Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Polymers (Basel) ; 11(2)2019 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-30960233

RESUMO

Herein, lightweight nanocomposite foams with expansion ratios ranging from 2⁻10-fold were fabricated using an isotactic polypropylene (iPP) matrix and cellulose nanofiber (CNF) as the reinforcing agent via core-back foam injection molding (FIM). Both the native and modified CNFs, including the different degrees of substitution (DS) of 0.2 and 0.4, were melt-prepared and used for producing the polypropylene (PP)/CNF composites. Foaming results revealed that the addition of CNF greatly improved the foamability of PP, reaching 2⁻3 orders of magnitude increases in cell density, in comparison to those of the neat iPP foams. Moreover, tensile test results showed that the incorporation of CNF increased the tensile modulus and yield stress of both solid and 2-fold foamed PP, and a greater reinforcing effect was achieved in composites containing modified CNF. In the compression test, PP/CNF composite foams prepared with a DS of 0.4 exhibited dramatic improvements in mechanical performance for 10-fold foams, in comparison to iPP, with increases in the elastic modulus and collapse stress of PP foams of 486% and 468%, respectively. These results demonstrate that CNF is extraordinarily helpful in enhancing the foamability of PP and reinforcing PP foams, which has importance for the development of lightweight polymer composite foams containing a natural nanofiber.

2.
AIDS Res Hum Retroviruses ; 31(3): 318-25, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25469535

RESUMO

To design appropriate antiretroviral therapy regimens and avoid the emergence of human immunodeficiency virus (HIV)-1 variants with reduced susceptibility to antiretroviral drugs, genotypic drug-resistance testing (HIV genotyping) is strongly recommended. To monitor the quality of HIV genotyping in Japan, we performed an external quality assessment (EQA), named the Japanese external quality assessment program, to standardize HIV genotyping (JEQS). To accurately evaluate the quality of HIV genotyping, we employed as reference material (RM) a well-characterized sample, in vitro transcribed RNA (trRNA) that includes the HIV gag-pol sequence, and created a JEQS2010 panel consisting of three single variant and three mixed trRNA samples. All 11 participating laboratories showed high concordance rates (>96%) for the single variant samples. Eight laboratories also showed good rates of detecting minor variants, but three laboratories failed to detect the variants comprising one-half of the sample. These three laboratories used a common primer that had four internal mismatches to the minor trRNA clone. This program showed the usefulness of trRNA as RM, the high quality of HIV genotyping, and extensive interlaboratory variation in the ability to detect minor variants. These results suggest that improving the quality of HIV genotyping in Japan requires regularly implementing the EQA program and improving the HIV genotyping protocol in each laboratory.


Assuntos
Farmacorresistência Viral , Técnicas de Genotipagem/normas , Infecções por HIV/virologia , HIV-1/efeitos dos fármacos , HIV-1/genética , Ensaio de Proficiência Laboratorial/organização & administração , Humanos , Japão , Ensaio de Proficiência Laboratorial/métodos , Testes de Sensibilidade Microbiana/normas
3.
Inflammation ; 35(3): 927-34, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21994180

RESUMO

Methicillin-resistant Staphylococcus aureus (MRSA) with exogenous cassette DNA containing the methicillin-resistant gene mecA (SCCmec) poses a problem as a drug-resistant bacterium responsible for hospital- and community-acquired infections. The frequency of MRSA detection has recently been increasing rapidly in Japan, and SCCmec has also been classified more diversely into types I-V. A rapid test is essential for early diagnosis and treatment of MRSA infections, but detection by conventional methods requires at least two days. The newly developed multiplex PCR lateral flow method allows specific amplification of femA to detect S. aureus, mecA to detect SCCmec, and kdpC to detect SCCmec type II; moreover, PCR products can be evaluated visually in about 3 h. In the present study, we developed a PCR lateral flow method for MRSA using this method and investigated its clinical usefulness in the detection of MRSA. The results showed a diagnostic concordance rate of 91.7% for MRSA and methicillin-susceptible S. aureus between bacteriological examination and PCR lateral flow, and a high level of specificity in PCR lateral flow. In addition, a higher detection rate for S. aureus using the same sample was observed for PCR lateral flow (70.2%) than for bacteriological tests (48.6%). The above results show that PCR lateral flow for MRSA detection has high sensitivity, specificity, and speed, and its clinical application as a method for early diagnosis of MRSA infections appears to be feasible.


