Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Cardiovasc Magn Reson ; 26(1): 101041, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527706

RESUMO

Cardiovascular magnetic resonance (CMR) has become the reference standard for quantitative and qualitative assessment of ventricular function, blood flow, and myocardial tissue characterization. There is a preponderance of large CMR studies and registries in adults; However, similarly powered studies are lacking for the pediatric and congenital heart disease (PCHD) population. To date, most CMR studies in children are limited to small single or multicenter studies, thereby limiting the conclusions that can be drawn. Within the PCHD CMR community, a collaborative effort has been successfully employed to recognize knowledge gaps with the aim to embolden the development and initiation of high-quality, large-scale multicenter research. In this publication, we highlight the underlying challenges and provide a practical guide toward the development of larger, multicenter initiatives focusing on PCHD populations, which can serve as a model for future multicenter efforts.


Assuntos
Cardiopatias Congênitas , Estudos Multicêntricos como Assunto , Valor Preditivo dos Testes , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Criança , Big Data , Imageamento por Ressonância Magnética , Projetos de Pesquisa , Fatores Etários , Adolescente , Pré-Escolar
2.
J Am Coll Cardiol ; 83(1): 63-81, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171712

RESUMO

Recent years have witnessed exponential growth in cardiac imaging technologies, allowing better visualization of complex cardiac anatomy and improved assessment of physiology. These advances have become increasingly important as more complex surgical and catheter-based procedures are evolving to address the needs of a growing congenital heart disease population. This state-of-the-art review presents advances in echocardiography, cardiac magnetic resonance, cardiac computed tomography, invasive angiography, 3-dimensional modeling, and digital twin technology. The paper also highlights the integration of artificial intelligence with imaging technology. While some techniques are in their infancy and need further refinement, others have found their way into clinical workflow at well-resourced centers. Studies to evaluate the clinical value and cost-effectiveness of these techniques are needed. For techniques that enhance the value of care for congenital heart disease patients, resources will need to be allocated for education and training to promote widespread implementation.


Assuntos
Inteligência Artificial , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia , Técnicas de Imagem Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos
3.
Eur Heart J Open ; 4(1): oead138, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38223303

RESUMO

Aims: Coarctation of the aorta is associated with long-term morbidity including decreased exercise capacity, despite successful repair. In the absence of discrete recoarctation, the haemodynamic mechanism remains unknown. This multicentre study evaluated the relationship between aorta shape, flow, and exercise capacity in patients after arch repair, specifically through the lens of aortic size mismatch and descending aortic (DAo) flow and their association with exercise. Methods and results: Cardiac magnetic resonance, cardiopulmonary exercise test, and echocardiogram data within 1 year were analysed from 58 patients (age 28 ± 10 years, 48% male) across four centres with history of isolated arch repair. Aortic arch measurements were correlated with % predicted VO2max with subgroup analyses of those with residual arch obstruction, bicuspid aortic valve, and hypertension. Ascending aorta (AAo) to DAo diameter ratio (DAAo/DDAo) was negatively correlated with % predicted VO2max. %DAo flow positively correlated with VO2max. Sub-analyses demonstrated that the negative correlation of DAAo/DDAo with VO2max was maintained only in patients without arch obstruction and with a bicuspid aortic valve. Smaller aortic arch measurements were associated with both hypertension and exercise-induced hypertension. Conclusion: Aorta size mismatch, due to AAo dilation or small DAo, and associated decreased %DAo flow, correlated significantly with decreased exercise capacity after aortic arch repair. These correlations were stronger in patients without arch obstruction and with a bicuspid aortic valve. Aorta size mismatch and %DAo flow capture multiple mechanisms of altered haemodynamics beyond blood pressure gradient or discrete obstruction and can inform the definition of a successful repair.

