1.
Onco Targets Ther ; 10: 4099-4103, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28860818

RESUMO

INTRODUCTION: Resection of manubrium or body of the sternum is associated with a necessity of chest wall reconstruction. Large sternal defects require the use of different types of implants to ensure acceptable esthetic effect for the patient and chest stabilization. AIM: The purpose of this case report is to present a novel method of reconstruction of manubrium removed due to renal cancer metastasis to the sternum. CASE: We present the case of a patient, who had underwent right nephrectomy for clear cell kidney cancer, diagnosed with a metastatic tumor in the sternum resulting in destruction of manubrium. The patient undergone tumor resection with primary reconstruction with an individual prosthesis. Sternal defect was filled with a personalized, computed tomography scan-based 3D-milled implant made of polyethylene. RESULTS: Sternal reconstruction was uneventful. The patient endured surgery well, and has been under surveillance in outpatient clinic, without any respiration disorders, implant movement or local recurrence. CONCLUSION: Custom-designed sternal implants created by 3D technique constitute an interesting alternative for previous methods of filling defects after resection of a tumor in this location.

2.
Clin Oral Investig ; 21(5): 1853-1859, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27766488

RESUMO

OBJECTIVE: This study aimed to present a new possibility to create radio-opaque implant material for craniomaxillofacial reconstruction. MATERIALS AND METHODS: The test disks made of the own compound of polyethylenes with addiction of 2, 4, and 6 % of weight TiO2 was investigated for cytotoxicity [each group 15 disks respectively]. Next, computed tomography of the disks was performed in environment of muscle and fat. Hardness, tensile modulus and strength, and compressive modulus and strength were tested too. RESULTS: Deterioration of mechanical properties of the composites containing titanium dioxide was observed [hardness, tensile modulus and strength, compressive modulus and strength, respectively: 56.7 ± 1.6 shore D, 354 ± 52, 22.5 ± 1.3, 21.8 ± 1.1, and 2995 ± 327 MPa as addiction of 2 % TiO2; 52.0 ± 0.9 shore D, 347 ± 66, 18.0 ± 0.7, 14.2 ± 0.9, and 1396 ± 477 MPa as 4 % TiO2; 51.3 ± 1.3 shore D, 316 ± 9, 17.4 ± 0.2, 13.6 ± 0.6, and 1100 ± 144 MPa as 6 % TiO2 added]. The test disks revealed no cytotoxicity effect on human osteoblasts. The new material presents mild radio-opacity which was enough to observe the implant in relation to fat and muscle, but with no visible effect of beam hardening. CONCLUSION: In view of the performed tests, the polyethylene enriched by titanium dioxide seems to be a proper material to consider manufacturing of craniomaxillofacial implants. CLINICAL RELEVANCE: Maxilloafacial surgery is still looking for new implantologic materials. The proposed one is a new way to manufacture an implant visible in computed tomography which does not interfere with its shape in radiological examination and makes it possible to observe the surrounding soft tissues.


Assuntos
Resinas Acrílicas/química , Prótese Maxilofacial , Polietileno/química , Desenho de Prótese , Materiais Dentários/química , Módulo de Elasticidade , Dureza , Humanos , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Titânio/química , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...