Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38809376

RESUMO

OBJECTIVES: Zone 2 anastomosis with total cervical branch reconstruction for acute type A aortic dissection and aortic arch aneurysms became possible after stent-graft introduction. This may be an easier procedure and reduce the risk of recurrent laryngeal nerve palsy. Therefore, this study aimed to compare the outcomes between Zone 2 and Zone 3 distal anastomoses. METHODS: After evaluating the patient data in our institute between April 2016 and April 2022, the patients in whom distal anastomosis was performed at Zone 2 with a stent-graft were defined as the Zone 2 group (n = 70). The patients in whom distal anastomosis was performed at Zone 3 were defined as the Zone 3 group (n = 24). RESULTS: The incidence of new-onset recurrent nerve palsy was one patient (1.4%) in the Zone 2 group and six patients (25.0%) in the Zone 3 group (p < 0.001). The lower body perfusion arrest time was 44.3 ± 9.1 min in the Zone 2 group and 52.9 ± 12.8 min in the Zone 3 group (p = 0.005). There were no significant differences in in-hospital mortality and morbidities. Multivariable analysis showed that only age was an independent predictor of overall mortality. CONCLUSIONS: Performing distal anastomosis at Zone 2 with a frozen elephant trunk or stent-graft reduced the lower body perfusion arrest time and possibly prevented recurrent nerve palsy.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38588576

RESUMO

OBJECTIVES: Risk factors for late-term aortic dilation after acute type A aortic dissection repair have not been well examined. The goal of this study was to determine the relationship between the abdominal aortic true lumen location and thoraco-abdominal aortic dilation after surgical repair for acute type A aortic dissection. METHODS: Patients who were preoperatively diagnosed with acute type A aortic dissection between April 2014 and July 2022 were included in this study. We evaluated the renal artery-level dissected aortic morphology and classified the study population into 2 groups: the ventral (those with the true lumen located on the ventral side) and the dorsal (other patients not assigned to the ventral group) groups, based on the location of the true lumen. Aortic dilation was defined as thoraco-abdominal aortic expansion ≥5 mm on 1-year postoperative computed tomography images. RESULTS: We examined 49 surgical patients who were assigned to the ventral (n = 22) and dorsal (n = 27) groups. The number of patients with ≥5 mm thoraco-abdominal aortic dilation after the operation was significantly higher in the ventral group than in the dorsal group (90.9% vs 51.9%, P = 0.009). The multivariable logistic regression analysis showed that the ventral type was an independent prognostic factor for thoraco-abdominal aortic dilation after the operation (odds ratio, 6.01; 95% confidence interval, 1.56-23.77; P = 0.009). CONCLUSIONS: The location of the true lumen of the abdominal aorta in acute type A aortic dissection may be a prognostic factor for thoraco-abdominal aortic dilation after surgical repair.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38637943

RESUMO

We report a case of large left ventricular pseudoaneurysm after inferior acute myocardial infarction. Patch repair is commonly performed; however, only a few studies have described specific surgical techniques for left ventricular pseudoaneurysm repair of the inferior left ventricular wall. As an optimal repair technique for left ventricular pseudoaneurysm of the inferior left ventricular wall is lacking, we believe our technique is safe and effective in repairing this pathology.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38280667

RESUMO

OBJECTIVE: The predissection aortic diameter is the best reference for determining the size of the frozen elephant trunk in aortic dissection. We aimed to develop a new prediction method to estimate the predissection diameter of proximal descending aorta. Furthermore, we evaluated the accuracy of the estimated predissection proximal descending aortic diameters calculated using 3 prediction methods. METHODS: A total of 39 patients with acute type A aortic dissection who underwent predissection computed tomography were included in derivation sets. We measured the aortic dimensions at 3 levels of the proximal descending aorta: 5, 10, and 15 cm from zone 2. We developed a new prediction method-postdissection aortic diameter divided by 1.13 (AoDNew factor)-and estimated the predissection aortic diameter using the new and previously proposed methods by Rylski (AoDRylski) and Yamauchi (EquationYamauchi). Furthermore, we validated the new prediction method using a validation dataset with 24 patients. RESULTS: The rate of bias ≤2 mm was significantly greater with EquationYamauchi and AoDNew factor than with AoDRylski in the derivation group at each level of the proximal descending aorta (P < .001). In the validation group, the rate of bias ≤2 mm was significantly greater with EquationYamauchi and AoDNew factor than with AoDRylski at 10 cm and 15 cm from zone 2 (10 cm: P = .014, 15 cm: P < .001). CONCLUSIONS: These results suggest that the new prediction method can be used as a simple and accurate estimation method for the predissection aortic diameter at the proximal descending aorta.