4.
J Clin Med ; 12(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37048773

RESUMO

BACKGROUND: Sarcopenia is an increasingly recognized marker of frailty in cardiac patients. Patients with a history of congenital heart disease and Fontan procedure have a higher risk of developing progressive muscle wasting. Our objective was to determine if we could use routine cardiac MRI (CMR) for the surveillance of muscle wasting. METHODS: A retrospective study of all Fontan patients (n = 75) was conducted at our institution, with CMR performed from 2010 to 2022 and exercise stress testing performed within 12 months (4.3 ± 4.2 months). The skeletal muscle area (SMA) for the posterior paraspinal and anterior thoracic muscles were traced and indexed for body surface area (BSA). Patients were stratified by percentile into the upper and lower quartiles, and the two groups were compared. Multivariable regression was performed to control for sex and age. RESULTS: There was a significant positive association of both anterior (r = 0.34, p = 0.039) and paraspinal (r = 0.43, p = 0.007) SMA to peak VO2. Similarly, paraspinal but not anterior SMA was negatively associated with the VE/VCO2 (r = -0.45, p = 0.006). The upper quartile group had significantly more males (18/19 vs. 8/20; p = 0.0003) and demonstrated a significantly higher peak VO2 (32.2 ± 8.5 vs. 23.8 ± 4.7, p = 0.009), a higher peak RER (1.2 ± 0.1 vs. 1.1 ± 0.04, p = 0.007), and a significantly lower VE/VCO2 (32.9 ± 3.6 vs. 40.2 ± 6.2, p = 0.006) compared to the lowest quartile. The association of SMA to VO2 peak and VE/VCO2 was redemonstrated after controlling for sex and age. CONCLUSION: Thoracic skeletal muscle area may be an effective surrogate of muscle mass and is correlated to several measures of cardiorespiratory fitness post-Fontan. CMR would be an effective tool for the surveillance of sarcopenia in post-Fontan patients given its accessibility and routine use in these patients.

5.
Pediatr Cardiol ; 44(1): 15-23, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36151322

RESUMO

Ebstein anomaly is the most common form of tricuspid valve congenital anomalies. The tricuspid valve is abnormal with different degrees of displacement of the septal leaflet and abnormal rotation of the valve towards the right ventricular outflow tract. In severe forms, it results in significant tricuspid regurgitation and requires surgical repair. There is an increased interest in understanding the anatomy of the tricuspid valve in this lesion as the surgical repair has evolved with the invention and wide adoption of the cone operation. Multimodality imaging plays an important role in diagnosis, follow-up, surgical planning and post-operative care. This review provides anatomical tips for the cardiac imagers caring for patients with Ebstein anomaly and will help provide image-based personalized medicine.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Anomalia de Ebstein , Insuficiência da Valva Tricúspide , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos
6.
J Am Coll Cardiol ; 80(23): 2239-2250, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36456054

RESUMO

The National Heart, Lung, and Blood Institute convened a workshop in August 2021 to identify opportunities in pediatric and congenital cardiovascular research that would improve outcomes for individuals with congenital heart disease across the lifespan. A subsidiary goal was to provide feedback on and visions for the Pediatric Heart Network. This paper summarizes several key research opportunities identified in the areas of: data quality, access, and sharing; aligning cardiovascular research with patient priorities (eg, neurodevelopmental and psychological impacts); integrating research within clinical care and supporting implementation into practice; leveraging creative study designs; and proactively enriching diversity of investigators, participants, and perspectives throughout the research process.


Assuntos
Doenças Cardiovasculares , Humanos , Criança , Doenças Cardiovasculares/terapia , Coração , Longevidade , Confiabilidade dos Dados , Projetos de Pesquisa
7.
J Cardiovasc Magn Reson ; 24(1): 58, 2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36352454

