Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
N Engl J Med ; 383(18): 1724-1734, 2020 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-32871063

RESUMO

BACKGROUND: Little is known about the nature and durability of the humoral immune response to infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). METHODS: We measured antibodies in serum samples from 30,576 persons in Iceland, using six assays (including two pan-immunoglobulin [pan-Ig] assays), and we determined that the appropriate measure of seropositivity was a positive result with both pan-Ig assays. We tested 2102 samples collected from 1237 persons up to 4 months after diagnosis by a quantitative polymerase-chain-reaction (qPCR) assay. We measured antibodies in 4222 quarantined persons who had been exposed to SARS-CoV-2 and in 23,452 persons not known to have been exposed. RESULTS: Of the 1797 persons who had recovered from SARS-CoV-2 infection, 1107 of the 1215 who were tested (91.1%) were seropositive; antiviral antibody titers assayed by two pan-Ig assays increased during 2 months after diagnosis by qPCR and remained on a plateau for the remainder of the study. Of quarantined persons, 2.3% were seropositive; of those with unknown exposure, 0.3% were positive. We estimate that 0.9% of Icelanders were infected with SARS-CoV-2 and that the infection was fatal in 0.3%. We also estimate that 56% of all SARS-CoV-2 infections in Iceland had been diagnosed with qPCR, 14% had occurred in quarantined persons who had not been tested with qPCR (or who had not received a positive result, if tested), and 30% had occurred in persons outside quarantine and not tested with qPCR. CONCLUSIONS: Our results indicate that antiviral antibodies against SARS-CoV-2 did not decline within 4 months after diagnosis. We estimate that the risk of death from infection was 0.3% and that 44% of persons infected with SARS-CoV-2 in Iceland were not diagnosed by qPCR.


Assuntos
Infecções por Coronavirus/imunologia , Imunidade Humoral , Pneumonia Viral/imunologia , Estudos Soroepidemiológicos , Adulto , Idoso , Anticorpos Antivirais/sangue , Betacoronavirus , COVID-19 , Infecções por Coronavirus/mortalidade , Feminino , Humanos , Islândia/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/mortalidade , Reação em Cadeia da Polimerase , Quarentena , SARS-CoV-2
2.
Am J Infect Control ; 46(6): 697-705, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29395506

RESUMO

BACKGROUND: Bacterial culture is the accepted standard to measure the adequacy of high-level disinfection (HLD) of duodenoscopes. Adenosine triphosphate (ATP) bioluminescence assays have been suggested as an alternative method of evaluating the quality of reprocessing. We systematically reviewed published research describing the correlation between ATP and bacterial cultures. METHODS: The primary outcome was the correlation or concordance between concomitantly sampled ATP and bacterial contamination obtained from the instrument channel and/or elevator mechanism of the duodenoscope. A secondary outcome included the reduction in ATP measurements between paired samples before and after stages of duodenoscope reprocessing. RESULTS: Ten studies were included in the analysis. Four studies reported the relationship between concomitantly sampled ATP and cultures. Three studies reported receiver operating characteristic curves (1 study additionally reported a Wilcoxon rank sum test), and 1 study reported Spearman correlation coefficients and paired dichotomous measurements of ATP and bacterial contamination. All analyses suggested a poor relationship between the 2 measures. Studies measuring ATP before and after manual cleaning and before and after HLD reported a reduction in ATP after the reprocessing stage. CONCLUSION: Current research does not support the direct substitution of ATP for bacterial culture surveillance of duodenoscopes. Serial ATP measurement may be a useful tool to evaluate the adequacy of manual cleaning and for training of endoscopic reprocessing staff.


Assuntos
Trifosfato de Adenosina/análise , Bactérias/isolamento & purificação , Colangiopancreatografia Retrógrada Endoscópica/métodos , Duodenoscópios/microbiologia , Contaminação de Equipamentos , Técnicas Bacteriológicas , Medições Luminescentes
3.
Gastroenterology ; 153(4): 1018-1025, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28711629

