Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foods ; 10(11)2021 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-34829029

RESUMO

Insects are part of the diet of over 2 billion people worldwide; however, insects have not been popular in Europe, neither as food nor as a feed ingredient. This has been changing in recent years, due to increased knowledge regarding the nutritional benefits, the need for novel protein production and the low environmental impact of insects compared to conventional protein production. The purpose of this study is to give an overview of the most popular insects farmed in Europe, yellow mealworm, Tenebrio molitor, and black soldier fly (BSF), Hermetia illucens, together with the main obstacles and risks. A comprehensive literature study was carried out and 27 insect farming companies found listed in Europe were contacted directly. The results show that the insect farming industry is increasing in Europe, and the success of the frontrunners is based on large investments in technology, automation and economy of scale. The interest of venture capital firms is noticeable, covering 90% of the investment costs in some cases. It is concluded that insect farming in Europe is likely to expand rapidly in the coming years, offering new proteins and other valuable products, not only as a feed ingredient, but also for human consumption. European regulations have additionally been rapidly changing, with more freedom towards insects as food and feed. There is an increased knowledge regarding safety concerns of edible insects, and the results indicate that edible insects pose a smaller risk for zoonotic diseases than livestock. However, knowledge regarding risk posed by edible insects is still lacking, but food and feed safety is essential to put products on the European market.

2.
J Appl Clin Med Phys ; 19(3): 291-300, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29508535

RESUMO

This paper describes Development of a Phantom for Tomosynthesis with Potential for Automated Analysis via the Cloud. Several studies are underway to investigate the effectiveness of Tomosynthesis Mammographic Image Screening, including the large TMIST project as funded by the National Cancer Institute https://www.cancer.gov/about-cancer/treatment/clinical-trials/nci-supported/tmist. The development of the phantom described in this paper follows initiatives from the FDA, the AAPM TG245 task group, and European Reference Organization (EUREF) for Quality Assured Breast Screening and Diagnostic Services Committee report noting, that no formal endorsement nor recommendation for use has been sought, or granted by any of these groups. This paper reports on the possibility of using this newly developed Tomosynthesis Phantom for Quality Assurance, field testing of image performance, including remote monitoring of DBT system performance, e.g., via transmission over the cloud. The phantom includes tests for: phantom positioning and alignment (important for remote analysis), scan geometry (x and y), chest wall offset, scan slice width and Slice Sensitivity Profile (SSP(z)) slice geometry (slice width), scan slice incrementation (z), z axis geometry bead, low contrast detectability using low contrast spheres, spatial resolution via Point Spread Function (PSF), Image uniformity, Signal to Noise Ratio (SNR), and Contrast to Noise Ratio (CNR) via readings over an Aluminum square. The phantom is designed for use with automated analysis via transmission of images over the cloud and the analysis package includes test of positioning accuracy (roll, pitch, and yaw). Data are shown from several commercial Tomosynthesis Scanners including Fuji, GE, Hologic, IMS-Giotti, and Siemens; however, the focus of this paper is on phantom design, and not in general aimed at direct commercial comparisons, and wherever possible the identity of the data is anonymized. Results of automated analysis of the phantom are shown, and it is demonstrated that reliable analysis of such a phantom can be achieved remotely, including transmission of data through the cloud.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Desenho de Equipamento , Processamento de Imagem Assistida por Computador/normas , Mamografia/instrumentação , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Razão Sinal-Ruído
3.
J Appl Clin Med Phys ; 17(5): 440-452, 2016 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-27685130

