1.
Ultrasound Med Biol ; 39(1): 111-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23200180

RESUMO

We tested the hypothesis that neuropathic tissue is more sensitive to stimulation by intense focused ultrasound (iFU) than control tissue. We created a diffusely neuropathic paw in rats via partial ligation of the sciatic nerve, whose sensitivity to iFU stimulation we compared with sham-surgery and normal control paws. We then applied increasing amounts of iFU (individual 0.2 s pulses at 1.15 MHz) to the rats' paws, assaying for their reliable withdrawal from that stimulation. Neuropathic rats preferentially withdrew their injured paw from iFU at smaller values of iFU intensity (84.2 W/cm(2) ± 25.5) than did sham surgery (97.7 W/cm(2) ± 11.9) and normal control (> 223 W/cm(2)) animals, with greater sensitivity and specificity (85% for neuropathic rats and 50% each of sham surgery and normal control rats). These results directly support our hypothesis as well as Gavrilov's idea that doctors may some day use iFU stimulation to diagnose patients with neuropathies.


Assuntos
Neuralgia/fisiopatologia , Limiar da Dor , Ultrassom , Animais , Membro Posterior , Temperatura Alta , Luz , Neuralgia/diagnóstico , Ratos , Ratos Sprague-Dawley , Nervo Isquiático
2.
Ultrasound Med Biol ; 30(2): 261-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14998678

RESUMO

Our previous study showed that high-intensity focused ultrasound (HIFU) is capable of producing "primary acoustic hemostasis" in the form of ultrasound (US)-induced platelet activation, aggregation and adhesion to a collagen-coated surface. In the current study, 1.1 MHz continuous-wave HIFU was used to investigate the role of cavitation as a mechanism for platelet aggregation in samples of platelet-rich plasma. A 5 MHz passive cavitation detector was used to monitor cavitation activity and laser aggregometry was used to measure platelet aggregation. Using spatial average intensities from 0 to 3350 W/cm2, the effects of HIFU-induced cavitation on platelet aggregation were investigated by enhancing cavitation activity through use of US contrast agents and by limiting cavitation activity through use of an overpressure system. Our results show that increased cavitation activity lowers the intensity threshold to produce platelet aggregation and decreased cavitation activity in the overpressure system raises the intensity threshold for platelet aggregation.


Assuntos
Agregação Plaquetária/fisiologia , Ultrassonografia/métodos , Albuminas , Coagulação Sanguínea/fisiologia , Meios de Contraste , Humanos , Pressão