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of contrast agent (ferumoxytol vs. gadolinium) may influence 4D Flow CMR accuracy. Thus, we investigated the accuracy of 4D Flow CMR measurements compared to gold standard 2D flow phase contrast (PC) measurements in ferumoxytol vs. gadolinium-enhanced CMR of small CHD patients with shunt lesions. METHODS: This was a retrospective study consisting of CMR studies from complex CHD patients less than 20 kg who had ferumoxytol or gadolinium-enhanced 4D Flow and standard two-dimensional phase contrast (2D-PC) flow collected. 4D Flow clinical software (Arterys) was used to measure flow in great vessels, systemic veins, and pulmonary veins. 4D Flow accuracy was defined as percent difference or correlation against conventional measurements (2D-PC) from the same vessels. Subgroup analysis was performed on two-ventricular vs single-ventricular CHD, arterial vs venous flow, as well as low flows (defined as < 1.5 L/min) in 1V CHD. RESULTS: Twenty-one ferumoxytol-enhanced and 23 gadolinium-enhanced CMR studies were included, with no difference in age (2.1 ± 1.6 vs. 2.3 ± 1.9 years, p = 0.70), patient body surface area (0.50 ± 0.2 vs. 0.52 ± 0.2 m2, p = 0.67), or vessel diameter (11.4 ± 5.2 vs. 12.4 ± 5.6 mm, p = 0.22). Ten CMR studies with single ventricular CHD were included. Overall, ferumoxytol-enhanced 4D flow CMR measurements demonstrated less percent difference to 2D-PC when compared to gadolinium-enhanced 4D Flow CMR studies. In subgroup analyses of arterial vs. venous flows (high velocity vs. low velocity) and low flow in single ventricle CHD, ferumoxytol-enhanced 4D Flow CMR measurements had stronger correlation to 2D-PC CMR. The contrast-to-noise ratio (CNR) in ferumoxytol-enhanced studies was higher than the CNR in gadolinium-enhanced studies. CONCLUSIONS: Ferumoxytol-enhanced 4D Flow CMR has improved accuracy when compared to gadolinium 4D Flow CMR, particularly for infants with small vessels in CHD.


Assuntos
Gadolínio , Cardiopatias Congênitas , Criança , Lactente , Humanos , Óxido Ferroso-Férrico , Estudos Retrospectivos , Velocidade do Fluxo Sanguíneo , Valor Preditivo dos Testes , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes
8.
Am J Physiol Heart Circ Physiol ; 323(3): H449-H460, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35839154

RESUMO

Patients with repaired tetralogy of Fallot (rTOF) can develop chronic pulmonary insufficiency (PI) with right ventricular (RV) dilation, progressive RV dysfunction, and decreased exercise capacity. Pulmonary valve replacement (PVR) can help reduce the amount of PI and RV dilation; however, optimal timing remains controversial; a better understanding of rTOF pathophysiology is of fundamental importance to inform clinical management of patients with rTOF and optimal timing of PVR. In this study, we hypothesize a tight interplay between RV shape, intracardiac biomechanics, and ventricular function in patients with rTOF. To explore this hypothesis and derive quantitative measures, we combined statistical shape modeling with physics-based analysis of in vivo 4D flow data in 36 patients with rTOF. Our study demonstrated for the first time a correlation between regional RV shape variations, hemodynamic forces (HDF), and clinical dysfunction in patients with rTOF. The main findings of this work include 1) general increase in RV size, due to both volume overload and physiological growth, correlated with decrease in strain magnitude in the respective directions, and with increased QRS; 2) regional PI-induced remodeling accounted for ∼10% of the shape variability of the population, and was associated with increased diastolic HDF along the diaphragm-to-right ventricular outflow tract (RVOT) direction, resulting in a net RV deformation along the same direction and decreased tricuspid annular plane systolic excursion (TAPSE); and 3) three shape modes independently correlated with systolic HDF and exercise capacity. Identification of patients based on the shape variations described in this study could help identify those at risk for irreversible dysfunction and guide optimal timing of PVR.NEW & NOTEWORTHY We combine statistical shape modeling with physics-based analysis of 4D flow data to elucidate the interplay between RV shape, hemodynamic forces, and clinical dysfunction in repaired tetralogy of Fallot. We are the first to show that ventricular remodeling is related to hemodynamic force magnitude and direction, global and regional functional parameters, and exercise intolerance. Identification of patients based on the shape variations described in this study could help identify those at risk for irreversible dysfunction.