Assuntos
Staphylococcus aureus Resistente à Meticilina/genética , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase Multiplex/métodos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Proteínas de Bactérias/genética , Técnicas de Tipagem Bacteriana , DNA Bacteriano/genética , DNA Complementar , Humanos , Proteínas de Ligação às Penicilinas , Proteínas Quinases/genética , Sensibilidade e Especificidade , Infecções Estafilocócicas/genética
4.
Clin Vaccine Immunol ; 16(5): 672-8, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19261775

RESUMO

A novel, rapid, and noninvasive test (ODK0501) to detect Streptococcus pneumoniae antigen was evaluated in a Japanese multicenter study. ODK0501 uses polyclonal antibodies to detect C polysaccharide of S. pneumoniae from sputum samples by an immunochromatographic assay. The utility of ODK0501 was evaluated for 161 adult patients with lower respiratory tract infection between March 2006 and March 2007. Bacterial culture and identification, real-time PCR, and ODK0501 assays were performed on sputum samples, and the Binax Now Streptococcus pneumoniae antigen test was performed using urine samples obtained from the same patients. The performances of all tests were compared based on the results of bacterial culture and identification. The sensitivity and specificity of ODK0501 were 89.1% (49/55 samples) and 95.3% (101/106 samples), respectively. We then compared the Binax Now Streptococcus pneumoniae antigen test with ODK0501 using samples from 142 patients. The sensitivities of ODK0501 and the Binax Now S. pneumoniae antigen test were 90.0% (45/50 samples) and 62.0% (31/50 samples), respectively (P = 0.002). The relative quantity of S. pneumoniae in expectorated sputum was calculated using real-time PCR and indicated that the possibility of false-positive results for ODK0501 due to indigenous S. pneumoniae was low. The positive and negative concordance rates of ODK0501 and Binax Now were 96.8% (30/31 samples) and 21.1% (4/19 samples), respectively. Binax Now was less capable of detecting S. pneumoniae antigen among patients with underlying chronic obstructive pulmonary disease. In conclusion, ODK0501 is noninvasive, rapid, and an accurate tool for diagnosing respiratory infection caused by S. pneumoniae.


Assuntos
Antígenos de Bactérias/análise , Infecções Pneumocócicas/diagnóstico , Infecções Respiratórias/microbiologia , Escarro/química , Streptococcus pneumoniae/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais , Antígenos de Bactérias/imunologia , Feminino , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Polissacarídeos Bacterianos/análise , Polissacarídeos Bacterianos/imunologia , Sensibilidade e Especificidade , Escarro/microbiologia , Streptococcus pneumoniae/química , Urina/química , Adulto Jovem
6.
Jpn J Infect Dis ; 60(2-3): 113-7, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17515643

RESUMO

Highly active antiretroviral therapy (HAART) can suppress human immunodeficiency virus type 1 (HIV-1) replication and plasma HIV-1 to below detectable levels. However, HAART becomes ineffective when drug-resistant viruses emerge during HAART. Monitoring drug-resistance mutations in viruses is necessary for selecting new drugs or therapies effective at inhibiting such HIV-1 variants. Most laboratories in Japan perform the tests using in-house protocols. However, the quality of these tests has never been assessed. Our study assessing the accuracy and reliability of HIV-1 genotypic drug-resistance testing in 15 laboratories in Japan revealed that the quality was very high (97.3% accurate). The errors, though rare, were caused by human errors, poor electropherograms, and the use of inadequate primers. Here, we propose troubleshooting procedures to improve testing accuracy and reliability in Japan.


Assuntos
Terapia Antirretroviral de Alta Atividade , Farmacorresistência Viral/genética , HIV-1/efeitos dos fármacos , HIV-1/genética , Laboratórios/normas , Testes de Sensibilidade Microbiana/normas , Genótipo , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/enzimologia , Humanos , Japão , Testes de Sensibilidade Microbiana/métodos , Controle de Qualidade , RNA Viral/sangue , Reprodutibilidade dos Testes , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...