PURPOSE: We aimed to develop a disposable rectum dosimeter and to demonstrate its ability to measure exposure dose to the rectum during brachytherapy for cervical cancer treatment using high-dose rate 192 Ir. Our rectum dosimeter measures the dose with an optically stimulated luminescence (OSL) sheet which was furled to a catheter. The catheter we used is 6 mm in diameter; therefore, it is much less invasive than other rectum dosimeters. The rectum dosimeter developed in this study has the characteristics of being inexpensive and disposable. It is also an easy-to-use detector that can be individually sterilized, making it suitable for clinical use. METHODS: To obtain a dose calibration curve, phantom experiments were performed. Irradiation was performed using a cubical acrylic phantom, and the response of the OSL dosimeter was calibrated with the calculation value predicted by the treatment planning system (TPS). Additionally, the dependence of catheter angle on the dosimeter position and repeatability were evaluated. We also measured the absorbed dose to the rectum of patients who were undergoing brachytherapy for cervical cancer (n = 64). The doses measured with our dosimeters were compared with the doses calculated by the TPS. In order to examine the causes of large differences between measured and planned doses, we classified the data into common and specific cases when performing this clinical study. For specific cases, the following three categories were considered: (a) patient movement, (b) gas in the vagina and/or rectum, and (c) artifacts in the X-ray image caused by applicators. RESULTS: A dose calibration curve was obtained in the range of 0.1 Gy-10.0 Gy. From the evaluation of the dependence of catheter angle on the dosimeter position and repeatability, we determined that our dosimeter can measure rectum dose with an accuracy of 3.1% (k = 1). In this clinical study, we succeeded in measuring actual doses using our rectum dosimeter. We found that the deviation of the measured dose from the planned dose was derived to be 12.7% (k = 1); this result shows that the clinical study included large elements of uncertainty. The discrepancies were found to be due to patient motion during treatment, applicator movement after planning images were taken, and artifacts in the planning images. CONCLUSIONS: We present the idea that a minimally invasive rectum dosimeter can be fabricated using an OSL sheet. Our clinical study demonstrates that a rectum dosimeter made from an OSL sheet has sufficient ability to evaluate rectum dose. Using this dosimeter, valuable information concerning organs at risk can be obtained during brachytherapy.


Assuntos
Braquiterapia , Dosímetros de Radiação , Feminino , Humanos , Luminescência , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Reto
2.
Radiol Phys Technol ; 10(1): 49-59, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27341805

RESUMO

Entrance surface dose (ESD) measurements are important in X-ray computed tomography (CT) for examination, but in clinical settings it is difficult to measure ESDs because of a lack of suitable dosimeters. We focus on the capability of a small optically stimulated luminescence (OSL) dosimeter. The aim of this study is to propose a practical method for using an OSL dosimeter to measure the ESD when performing a CT examination. The small OSL dosimeter has an outer width of 10 mm; it is assumed that a partial dose may be measured because the slice thickness and helical pitch can be set to various values. To verify our method, we used a CT scanner having 320 rows of detectors and checked the consistencies of the ESDs measured using OSL dosimeters by comparing them with those measured using Gafchromic™ films. The films were calibrated using an ionization chamber on the basis of half-value layer estimation. On the other hand, the OSL dosimeter was appropriately calibrated using a practical calibration curve previously proposed by our group. The ESDs measured using the OSL dosimeters were in good agreement with the reference ESDs from the Gafchromic™ films. Using these data, we also estimated the uncertainty of ESDs measured with small OSL dosimeters. We concluded that a small OSL dosimeter can be considered suitable for measuring the ESD with an uncertainty of 30 % during CT examinations in which pitch factors below 1.000 are applied.


Assuntos
Doses de Radiação , Dosímetros de Radiação , Tomógrafos Computadorizados , Humanos , Imagens de Fantasmas , Água
3.
Radiol Phys Technol ; 9(2): 286-92, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27260346

RESUMO

Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1-20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40-120 kVp and 0.5-1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.


Assuntos
Luminescência , Radiografia/instrumentação , Radiometria/instrumentação , Absorciometria de Fóton , Limite de Detecção , Imagens de Fantasmas
4.
Radiol Phys Technol ; 9(1): 99-108, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26589210

RESUMO

For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.


Assuntos
Luminescência , Dispositivos Ópticos , Radiometria/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Método de Monte Carlo , Raios X
5.
Radiol Phys Technol ; 8(2): 286-94, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25975450

RESUMO

For X-ray diagnosis, the proper management of the entrance skin dose (ESD) is important. Recently, a small-type optically stimulated luminescence dosimeter (nanoDot OSL dosimeter) was made commercially available by Landauer, and it is hoped that it will be used for ESD measurements in clinical settings. Our objectives in the present study were to propose a method for calibrating the ESD measured with the nanoDot OSL dosimeter and to evaluate its accuracy. The reference ESD is assumed to be based on an air kerma with consideration of a well-known back scatter factor. We examined the characteristics of the nanoDot OSL dosimeter using two experimental conditions: a free air irradiation to derive the air kerma, and a phantom experiment to determine the ESD. For evaluation of the ability to measure the ESD, a calibration curve for the nanoDot OSL dosimeter was determined in which the air kerma and/or the ESD measured with an ionization chamber were used as references. As a result, we found that the calibration curve for the air kerma was determined with an accuracy of 5 %. Furthermore, the calibration curve was applied to the ESD estimation. The accuracy of the ESD obtained was estimated to be 15 %. The origin of these uncertainties was examined based on published papers and Monte-Carlo simulation. Most of the uncertainties were caused by the systematic uncertainty of the reading system and the differences in efficiency corresponding to different X-ray energies.


Assuntos
Luminescência , Radiometria/instrumentação , Pele/diagnóstico por imagem , Calibragem , Humanos , Método de Monte Carlo , Radiografia , Reprodutibilidade dos Testes , Incerteza
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(10): 1135-42, 2014 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-25327423

RESUMO

The optically stimulated luminescence (OSL) dosimeter is a useful detector for measuring absorbed doses of X-rays. A small-type OSL dosimeter, "nanoDot", has recently been developed by Landauer, Inc., who also manufacture "microStar" reading equipment. However, additional annealing equipment is needed if the nanoDot OSL dosimeter is used repeatedly. The aim of this study was to fabricate suitable annealing equipment using commonly available products. Our device positions four fluorescent light tubes in a close configuration. The heat from the fluorescent light tubes is dissipated using fans. Experiments using diagnostic X-ray equipment were carried out to evaluate the capability of our annealing equipment. The results indicated that our equipment can fully anneal the nanoDot OSL dosimeter with annealing times of approximately 20 hours.


Assuntos
Dosimetria Termoluminescente/instrumentação , Desenho de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Dosimetria Termoluminescente/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...