Assuntos
Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Ventrículos do Coração , Hemodinâmica , Humanos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita/fisiologia
9.
Circ Cardiovasc Imaging ; 15(1): e012242, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34983186

RESUMO

Parametric mapping, that is, a pixel-wise map of magnetic relaxation parameters, expands the diagnostic potential of cardiac magnetic resonance by enabling quantification of myocardial tissue-specific magnetic relaxation on an absolute scale. Parametric mapping includes T1 mapping (native and postcontrast), T2 and T2* mapping, and extracellular volume measurements. The myocardial composition is altered in various disease states affecting its inherent magnetic properties and thus the myocardial relaxation times that can be directly quantified using parametric mapping. Parametric mapping helps in the diagnosis of nonfocal disease states and allows for longitudinal disease monitoring, evaluating therapeutic response (as in Thalassemia patients with iron overload undergoing chelation), and risk-stratification of certain diseases. In this review article, we describe various mapping techniques and their clinical utility in congenital heart disease. We will also review the available literature on normative values in children, the strengths, and weaknesses of these techniques. This review provides a starting point for pediatric cardiologists to understand and implement parametric mapping in their practice.


Assuntos
Cardiologia , Cardiopatias Congênitas/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Criança , Humanos , Valor Preditivo dos Testes
11.
Cardiol Young ; 32(5): 718-726, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34348808

RESUMO

BACKGROUND: A novel paediatric disease, multi-system inflammatory syndrome in children, has emerged during the 2019 coronavirus disease pandemic. OBJECTIVES: To describe the short-term evolution of cardiac complications and associated risk factors in patients with multi-system inflammatory syndrome in children. METHODS: Retrospective single-centre study of confirmed multi-system inflammatory syndrome in children treated from 29 March, 2020 to 1 September, 2020. Cardiac complications during the acute phase were defined as decreased systolic function, coronary artery abnormalities, pericardial effusion, or mitral and/or tricuspid valve regurgitation. Patients with or without cardiac complications were compared with chi-square, Fisher's exact, and Wilcoxon rank sum. RESULTS: Thirty-nine children with median (interquartile range) age 7.8 (3.6-12.7) years were included. Nineteen (49%) patients developed cardiac complications including systolic dysfunction (33%), valvular regurgitation (31%), coronary artery abnormalities (18%), and pericardial effusion (5%). At the time of the most recent follow-up, at a median (interquartile range) of 49 (26-61) days, cardiac complications resolved in 16/19 (84%) patients. Two patients had persistent mild systolic dysfunction and one patient had persistent coronary artery abnormality. Children with cardiac complications were more likely to have higher N-terminal B-type natriuretic peptide (p = 0.01), higher white blood cell count (p = 0.01), higher neutrophil count (p = 0.02), severe lymphopenia (p = 0.05), use of milrinone (p = 0.03), and intensive care requirement (p = 0.04). CONCLUSION: Patients with multi-system inflammatory syndrome in children had a high rate of cardiac complications in the acute phase, with associated inflammatory markers. Although cardiac complications resolved in 84% of patients, further long-term studies are needed to assess if the cardiac abnormalities (transient or persistent) are associated with major cardiac events.


Assuntos
COVID-19 , Anormalidades Cardiovasculares , Doença da Artéria Coronariana , Derrame Pericárdico , COVID-19/complicações , Criança , Pré-Escolar , Humanos , Derrame Pericárdico/etiologia , Estudos Retrospectivos , SARS-CoV-2 , Síndrome de Resposta Inflamatória Sistêmica
12.
Cardiovasc Eng Technol ; 13(1): 41-54, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34169460

