Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 19(1): 250-258, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29193644

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation. METHODS: Hand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick-check method (QC) and occasional side-handle (SH) manipulation of the needle. The second series (63 biopsies) were performed after introducing needle holders (NH) in the course of an optimization process. RESULTS: Choice of technique (QC, QC + NH, QC + SH) by the interventional radiologist (IR) was related to biopsy difficulty. Measured hand exposure was low (< 1 mSv) for all QC-only procedures, and for most of the QC + NH procedures. Occasional side-handle manipulation still occurred during challenging biopsies, so that 8% of biopsies in the second series accounted for ~70% of total fingertip dose (~90 mSv). The methodology used allowed a detailed insight into the dose reduction achievable with needle holders during real procedures, without the limitations of phantom measurements. CONCLUSIONS: Needle holders proved effective in reducing mean hand exposure during clinical procedures where real-time manipulation was necessary. Occasional side-handle manipulation was found to contribute disproportionately to hand exposure. This highlights the importance of individual hand monitoring during CTF guided procedures.


Assuntos
Fluoroscopia/instrumentação , Mãos/efeitos da radiação , Exposição Ocupacional/análise , Imagens de Fantasmas , Proteção Radiológica/métodos , Radiografia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Biópsia por Agulha , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
2.
J Appl Clin Med Phys ; 17(1): 316-327, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894341

RESUMO

Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the base of one finger, while the fingertips may be exposed to the highly collimated CT beam. In this work we have explored the possibility of using Gafchromic XR-QA2 self-developing film as a complementary dosimeter to quantify hand exposure during CTF-guided biopsies. A glove used in a previous study and designed to contain 11 TLDs was adapted to include Gafchromic strips 7 mm wide, covering the fingers. A total of 22 biopsies were successfully performed wearing this GafTLD glove under sterile gloves, and the IR reported no difficulty or reduction of dexterity while wearing it. Comparison of dose distributions obtained from digitization of the Gafchromic film strips and absolute Hp(0.07) readings from TLDs showed good agreement, despite some positional uncertainty due to relative movement. Per procedure, doses at the base of the ring finger can be as low as 3%-8% of hand dose maximum. Accumulated dose at the base of the ring finger was four times lower than the dose maximum.


Assuntos
Dosimetria Fotográfica/métodos , Fluoroscopia/métodos , Mãos/efeitos da radiação , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Biópsia , Calibragem , Dosimetria Fotográfica/instrumentação , Mãos/diagnóstico por imagem , Humanos , Doses de Radiação , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...