7.
J Thorac Cardiovasc Surg ; 165(5): 1873-1881.e2, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-34417049

RESUMO

OBJECTIVE: We investigated the efficacy of the Delirium Team Approach program for delirium prevention after cardiovascular surgery. METHODS: We retrospectively investigated 256 patients who underwent cardiac or thoracic vascular surgery between May 2017 and May 2020. We compared the outcomes before and after implementation of the Delirium Team Approach program in December 2018. The program included the following components: (a) educational sessions for the medical team regarding delirium and its management, (b) review of preprinted physician orders for insomnia and agitation, and (c) routine screening for delirium. We investigated the early outcomes and effects of the Delirium Team Approach program on postoperative delirium. RESULTS: The incidence of postoperative delirium significantly decreased from 53.3% to 37.0% after implementation of the Delirium Team Approach program (P = .008). Although no intergroup differences were observed in the rates of stroke and reexploration for bleeding, the length of intensive care unit stay and the overall length of postoperative hospital stay were shorter in the postintervention group. Hospital costs, excluding surgery, and the cost during intensive care unit stay were lower in the postintervention group. Multivariable analysis showed that the Delirium Team Approach program was associated with a reduction in postoperative delirium (odds ratio, 0.38; 95% confidence interval, 0.21-0.67; P = .001). Other predictors of delirium included age, dementia, chronic kidney disease, and intubation time. After risk adjustment using propensity score matching, the rate of postoperative delirium was lower in the postintervention group. CONCLUSIONS: Implementation of the Delirium Team Approach program was associated with a lower incidence of postoperative delirium in patients who underwent cardiovascular surgery.


Assuntos
Delírio do Despertar , Humanos , Estudos Retrospectivos , Escolaridade , Coração , Custos Hospitalares
8.
Perfusion ; 38(3): 530-538, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35105222

RESUMO

When employing minimal invasive extracorporeal circulation (MiECC), the removal of bubbles in the circuit is important to prevent air embolism. We investigated the bubble removal performance of the FHP oxygenator with a pre-filter and compared it with that of four oxygenators, including the Fusion oxygenator, Quadrox oxygenator, Inspire oxygenator, and FX oxygenator. A closed test circuit filled with an aqueous glycerin solution was used. Air injection (10 mL) was performed prior to the oxygenator, and the number and volume of the bubbles were measured at the inlet and outlet of each oxygenator. At the inlet of the five oxygenators, there were no significant differences in the total number of bubbles detected. At the outlet, bubbles were classified into two groups according to the bubble size: ≥100 µm and <100 µm. Tests were performed at pump flow rates of 4 and 5 L/min. For bubbles ≥100 µm, which are considered clinically detrimental, the FHP was the lowest number and volume of bubbles at both pump flow rates compared to the other oxygenators. Regarding the bubbles <100 µm, the number of bubbles was higher in the FHP than those in others; however, the volume of bubbles was significantly lower at 4 L/min and tended to be lower at 5 L/min. The use of the FHP with the pre-filter removed more bubbles ≥100 µm in the circuit than that by the other oxygenators.


Assuntos
Embolia Aérea , Oxigenadores de Membrana , Humanos , Desenho de Equipamento , Ponte Cardiopulmonar , Oxigenadores , Embolia Aérea/prevenção & controle
9.
Gen Thorac Cardiovasc Surg ; 71(4): 232-239, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35999411

RESUMO

OBJECTIVE: Preoperative assessment of frailty is important for predicting postoperative outcomes. This study investigated the association between frailty and late outcomes among patients who underwent thoracic aortic surgery via median sternotomy. METHODS: A total of 1010 patients underwent thoracic aortic surgery via median sternotomy between April 2008 and December 2016. Patients < 65 years of age, those who underwent urgent or emergent surgery, and those with incomplete data were excluded; as such, 374 patients were ultimately included in the present study. Frailty was evaluated using an index comprising history of dementia, body mass index < 18.5 kg/m2, and hypoalbuminemia. A frailty score from 0 to 3 was determined by assigning 1 point for each criterion met. Frailty was defined as a score ≥ 1. Patients were categorized into of 2 groups: frail (n = 52) and non-frail (n = 322). The mean follow-up was 6.1 ± 3.1 years. RESULTS: Overall in-hospital mortality did not differ between the frail and non-frail groups. However, the incidence of re-exploration for bleeding and discharge to a health care facility was higher in the frail group than in the non-frail group. Multivariable analysis revealed that preoperative frailty was an independent predictor of late mortality during follow-up [hazard ratio 3.71 (95% confidence interval 2.16-6.37); P < 0.001]. CONCLUSION: Preoperative frailty was associated with late mortality after thoracic aortic surgery. Assessment of preoperative frailty using a simple frailty index may be useful in the decision-making process for elderly patients.