RESUMO

PURPOSE: Patients with repaired Tetralogy of Fallot (rTOF) will develop dilation of the right ventricle (RV) from chronic pulmonary insufficiency and require pulmonary valve replacement (PVR). Cardiac MRI (cMRI) is used to guide therapy but has limitations in studying novel intracardiac flow parameters. This pilot study aimed to demonstrate feasibility of reconstructing RV motion and simulating intracardiac flow in rTOF patients, exclusively using conventional cMRI and an immersed-boundary method computational fluid dynamic (CFD) solver. METHODS: Four rTOF patients and three normal controls underwent cMRI including 4D flow. 3D RV models were segmented from cMRI images. Feature-tracking software captured RV endocardial contours from cMRI long-axis and short-axis cine stacks. RV motion was reconstructed via diffeomorphic mapping (Deformetrica, deformetrica.org), serving as the domain boundary for CFD. Fully-resolved direct numerical simulations were performed over several cardiac cycles. Intracardiac vorticity, kinetic energy (KE) and turbulent kinetic energy (TKE) was measured. For validation, RV motion was compared to manual tracings, results of KE were compared between CFD and 4D flow. RESULTS: Diastolic vorticity and TKE in rTOF patients were 4.12 ± 2.42 mJ/L and 115 ± 27/s, compared to 2.96 ± 2.16 mJ/L and 78 ± 45/s in controls. There was good agreement between RV motion and manual tracings. The difference in diastolic KE between CFD and 4D flow by Bland-Altman analysis was - 0.89910 to 2 mJ/mL (95% limits of agreement: - 1.351 × 10-2 mJ/mL to 1.171 × 10-2 mJ/mL). CONCLUSION: This CFD framework can produce intracardiac flow in rTOF patients. CFD has the potential for predicting the effects of PVR in rTOF patients and improve the clinical indications guided by cMRI.


Assuntos
Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Simulação por Computador , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Projetos Piloto , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia
13.
J Cardiovasc Magn Reson ; 23(1): 108, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34629101

RESUMO

The Society for Cardiovascular Magnetic Resonance (SCMR) is an international society focused on the research, education, and clinical application of cardiovascular magnetic resonance (CMR). Case of the week is a case series hosted on the SCMR website ( https://www.scmr.org ) that demonstrates the utility and importance of CMR in the clinical diagnosis and management of cardiovascular disease. Each case consists of the clinical presentation and a discussion of the condition and the role of CMR in diagnosis and guiding clinical management. The cases are all instructive and helpful in the approach to patient management. We present a digital archive of the 2020 Case of the Week series of 11 cases as a means of further enhancing the education of those interested in CMR and as a means of more readily identifying these cases using a PubMed or similar search engine.


Assuntos
Doenças Cardiovasculares , Imageamento por Ressonância Magnética , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/terapia , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
14.
J Cardiovasc Magn Reson ; 23(1): 99, 2021 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-34482836

RESUMO

BACKGROUND: Coarctation of the aorta (CoA) is associated with decreased exercise capacity despite successful repair. Altered flow patterns have been identified due to abnormal aortic arch geometry. Our previous work demonstrated aorta size mismatch to be associated with exercise intolerance in this population. In this study, we studied aortic flow patterns during simulations of exercise in repaired CoA using 4D flow cardiovascular magnetic resonance (CMR) using aortic replicas connected to an in vitro flow pump and correlated findings with exercise stress test results to identify biomarkers of exercise intolerance. METHODS: Patients with CoA repair were retrospectively analyzed after CMR and exercise stress test. Each aorta was manually segmented and 3D printed. Pressure gradient measurements from ascending aorta (AAo) to descending aorta (DAo) and 4D flow CMR were performed during simulations of rest and exercise using a mock circulatory flow loop. Changes in wall shear stress (WSS) and secondary flow formation (vorticity and helicity) from rest to exercise were quantified, as well as estimated DAo Reynolds number. Parameters were correlated with percent predicted peak oxygen consumption (VO2max) and aorta size mismatch (DAAo/DDAo). RESULTS: Fifteen patients were identified (VO2max 47 to 126% predicted). Pressure gradient did not correlate with VO2max at rest or exercise. VO2max correlated positively with the change in peak vorticity (R = 0.55, p = 0.03), peak helicity (R = 0.54, p = 0.04), peak WSS in the AAo (R = 0.68, p = 0.005) and negatively with peak WSS in the DAo (R = - 0.57, p = 0.03) from rest to exercise. DAAo/DDAo correlated strongly with change in vorticity (R = - 0.38, p = 0.01), helicity (R = - 0.66, p = 0.007), and WSS in the AAo (R = - 0.73, p = 0.002) and DAo (R = 0.58, p = 0.02). Estimated DAo Reynolds number negatively correlated with VO2max for exercise (R = - 0.59, p = 0.02), but not rest (R = - 0.28, p = 0.31). Visualization of streamline patterns demonstrated more secondary flow formation in aortic arches with better exercise capacity, larger DAo, and lower Reynolds number. CONCLUSIONS: There are important associations between secondary flow characteristics and exercise capacity in repaired CoA that are not captured by traditional pressure gradient, likely due to increased turbulence and inefficient flow. These 4D flow CMR parameters are a target of investigation to identify optimal aortic arch geometry and improve long term clinical outcomes after CoA repair.