RESUMO

Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) influence the visual-ization and detection of objects within the scanned volume. This study investigates ways to consider both the in-plane resolution and the z-axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the "Wave Phantom" is developed that can be used to sample the 3D resolution properties of a CT image, including in-plane (x,y) and z-axis information. The key development in this Wave Phantom is the incorporation of a z-axis aspect of a more traditional step (bar) resolution gauge phantom. The phantom can be examined visually wherein a cutoff level may be seen; and/or the analytic analysis of the various characteristics of the waveform profile by including amplitude, frequency, and slope (rate of climb) of the peaks, can be extracted from the Wave Pattern using mathematical analysis such as the Fourier transform. The combined effect of changes in in-plane resolution and z-axis (thickness), are shown, as well as the effect of changes in either in-plane resolu-tion, or z-axis thickness. Examples of visual images of the Wave pattern as well as the analytic characteristics of the various harmonics of a periodic Wave pattern resulting from changes in resolution filter and/or slice thickness, and position in the field of view are shown. The Wave Phantom offers a promising way to investigate 3D resolution results from combined effect of in-plane (x-y) and z-axis resolution as contrasted to the use of simple 2D resolution gauges that need to be used with separate measures of z-axis dependency, such as angled ramps. It offers both a visual pattern as well as a pattern amenable to analytic analysis using Fourier Transform methods, and is believed to offer an image quality test closer to the diagnostic task where the 2D image has the hidden third (z) axis effects.


Assuntos
Imageamento Tridimensional/métodos , Imagens de Fantasmas , Tomógrafos Computadorizados/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos
4.
Artigo em Inglês | MEDLINE | ID: mdl-18044600

RESUMO

This paper introduces a novel approach to quantify asymmetry in each point of a surface. The measure is based on analysing displacement vectors resulting from nonrigid image registration. A symmetric atlas, generated from control subjects is registered to a given subject image. A comparison of the resulting displacement vectors on the left and right side of the symmetry plane, gives a point-wise measure of asymmetry. The asymmetry measure was applied to the study of Crouzon syndrome using Micro CT scans of genetically modified mice. Crouzon syndrome is characterised by the premature fusion of cranial sutures, which gives rise to a highly asymmetric growth. Quantification and localisation of this asymmetry is of high value with respect to surgery planning and treatment evaluation. Using the proposed method, asymmetry was calculated in each point of the surface of Crouzon mice and wild-type mice (controls). Asymmetry appeared in similar regions for the two groups but the Crouzon mice were found significantly more asymmetric. The localisation ability of the method was in good agreement with ratings from a clinical expert. Validating the quantification ability is a less trivial task due to the lack of a gold standard. Nevertheless, a comparison with a different, but less accurate measure of asymmetry revealed good correlation.


Assuntos
Inteligência Artificial , Disostose Craniofacial/diagnóstico por imagem , Modelos Animais de Doenças , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Corporal Total/métodos , Algoritmos , Animais , Camundongos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Anat ; 211(1): 37-52, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17553099

RESUMO

Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landmarks from two different observers and automatically assessed landmarks. Both of the automatic approaches were within the interobserver accuracy for normal specimens, and the non-rigid approach was within the interobserver accuracy for the Crouzon specimens. Four linear measurements, skull length, height and width and interorbital distance, were carried out automatically using the two different approaches. Both automatic approaches assessed the skull length, width and height accurately for both groups of mice. The non-rigid approach measured the interorbital distance accurately for both groups while the affine approach failed to assess this parameter for both groups. Using the full capability of the non-rigid approach, local displacements obtained when registering the non-rigid wild-type atlas to a non-rigid Crouzon mouse atlas were determined on the surface of the wild-type atlas. This revealed a 0.6-mm bending in the nasal region and a 0.8-mm shortening of the zygoma, which are similar to characteristics previously reported in humans. The most striking finding of this analysis was an angulation of approximately 0.6 mm of the cranial base, which has not been reported in humans. Comparing the two different methodologies, it is concluded that the non-rigid approach is the best way to assess linear skull parameters automatically. Furthermore, the non-rigid approach is essential when it comes to analysing local, non-linear shape differences.


Assuntos
Disostose Craniofacial/diagnóstico por imagem , Modelos Animais , Mutação , Reconhecimento Automatizado de Padrão , Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Animais , Disostose Craniofacial/patologia , Bases de Dados como Assunto , Ossos Faciais/diagnóstico por imagem , Ossos Faciais/patologia , Humanos , Camundongos , Camundongos Mutantes , Receptor Tipo 2 de Fator de Crescimento de Fibroblastos , Padrões de Referência , Crânio/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...