Assuntos
Fragilidade , Humanos , Idoso , Fragilidade/complicações , Fragilidade/diagnóstico , Idoso Fragilizado , Fatores de Risco , Esternotomia/efeitos adversos , Resultado do Tratamento , Avaliação Geriátrica , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Medição de Risco
10.
J Card Surg ; 37(12): 5487-5489, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36168823

RESUMO

BACKGROUND: Reintervention for residual dissection after repaired type A aortic dissection remains challenging. When a frozen elephant trunk (FET) is used, the incidence of distal stent graft-induced new entry (d-SINE) is reportedly high in chronic dissection. AIMS: We report a case of successful redo arch repair using fenestrated and covered FET techniques for chronic residual aortic dissection. METHODS: After the arch was transected proximal to the left subclavian artery (LSCA), and a modified FET prosthesis, in which the distal edge of the FET was covered, was deployed. A fenestration was created in the FET on the LSCA aspect. RESULTS: The postoperative course was uneventful. DISCUSSION: The distal edge of the FET was covered to prevent d-SINE. Creation of a fenestration on the FET eliminates the need to reconstruct the LSCA. CONCLUSION: The fenestrated FET technique simplifies redo arch repair and the covered FET technique can potentially prevent d-SINE.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Stents , Resultado do Tratamento , Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Estudos Retrospectivos
11.
J Card Surg ; 37(10): 3101-3109, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35788988

RESUMO

BACKGROUND: We investigated the effects of frozen elephant trunk (FET) implantation on clinical outcomes in patients with acute type A aortic dissection (ATAAD) extending into the renal artery (RA). METHODS: Between May 2016 and April 2021, 136 patients underwent surgery for ATAAD at our hospital. Patients who died within 7 days postoperatively and those without preoperative contrast-enhanced computed tomography (CT) data were excluded from the study. The remaining 125 patients were included in this study. A preoperative CT-documented RA abnormality was found in 53 patients. Clinical outcomes, including renal dysfunction and CT findings, were compared between 29 patients with and 24 patients without the FET prosthesis. RESULTS: Among the 53 patients with RA abnormalities, origin of the RA from the false lumen was the most common type of abnormality. The percentage of men and rate of arch repair were higher, and the operation, cardiopulmonary bypass, and lower body hypothermic circulatory arrest times were longer in the FET than in the non-FET group. Early mortality rates were similar between groups. The incidence of postoperative acute kidney injury (AKI) was lower in the FET group (35% vs. 67%, p = 0.028). Multivariable analysis showed that FET implantation was associated with a low incidence of AKI (odds ratio: 0.28, 95% confidence interval: 0.08-0.96; p = 0.043). Among the 125 patients with or without RA abnormalities, no predictor of AKI was identified. CONCLUSION: FET implantation protected against postoperative AKI in patients with ATAAD extension into the RA.


Assuntos
Injúria Renal Aguda , Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/prevenção & controle , Dissecção Aórtica/etiologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Humanos , Masculino , Artéria Renal/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
12.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35678563

RESUMO

OBJECTIVES: The incidence rate of distal stent graft-induced new entry (d-SINE) after frozen elephant trunk technique for aortic dissection remains controversial. The aim of this study was to investigate the incidence and seek the clinical and anatomical predictive factors. METHODS: This study is a retrospective multicentre evaluation of complications including d-SINE, aortic events and reintervention after the frozen elephant trunk procedure for aortic dissection. RESULTS: Our cohort included a total of 177 consecutive patients who underwent the frozen elephant trunk procedure for acute and chronic aortic dissection at 5 centres in Japan from May 2014 to March 2021. The incidence rate of d-SINE was 14.1% (25/177 patients). The cumulative incidence of d-SINE was 7.1%, 12.4% and 21.4% after 12, 36 and 60 months, respectively. d-SINE was not associated with mid-term survival rate. After competing risk regression analysis, onset time >48 h (subdistribution hazard ratio, 3.80; 95% confidence interval, 1.13-12.79; P = 0.031) was detected as an independent predictor. CONCLUSIONS: Awareness that there is a relatively higher incidence of d-SINE after frozen elephant trunk procedures is important. Non-hyper-acute phase was detected as an independent risk factor. Pre-emptive endovascular repair may be appropriate to protect new entry in high-risk patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/efeitos adversos , Humanos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
13.
Ann Cardiothorac Surg ; 11(3): 268-272, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35733716