Assuntos
Coartação Aórtica , Aorta , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Estudos Retrospectivos
15.
J Cardiovasc Magn Reson ; 23(1): 98, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34412634

RESUMO

BACKGROUND: The global effect of chronic pulmonary regurgitation (PR) on right ventricular (RV) dilation and dysfunction in repaired Tetralogy of Fallot (rTOF) patients is well studied by cardiovascular magnetic resonance (CMR). However, the links between PR in the RV outflow tract (RVOT), RV dysfunction and exercise intolerance are not clarified by conventional measurements. Not all patients with RV dilation share the same intracardiac flow characteristics, now measurable by time resolved three-dimensional phase contrast imaging (4D flow). In our study, we quantified regional vorticity and energy loss in rTOF patients and correlated these parameters with RV dysfunction and exercise capacity. METHODS: rTOF patients with 4D flow datasets were retrospectively analyzed, including those with transannular/infundibular repair and conduit repair. Normal controls and RV dilation patients with atrial-level shunts (Qp:Qs > 1.2:1) were included for comparison. 4D flow was post-processed using IT Flow (Cardioflow, Japan). Systolic/diastolic vorticity (ω, 1/s) and viscous energy loss (VEL, mW) in the RVOT and RV inflow were measured. To characterize the relative influence of diastolic vorticity in the two regions, an RV Diastolic Vorticity Quotient (ωRVOT-Diastole/ωRV Inflow-Diastole, RV-DVQ) was calculated. Additionally, RVOT Vorticity Quotient (ωRVOT-Diastole/ωRVOT-Systole, RVOT-VQ) and RVOT Energy Quotient (VELRVOT-Diastole/VELRVOT-Systole, RVOT-EQ) was calculated. In rTOF, measurements were correlated against conventional CMR and exercise stress test results. RESULTS: 58 rTOF patients, 28 RV dilation patients and 12 controls were included. RV-DVQ, RVOT-VQ, and RVOT-EQ were highest in rTOF patients with severe PR compared to rTOF patients with non-severe PR, RV dilation and controls (p < 0.001). RV-DVQ positively correlated with RV end-diastolic volume (0.683, p < 0.001), PR fraction (0.774, p < 0.001) and negatively with RV ejection fraction (- 0.521, p = 0.003). Both RVOT-VQ, RVOT-EQ negatively correlated with VO2-max (- 0.587, p = 0.008 and - 0.617, p = 0.005) and % predicted VO2-max (- 0.678, p = 0.016 and - 0.690, p = 0.001). CONCLUSIONS: In rTOF patients, vorticity and energy loss dominate the RVOT compared to tricuspid inflow, correlating with RV dysfunction and exercise intolerance. These 4D flow-based measurements may be sensitive biomarkers to guide surgical management of rTOF patients.


Assuntos
Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita
16.
Interact Cardiovasc Thorac Surg ; 32(4): 658-660, 2021 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-33367810

RESUMO

An 8-year-old with a known diagnosis of an asymptomatic coronary artery fistula (CAF) presented with exertional syncope and haemopericardium due to contained rupture of CAF. A transcatheter closure was attempted, but the fistula ruptured again prompting emergency surgical repair. Spontaneous rupture is a catastrophic complication of CAF and warrants a high index of suspicion, timely diagnosis and team management.


