Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Vet Res ; 84(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36881500

RESUMO

OBJECTIVE: To compare the elution characteristics of amikacin-impregnated calcium sulfate (CaSO4) beads based on different drug concentrations and bead size configurations. SAMPLE: Six groups of amikacin-impregnated CaSO4 beads and one negative control group. PROCEDURES: Amikacin-impregnated CaSO4 beads were formed with either 500 mg (low-concentration) or 1 g (high-concentration) of amikacin per 15 g CaSO4 hemihydrate powder. The number of beads necessary to approximate 150 mg of amikacin for each of the 3 bead sizes (3 mm, 5 mm, and 7 mm) at both low and high concentrations were placed in 6 mL of phosphate-buffered saline. The saline was sampled at 14 time points over 28 days. Amikacin concentrations were determined using liquid chromatography-mass spectrometry. RESULTS: Smaller beads reached higher mean peak concentrations than larger beads (P < .0006). Peak concentrations for the low- and high-concentration groups were 20.5 mg/mL and 27.4 mg/mL, 13.1 mg/mL and 14.0 mg/mL, and 8.85 mg/mL and 6.75 mg/mL for the 3 mm, 5 mm, and 7 mm beads, respectively. Bead size also affected the length of therapeutic duration, lasting 6 days for the 3 mm and 5 mm beads and 9 days for the 7 mm beads. However, this was only statistically evident among the high-concentration beads (P < .044). Antimicrobial concentration within the same bead sizes did not affect elution. CLINICAL RELEVANCE: Amikacin-impregnated CaSO4 beads achieved extreme supratherapeutic eluent concentrations. While additional studies are needed, bead size significantly affected elution with smaller beads reaching higher peak concentrations and 7 mm, high-concentration beads demonstrating a longer therapeutic duration than smaller beads.


Assuntos
Amicacina , Anti-Infecciosos , Animais , Sulfato de Cálcio/química , Antibacterianos
2.
J Vet Intern Med ; 32(2): 701-706, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29460333

RESUMO

BACKGROUND: Diagnostic accuracy of the 3 mm laparoscopic cup biopsy forceps for collection of tissue samples from canine livers is unproven. HYPOTHESES/OBJECTIVES: Compare sample surface area and portal triad count between 3 mm and 5 mm laparoscopic cup biopsies and compare the histologic diagnosis obtained by each instrument to a standard necropsy wedge. The hypothesis was that more portal triads and greater sample surface area would be found with the 5 mm samples and the laparoscopic instruments would not have significantly different levels of agreement with necropsy wedge diagnosis. ANIMALS: Twenty-one client-owned dogs undergoing necropsy. METHODS: Prospective ex vivo study. Three samples (3 mm, 5 mm, and wedge) were taken of 2 different hepatic divisions within 24 hours of death. Morphologic diagnosis, World Small Animal Veterinary Association histologic features, surface area, and portal triad numbers were compared among the 3 samples. RESULTS: There were significantly more portal triads (mean 21.4 versus 13.8; P < .0001) and a higher surface area (20.3 mm2 versus 11.5 mm2 ; P < .0001) in the 5 mm samples compared to 3 mm samples. Kappa coefficients and percent agreement for histologic diagnosis as compared to the wedge biopsy were not significantly different between the 2 instrument sizes (κ = 0.383 and 0.436, respectively; 67% and 69%, respectively). CONCLUSIONS AND CLINICAL IMPORTANCE: Despite yielding smaller sample sizes, the 3 mm laparoscopic cup biopsy has a similar level of histologic diagnostic accuracy to the 5 mm instrument.


Assuntos
Biópsia/veterinária , Doenças do Cão/patologia , Animais , Biópsia/instrumentação , Biópsia/métodos , Doenças do Cão/diagnóstico , Cães , Feminino , Laparoscopia/veterinária , Hepatopatias/diagnóstico , Hepatopatias/patologia , Masculino , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...