RESUMO

Left ventricular free wall rupture after acute myocardial infarction is uncommon but lethal and is still associated with high mortality rates. This paper presents the surgical treatment options and clinical management for post-infarction left ventricular free wall rupture. Various types of techniques, specifically sutureless repair using TachoComb/TachoSil, and intraoperative video images are discussed. Currently, sutureless repair is the most recommended treatment option when possible. However, appropriate selection of the surgical procedure remains important.

14.
J Card Surg ; 37(7): 2194-2196, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35438808

RESUMO

BACKGROUND: The left subclavian artery (LSCA) is deeply located and difficult to visualize in some cases of total arch replacement. AIMS: We report an end-to-side anastomosis technique that enables safer and easier anatomical reconstruction of the LSCA. MATERIALS AND METHODS: Under Hypothermic circulatory arrest, the origin of the LSCA was ligated and pulled caudally. With clamping the distal LSCA, a graft was anastomosed to the anterior wall of the LSCA and antegrade cerebral perfusion to the LSCA was ensured through the anastomosed graft. Thereafter, distal anastomosis was performed proximal to the LSCA. RESULTS: The postoperative course was uneventful. DISCUSSION: Our reconstruction technique provides excellent exposure of the LSCA by pulling the origin of the LSCA caudally. Hemostasis after reconstruction is feasible, as the anastomosis in the anterior wall of the LSCA is easily visualized. CONCLUSION: The end-to-side anastomosis technique for LSCA reconstruction is a simple alternative in arch repair.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Anastomose Cirúrgica , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Humanos , Artéria Subclávia/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-35170721

RESUMO

Distal stent graft-induced new entry is not rare after frozen elephant trunk implantation. We report a case of covered frozen elephant trunk placement for prevention of distal stent graft-induced new entry. Coverage of the rigid distal stent edge using a graft reduces mechanical stress on the intima and radial force of the distal stent; therefore, this technique can potentially prevent distal stent graft-induced new entry.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Humanos , Stents , Resultado do Tratamento
16.
J Artif Organs ; 25(2): 125-131, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34609623

RESUMO

Thoracic endovascular aortic repair is widely used for type B aortic dissection. However, there is no favorable stent-graft for type A aortic dissection. A significant limitation for device development is the lack of an experimental model for type A aortic dissection. We developed a novel three-dimensional biomodel of type A aortic dissection for endovascular interventions. Based on Digital Imaging and Communication in Medicine data from the computed tomography image of a patient with a type A aortic dissection, a three-dimensional biomodel with a true lumen, a false lumen, and an entry tear located at the ascending aorta was created using laser stereolithography and subsequent vacuum casting. The biomodel was connected to a pulsatile mock circuit. We conducted four tests: an endurance test for clinical hemodynamics, wire insertion into the biomodel, rapid pacing, and simulation of stent-graft placement. The biomodel successfully simulated clinical hemodynamics; the target blood pressure and cardiac output were achieved. The guidewire crossed both true and false lumens via the entry tear. The pressure and flow dropped upon rapid pacing and recovered after it was stopped. This simulation biomodel detected decreased false luminal flow by stent-graft placement and detected residual leak. The three-dimensional biomodel of type A aortic dissection with a pulsatile mock circuit achieved target clinical hemodynamics, demonstrated feasibility for future use during the simulated endovascular procedure, and evaluated changes in the hemodynamics.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Humanos , Stents , Resultado do Tratamento
17.
J Artif Organs ; 25(2): 132-139, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34665354