RESUMO

BACKGROUND AND AIMS: Duodenoscopes have been implicated in the transmission of multidrug-resistant organisms (MDRO). We compared the frequency of duodenoscope contamination with MDRO or any other bacteria after disinfection or sterilization by 3 different methods. METHODS: We performed a single-center prospective randomized study in which duodenoscopes were randomly reprocessed by standard high-level disinfection (sHLD), double high-level disinfection (dHLD), or standard high-level disinfection followed by ethylene oxide gas sterilization (HLD/ETO). Samples were collected from the elevator mechanism and working channel of each duodenoscope and cultured before use. The primary outcome was the proportion of duodenoscopes with an elevator mechanism or working channel culture showing 1 or more MDRO; secondary outcomes included the frequency of duodenoscope contamination with more than 0 and 10 or more colony-forming units (CFU) of aerobic bacterial growth on either sampling location. RESULTS: After 3 months of enrollment, the study was closed because of the futility; we did not observe sufficient events to evaluate the primary outcome. Among 541 duodenoscope culture events, 516 were included in the final analysis. No duodenoscope culture in any group was positive for MDRO. Bacterial growth of more than 0 CFU was noted in 16.1% duodenoscopes in the sHLD group, 16.0% in the dHLD group, and 22.5% in the HLD/ETO group (P = .21). Bacterial growth or 10 or more CFU was noted in 2.3% of duodenoscopes in the sHLD group, 4.1% in the dHLD group, and 4.2% in the HLD/ETO group (P = .36). MRDOs were cultured from 3.2% of pre-procedure rectal swabs and 2.5% of duodenal aspirates. CONCLUSIONS: In a comparison of duodenoscopes reprocessed by sHLD, dHLD, or HLD/ETO, we found no significant differences between groups for MDRO or bacteria contamination. Enhanced disinfection methods (dHLD or HLD/ETO) did not provide additional protection against contamination. However, insufficient events occurred to assess our primary study end-point. ClinicalTrials.gov no: NCT02611648.


Assuntos
Infecção Hospitalar/prevenção & controle , Desinfetantes , Desinfecção/métodos , Farmacorresistência Bacteriana Múltipla , Duodenoscópios/microbiologia , Duodenoscopia/instrumentação , Contaminação de Equipamentos/prevenção & controle , Reutilização de Equipamento , Óxido de Etileno , Esterilização/métodos , o-Ftalaldeído , Técnicas Bacteriológicas , Infecção Hospitalar/microbiologia , Infecção Hospitalar/transmissão , Duodenoscópios/efeitos adversos , Duodenoscopia/efeitos adversos , Gases , Humanos , Estudos Prospectivos , Fatores de Tempo
4.
Infect Control Hosp Epidemiol ; 38(6): 678-684, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28414009

RESUMO

OBJECTIVE The aim of this study was to quantify the correlation between adenosine triphosphate (ATP) measurements and bacterial cultures from duodenoscopes for evaluation of contamination following high-level disinfection. DESIGN Duodenoscopes used for any intended endoscopic retrograde cholangiopancreatography (ERCP) procedure were included. Microbiologic and ATP data were collected concomitantly and in the same manner from ERCP duodenoscopes. SETTING A high-volume endoscopy unit at a tertiary referral acute-care facility. METHODS Duodenoscopes were sampled for ATP and bacterial contamination in a contemporaneous and highly standardized fashion using a "flush-brush-flush" method for the working channel (WC) and a dry flocked swab for the elevator mechanism (EM). Specimens were processed for any aerobic bacterial growth (colony-forming units, CFU). Growth of CFU>0 and ATP relative light unit (RLU)>0 was considered a contaminated result. Frequency of discord between among WC and EM measurements were calculated using 2×2 contingency tables. The Spearman correlation coefficient was used to calculate the relatedness of bacterial contamination and ATP as continuous measurements. RESULTS The Spearman correlation coefficient did not demonstrate significant relatedness between ATP and CFU for either a WC or EM site. Among 390 duodenoscope sampling events, ATP and CFU assessments of contamination were discordant in 82 of 390 WC measurements (21%) and 331 of 390 of EM measurements (84.9%). The EM was frequently and markedly positive by ATP measurement. CONCLUSION ATP measurements correlate poorly with a microbiologic standard assessing duodenoscope contamination, particularly for EM sampling. ATP may reflect biological material other than nonviable aerobic bacteria and may not serve as an adequate marker of bacterial contamination. Infect Control Hosp Epidemiol 2017;38:678-684.


Assuntos
Trifosfato de Adenosina/análise , Bactérias/crescimento & desenvolvimento , Duodenoscópios/microbiologia , Contaminação de Equipamentos , Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Contagem de Colônia Microbiana , Desinfecção , Reutilização de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...