Assuntos
Derrame Pericárdico , Criança , Angiografia Coronária , Anomalias dos Vasos Coronários , Fístula , Humanos , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Ruptura Espontânea , Síncope/etiologia , Resultado do Tratamento
17.
J Thorac Cardiovasc Surg ; 162(1): 183-192.e2, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33131888

RESUMO

OBJECTIVE: Coarctation of the aorta (CoA) is associated with decreased exercise capacity despite successful repair with no residual stenosis; however, the hemodynamic mechanism remains unknown. This study aims to correlate aortic arch geometry with exercise capacity in patients with successfully repaired CoA and explain hemodynamic changes using 3-dimensional-printed aorta models in a mock circulatory flow loop. METHODS: A retrospective chart review identified patients with CoA repair who had cardiac magnetic resonance imaging and an exercise stress test. Measurements included aorta diameters, arch height to diameter ratio, left ventricular function, and percent descending aorta (%DAo) flow. Each aorta was printed 3-dimensionally for the flow loop. Flow and pressure were measured at the ascending aorta (AAo) and DAo during simulated rest and exercise. Measurements were correlated with percent predicted peak oxygen consumption (VO2 max). RESULTS: Fifteen patients (mean age 26.8 ± 8.6 years) had a VO2 max between 47% and 126% predicted (mean 92 ± 20%) with normal left ventricular function. DAo diameter and %DAo flow positively correlated with VO2 (P = .007 and P = .04, respectively). AAo to DAo diameter ratio (DAAo/DDAo) negatively correlated with VO2 (P < .001). From flow loop simulations, the ratio of %DAo flow in exercise to rest negatively correlated with VO2 (P = .02) and positively correlated with DAAo/DDAo (P < .01). CONCLUSIONS: This study suggests aorta size mismatch (DAAo/DDAo) is a novel, clinically important measurement predicting exercise capacity in patients with successful CoA repair, likely due to increased resistance and altered flow distribution. Aorta size mismatch and %DAo flow are targets for further clinical evaluation in repaired CoA.


Assuntos
Aorta , Coartação Aórtica , Tolerância ao Exercício/fisiologia , Adolescente , Adulto , Aorta/diagnóstico por imagem , Aorta/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Criança , Feminino , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Estudos Retrospectivos , Adulto Jovem
18.
J Investig Med ; 68(8): 1364-1369, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32868378

RESUMO

Cardiac damage from chemotherapy is a known phenomenon leading to significant morbidity and mortality in the cancer surviving population, and identifying high-risk pediatric patients early is challenging. The purpose of this pilot study was to evaluate whether echo strain, cardiac MRI (CMR), and serum biomarkers are more sensitive methods for detecting cardiac toxicity than standard echo and to examine the relationship between biomarkers in patients without decreased systolic function as determined by standard echo. In this pilot study, we prospectively enrolled pediatric subjects after completion of anthracycline inclusive chemotherapy. Each subject underwent a post-treatment echocardiogram (standard with strain), serum biomarkers (N-terminal brain natriuretic peptide (NT-pro-BNP) and interleukin 1 receptor-like 1 protein (ST2)), and CMR (standard and extracellular volumes (ECVs)). We correlated the markers using Pearson correlation. We enrolled 30 subjects, 11F/19M, aged 8-21 years. Cumulative anthracycline dose (CAD) correlated with BNP (p=0.06), CMR ECV 4-chamber (p=0.05) and sagittal (p=0.01), and mitral valve E/A (p=0.02). BNP correlated with CMR ECV 4-chamber (p=0.001) and sagittal (p=0.001) and with echo average longitudinal strain (ALS) (p=0.05). This study demonstrated a significant correlation of CAD with BNP and CMR ECV. There was also a significant correlation of NT-pro-BNP with CMR ECV and ALS. Combining these parameters with standard echo has the potential to identify high-risk patients early. Further studies are needed for long-term follow-up and management in this vulnerable population.


