat PET/CT after neoadjuvant therapy missed residual N2 disease in 13/65 (20%) patients and falsely suggested it in 7 of 28 (25%). It was more accurate than repeat CT for restaging at all pathologic stages (stage 0, 92% vs 39%, P = .03; and stage I 89% vs 36%, P = .04). When the maximum standardized uptake value of the primary tumor is decreased by 75% or more, it is highly likely (likelihood ratio, +LR, 6.1) the patient is a complete responder; when it decreased by 55% or more, it is highly likely (+LR, 9.1) the patient is a partial responder. When the maximum standardized uptake value of the N2 node initially involved with metastatic cancer is decreased by more than 50%, it is highly likely (+LR, 7.9) the node is now benign. CONCLUSION: Repeat integrated PET/CT is superior to repeat CT for the restaging of patients with stage IIIa non-small cell lung cancer. The percent decrease in the maximum standardized uptake value of the primary and of the involved lymph node is predictive of pathology; however, nodal biopsies are required since a persistently high maximum standardized uptake value does not equate to residual cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/terapia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/terapia , Adulto , Idoso , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Quimioterapia Adjuvante , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Radioterapia Adjuvante , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
8.
Ann Thorac Surg ; 80(4): 1207-13; discussion 1213-4, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16181842

RESUMO

BACKGROUND: Clinical stage affects the care of patients with nonsmall cell lung cancer. METHODS: This is a prospective trial on patients with suspected resectable nonsmall cell lung cancer. All patients underwent integrated positron emission tomographic scanning and computed tomographic scanning, and all suspicious metastatic sites were investigated. A, T, N, and M status was assigned. If N2, N3 and M1 were negative, patients underwent thoracotomy and complete thoracic lymphadenectomy. RESULTS: There were 383 patients. The accuracy of clinical staging using positron emission tomographic scanning and computed tomographic scanning was 68% and 66% for stage I, 84% and 82% for stage II, 74% and 69% for stage III, and 93% and 92% for stage IV, respectively. N2 disease was discovered in 115 patients (30%) and was most common in the subcarinal lymph node (30%). Unsuspected N2 disease occurred in 28 patients (14%) and was most common in the posterior mediastinal lymph nodes (subcarinal, 38%; posterior aortopulmonary, 15%). It was found in 9% of patients who were clinically staged I (58% in the posterior mediastinal lymph nodes) and in 26% of patients clinically staged II (86% in posterior mediastinal lymph nodes). CONCLUSIONS: Despite integrated positron emission tomographic scanning and computed tomographic scanning, clinical staging remains relatively inaccurate for patients with nonsmall cell lung cancer. Recent studies suggest adjuvant therapy for stage Ib and II nonsmall cell lung cancer; thus the impact on preoperative care is to find unsuspected N2 disease. Unsuspected N2 disease is most common in posterior mediastinal lymph nodes inaccessible by mediastinoscopy. Thus one should consider endoscopic ultrasound fine-needle aspiration, especially for patients clinically staged as I and II, even if the nodes are negative on positron emission tomographic scanning and computed tomographic scanning.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias/métodos , Estadiamento de Neoplasias/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Valores de Referência , Sensibilidade e Especificidade , Toracoscopia/métodos , Ultrassonografia
9.
Ann Thorac Surg ; 79(1): 263-8, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15620955

RESUMO

BACKGROUND: The treatment of patients with non-small cell lung cancer (NSCLC) depends on the stage. Positron emission and computed tomography (CT) scans can identify suspicious lymph nodes that require biopsy. We prospectively evaluated the yield and accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) in sampling mediastinal lymph nodes and compared its accuracy to that of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) and CT in staging NSCLC. METHODS: A consecutive series of patients with suspicious nodes on PET or CT scan in the posterior mediastinal lymph node stations (#5, 7, 8, or 9) were prospectively evaluated by EUS-FNA. The reference standard included thoracotomy with complete lymphadenectomy in patients with lung cancer or if EUS-FNA was benign, repeat clinical imaging, or long-term follow-up. RESULTS: There were 104 patients (63 men) with 125 lesions (117 lymph nodes, 8 left adrenal glands) who underwent EUS-FNA. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EUS-FNA were 92.5%, 100%, 100%, 94%, and 97%, respectively. EUS-FNA was more accurate and had a higher positive predictive value than the PET or CT (p < 0.001) scan in confirming cancer in the posterior mediastinal lymph nodes. EUS-FNA documented metastatic cancer to the left adrenal in all 4 patients with advanced disease. No deaths resulted from EUS-FNA. One patient experienced self-limited stridor. CONCLUSIONS: EUS-FNA is a safe, accurate, and minimally invasive technique that improves the staging of patients with NSCLC. It is more accurate and has a higher predictive value than either the PET scan or CT scan for posterior mediastinal lymph nodes.