RESUMO

Negative impact of prosthesis-patient mismatch on long-term survival after valve replacement has been reported. However, the effect of prosthesis-patient mismatch after bioprosthetic mitral valve replacement has not yet been well examined. The purpose of this study was to investigate the effect of prosthesis-patient mismatch on late outcomes after bioprosthetic mitral valve replacement for mitral regurgitation. A total of 181 patients underwent bioprosthetic mitral valve replacement between April 2008 and December 2016. After excluding patients with mitral stenosis and those with incomplete data, 128 patients were included in the study. Postoperative transthoracic echocardiography was performed before discharge for all patients and the effective orifice area of bioprosthetic mitral valve was calculated using the formula: 220/pressure half-time, and the effective orifice area index was calculated by the formula: effective orifice area/body surface area. Prosthesis-patient mismatch was defined as a postoperative effective orifice area index ≤ 1.2 cm2/m2. The characteristics and outcomes were compared between the groups. There were 34 patients (26.6%) with prosthesis-patient mismatch and 94 patients (73.4%) without prosthesis-patient mismatch. There were no significant differences in the in-hospital mortality and morbidities. Multivariable analysis showed that prosthesis-patient mismatch was an independent predictor of late mortality (hazard ratio 3.38; 95% confidence interval 1.69-6.75; p = 0.001) and death from heart failure (hazard ratio 31.03, 95% confidence interval 4.49-214.40, p < 0.001). Prosthesis-patient mismatch at discharge after mitral valve replacement for mitral regurgitation was associated with long-term mortality and death from heart failure.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Aórtica/cirurgia , Insuficiência Cardíaca/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
18.
J Endovasc Ther ; 29(2): 289-293, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34362269

RESUMO

PURPOSE: We describe a pull-through pull-back technique to revascularize the left common carotid artery (LCCA) that was unintentionally covered during thoracic endovascular aortic repair (TEVAR). CASE REPORT: A 69-year-old man presented with back pain secondary to acute type B aortic dissection with an intimal tear in the proximal descending aorta. Serial computed tomography (CT) revealed an enlarged descending aorta and proximal progression of the aortic dissection. He underwent left carotid-subclavian artery bypass and TEVAR, 10 days after admission. The Valiant Navion stent graft without a bare stent was deployed proximally; however, the LCCA was unintentionally covered by the stent graft during this procedure. A pull-through form was created between the left axillary and femoral arteries using a 0.035-inch guide wire. The pull-through guide wire was gently pulled, and the greater curvature of the proximal end of the stent graft was displaced distally. Angiography confirmed restoration of antegrade blood flow into the LCCA. The patient's postoperative course was uneventful. Follow-up CT performed 6 months postoperatively confirmed preserved blood flow into the LCCA without endoleak nor stent migration. CONCLUSION: The pull-through pull-back technique is a feasible troubleshooting strategy for accidental coverage of supra-aortic vessels during TEVAR.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Masculino , Desenho de Prótese , Stents , Resultado do Tratamento
19.
Eur J Cardiothorac Surg ; 61(3): 625-634, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-34431991

RESUMO

OBJECTIVES: Transcatheter aortic valve replacement is known to be associated with improved haemodynamics in patients with aortic stenosis and a small aortic annulus. However, limited benchmark data are available regarding the long-term outcomes in patients treated with surgical aortic valve replacement (SAVR). We investigated the long-term outcomes of SAVR using a 19-mm bioprosthesis. METHODS: This study included consecutive patients who underwent SAVR using a 19-mm bioprosthesis at our hospital between 2008 and 2012. RESULTS: In a total of 132 patients, moderate and severe prosthesis-patient mismatch occurred in 36 (27.3%) and 7 patients (5.3%), respectively. The median follow-up period was 7.7 years. The overall 5- and 10-year survival rates were 79.4% and 52.9%, respectively. The 5- and 10-year freedom from major adverse valve-related events rates were 89.6% and 74.2%, respectively. Neither moderate nor severe prosthesis-patient mismatch was associated with late mortality, major adverse valve-related events or heart failure. Follow-up echocardiographic data were obtained at a median interval of 4.8 years in 80% of patients who survived ≥6 months postoperatively. Follow-up echocardiographic data showed a significantly increased left ventricular ejection fraction, decreased mean transvalvular/transprosthetic pressure gradients and a decreased mean left ventricular mass. At follow-up, we observed moderate or severe haemodynamic structural valve deterioration in 17 patients; however, structural valve deterioration did not affect late survival or freedom from major adverse valve-related events rates, or heart failure. CONCLUSIONS: SAVR using the 19-mm bioprosthesis was associated with satisfactory long-term clinical and haemodynamic outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...