Assuntos
Sobreviventes de Câncer , Miocárdio/patologia , Adolescente , Adulto , Antraciclinas/uso terapêutico , Biomarcadores/sangue , Criança , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Adulto Jovem
19.
Pediatr Radiol ; 50(12): 1709-1716, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32696111

RESUMO

BACKGROUND: The benefits of cardiac magnetic resonance imaging (MRI) in the pediatric population must be balanced with the risk and cost of anesthesia. Segmented imaging using multiple averages attempts to avoid breath-holds requiring general anesthesia; however, cardiorespiratory artifacts and prolonged scan times limit its use. Thus, breath-held imaging with general anesthesia is used in many pediatric centers. The advent of free-breathing, motion-corrected (MOCO) cines by real-time re-binned reconstruction offers reduced anesthesia exposure without compromising image quality. OBJECTIVE: This study evaluates sedation utilization in our pediatric cardiac MR practice before and after clinical introduction of free-breathing MOCO imaging for cine and late gadolinium enhancement. MATERIALS AND METHODS: In a retrospective study, patients referred for a clinical cardiac MR who would typically be offered sedation for their scan (n=295) were identified and divided into two eras, those scanned before the introduction of MOCO cine and late gadolinium enhancement sequences and those scanned following their introduction. Anesthesia use was compared across eras and disease-specific cohorts. RESULTS: The incidence of non-sedation studies performed in children nearly tripled following the introduction of MOCO imaging (25% [pre-MOCO] to 69% [post-MOCO], P<0.01), with the greatest effect in patients with simple congenital heart disease. Eleven percent of the post-MOCO cohort comprised infants younger than 3 months of age who could forgo sedation with the combination of MOCO imaging and a "feed-and-bundle" positioning technique. CONCLUSION: Implementation of cardiac MR with MOCO cine and late gadolinium enhancement imaging in a pediatric population is associated with significantly decreased sedation utilization.


Assuntos
Anestesia/estatística & dados numéricos , Meios de Contraste , Gadolínio , Cardiopatias/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Criança , Estudos de Coortes , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Respiração , Estudos Retrospectivos , Tempo
20.
J Cardiovasc Magn Reson ; 22(1): 11, 2020 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-32013998

RESUMO

INTRODUCTION: Pediatric z scores are necessary to describe size and structure of the heart in growing children, however, development of an accurate z score calculator requires robust normal datasets, which are difficult to obtain with cardiovascular magnetic resonance (CMR) in children. Motion-corrected (MOCO) cines from re-binned, reconstructed real-time cine offer a free-breathing, rapid acquisition resulting in cines with high spatial and temporal resolution. In combination with child-friendly positioning and entertainment, MOCO cine technique allows for rapid cine volumetry in patients of all ages without sedation. Thus, our aim was to prospectively enroll normal infants and children birth-12 years for creation and validation of a z score calculator describing normal right ventricular (RV) and left ventricular (LV) size. METHODS: With IRB approval and consent/assent, 149 normal children successfully underwent a brief noncontrast CMR on a 1.5 T scanner including MOCO cines in the short axis, and RV and LV volumes were measured. 20% of scans were re-measured for interobserver variability analyses. A general linear modeling (GLM) framework was employed to identify and properly represent the relationship between CMR-based assessments and anthropometric data. Scatter plots of model fit and Akaike's information criteria (AIC) results were used to guide the choice among alternative models. RESULTS: A total of 149 subjects aged 22 days-12 years (average 5.1 ± 3.6 years), with body surface area (BSA) range 0.21-1.63 m2 (average 0.8 ± 0.35 m2) were scanned. All ICC values were > 95%, reflecting excellent agreement between raters. The model that provided the best fit of volume measure to the data included BSA with higher order effects and gender as independent variables. Compared with earlier z score models, there is important additional growth inflection in early toddlerhood with similar z score prediction in later childhood. CONCLUSIONS: Free-breathing, MOCO cines allow for accurate, reliable RV and LV volumetry in a wide range of infants and children while awake. Equations predicting fit between LV and RV normal values and BSA are reported herein for purposes of creating z scores. TRIAL REGISTRATION: clinicaltrials.gov NCT02892136, Registered 7/21/2016.


Assuntos
Desenvolvimento Infantil , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/crescimento & desenvolvimento , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Função Ventricular Direita , Fatores Etários , Criança , Pré-Escolar , Feminino , Voluntários Saudáveis , Humanos , Lactente , Recém-Nascido , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Vigília
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...