Assuntos
Biópsia por Agulha Fina , Carcinoma Pulmonar de Células não Pequenas/secundário , Esofagoscopia , Neoplasias Pulmonares/patologia , Doenças Linfáticas/patologia , Metástase Linfática/patologia , Estadiamento de Neoplasias/métodos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção , Idoso , Neoplasias da Mama/patologia , Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Carcinoma/secundário , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Neoplasias do Colo/patologia , Neoplasias do Endométrio/patologia , Feminino , Fluordesoxiglucose F18 , Granuloma/diagnóstico , Histiocitose/complicações , Histiocitose/diagnóstico , Histoplasmose/complicações , Histoplasmose/diagnóstico , Humanos , Neoplasias Renais/patologia , Pneumopatias/complicações , Neoplasias Pulmonares/diagnóstico , Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/etiologia , Metástase Linfática/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Linfoma/patologia , Masculino , Mediastino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sarcoidose/complicações , Sarcoidose/diagnóstico , Silicose/complicações , Silicose/diagnóstico , Neoplasias da Bexiga Urinária/patologia
12.
Ann Thorac Surg ; 76(3): 861-6, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12963217

RESUMO

BACKGROUND: To assess the role of flourodeoxyglucose-positron-emission tomography (FDG-PET) scan in staging patients with nonsmall cell lung cancer (NSCLC). METHODS: We prospectively studied 400 patients with NSCLC. Each patient underwent a computed tomography (CT) scan of the chest and upper abdomen, other conventional staging studies and had a FDG-PET scan within 1 month before surgery. All suspicious N2 lymph nodes by either chest CT or by FDG-PET scan were biopsied. Patients that were N2 and M1 negative underwent pulmonary resection and complete thoracic lymphadenectomy. RESULTS: The FDG-PET had a higher sensitivity (71% vs 43%, p < 0.001), positive predictive value (44% vs 31%, p < 0.001), negative predictive value (91% vs 84%, p = 0.006), and accuracy (76% vs 68%, p = 0.037) than CT scan for N2 lymph nodes. Similarly, FDG-PET had a higher sensitivity (67% vs 41%, p < 0.001), but lower specificity (78% vs 88%, p = 0.009) than CT scan for N1 lymph nodes. FDG-PET led to unnecessary mediastinoscopy in 38 patients. FDG-PET was most commonly falsely negative in the subcarinal (#7) station and the aortopulmonary window lymph node (#5, #6) stations. It accurately upstaged 28 patients (7%) with unsuspected metastasis and it accurately downstaged 23 patients (6%). CONCLUSIONS: The FDG-PET scan allows for improved patient selection. It more accurately stages the mediastinum, however there are many false positives lymph nodes and it may be more likely to miss N2 disease in the #5, #6, and #7 stations. A positive FDG-PET scan means a tissue biopsy is indicated in that location.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/secundário , Feminino , Humanos , Neoplasias Pulmonares/patologia , Metástase Linfática , Masculino , Mediastinoscopia , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Thorac Cardiovasc Surg ; 125(4): 938-44, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12698159

RESUMO

OBJECTIVES: Surgical resection after preoperative chemotherapy in patients with non-small cell lung cancer might only be best for patients who are responders. We compared positron emission tomographic scanning with 2-fluoro-2-deoxy-d-glucose (FDP-PET scanning) with computed tomographic scanning to evaluate their ability to predict this response for the primary tumor, N1 and N2 lymph nodes. METHODS: All patients with non-small cell lung cancer who had an initial FDP-PET scan staging with tissue biopsy, neoadjuvant chemotherapy, repeat FDP-PET scanning, and repeat biopsies were prospectively studied. RESULTS: There were 34 patients (24 men; median age, 64 years). Eleven patients had N2 disease, and 7 had N1 disease. Twenty-seven patients received chemotherapy, and 7 patients received chemotherapy and radiation. All but 9 patients underwent resection. Statistical analysis showed FDP-PET scanning to be more specific (P <.0001), to have a higher positive predictive value (P =.0018), and to have a higher negative predictive value (P <.0001) than computed tomographic scanning for predicting residual tumor at the primary site. FDP-PET scanning was more sensitive (P <.0001) and more accurate (P <.0001), had a higher positive predictive value (P <.0001), and had a higher negative predictive value (P =.0002) than computed tomographic scanning for paratracheal nodes (number 2 and 4 lymph nodes). FDP-PET scanning had a higher positive predictive value (P <.0001) than computed tomographic scanning for the other N2 (numbers 5, 6, 7, 8, and 9) lymph nodes. CONCLUSIONS: Repeat FDP-PET scanning is more specific and has a higher positive predictive value and negative predictive value than computed tomographic scanning for detecting residual tumor in the lung in patients with non-small cell lung cancer who have received preoperative chemotherapy. It is more sensitive and accurate for paratracheal N2 nodes as well. However, there is no significant difference in its detection of N1 lymph nodes.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Adulto , Idoso , Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Quimioterapia Adjuvante , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia Computadorizada por Raios X
15.
Clin Nucl Med ; 27(9): 638-40, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12192281

RESUMO

Ga-67 citrate scintigraphy and computer tomography have been used in tumor staging, to determine disease extent, and for the pre- and post-therapeutic management of Hodgkin's and non-Hodgkin's lymphoma. Today, localization of hypermetabolic tissue using F-18 FDG is beginning to play a role in the staging and restaging of lymphoma. The authors report a case of recurrent Hodgkin's lymphoma in a 31-year-old man detected by F-18 FDG. Findings of the Ga-67 citrate scintigram were negative. Palpable right axillary adenopathy was found on routine physical examination follow-up. Comparison with previous negative findings obtained with Ga-67 citrate was unchanged. However, computed tomography revealed new right axilla lymphadenopathy, prompting further investigation with F-18 FDG SPECT, which showed hypermetabolic activity corresponding to the region of the right axilla involvement. Pathologic examination showed changes indicative of interfollicular recurrence of Hodgkin's lymphoma.


Assuntos
Citratos , Fluordesoxiglucose F18 , Gálio , Doença de Hodgkin/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Adulto , Reações Falso-Negativas , Doença de Hodgkin/patologia , Humanos , Linfonodos/patologia , Masculino , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Radiografia , Cintilografia , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...