Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Epilepsia Open ; 8(4): 1503-1511, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37750050

RESUMO

OBJECTIVE: Single-photon emission computed tomography (SPECT) with the tracer 99m Tc-HMPAO is a method to visualize the cerebral hyperperfusion during an epileptic seizure and thus localize the epileptogenic zone and seizure propagation. Subtraction of interictal from Ictal SPECT Co-registered to MRI (SISCOM) visualizes areas with relative increases in cerebral blood flow. The purpose of this retrospective study is to explore the added value of visualizing areas of hypoperfusion as well as hyperperfusion, so-called reversed SISCOM. METHODS: Fifty-six patients operated for epilepsy who had been investigated with SISCOM were included in the analysis. The patients were divided into two groups based on seizure duration after tracer injection, above or below 30 s. The preoperative SISCOM description was compared to the area of resection and given a concordance score. The 56 SISCOM were recalculated visualizing also areas of hypoperfusion and again compared to the site of resection using the same scale of concordance. The reversed SISCOM were categorized into three subgroups: "Altered Conclusion," "Confirmed Conclusion," and "Adds Nothing." If an area of hyperperfusion had an area of hypoperfusion in close proximity, it was re-interpreted as noise, thus possibly altering the conclusion. If the areas of hypoperfusion were in the opposite hemisphere it was interpreted as confirming factor. Further the concordance scores from conventional SISCOM and reversed SISCOM was compared to surgical outcome to explore the difference in sensitivity, positive predictive value (PPV), and odds ratio. RESULTS: In approximately half of the cases reversed SISCOM added additional value, meaning either altered the conclusion or confirmed the conclusion. The sensitivity, PPV, and odds ratio was also better in the subgroup of long, >30 s seizure duration after injection, and got worse in the group with short, <30 s seizure duration after injection. SIGNIFICANCE: Adding reversed SISCOM performed better than conventional SISCOM at predicting good surgical outcome.


Assuntos
Epilepsia , Humanos , Estudos Retrospectivos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio Tc 99m Exametazima , Convulsões/diagnóstico por imagem , Convulsões/cirurgia
2.
Epilepsia Open ; 8(3): 1064-1074, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37464953

RESUMO

OBJECTIVE: This retrospective study investigates the predictive value of ictal subtraction single-photon emission computed tomography (SPECT) co-registered to magnetic resonance imaging (MRI) (SISCOM) for successful epilepsy surgery. METHODS: 57 patients examined with SISCOM as a part of epilepsy surgery evaluation were divided into two groups based on seizure duration after tracer injection (group 1: Seizure duration above or equal to 30 s, group 2: Seizure duration under 30 s). SISCOM was compared to the surgical site and categorized as good or poor concordance. Subsequently, Odds ratios (ORs) and positive predictive values (PPVs) were calculated for each group for good surgical outcome, freedom from disabling seizures. RESULTS: The PPVs and ORs for good surgical outcome was 74.1% and 5.71 for group 1 and 40% and 0.22 for group 2. SISCOM had a similar positive predictive value regardless of whether the focus was in the same or neighboring lobe, but same hemisphere as the resection. CONCLUSION: In conclusion, the implementation of a precise definition for a well-executed ictal SPECT scan with respect to seizure duration after injection enhances the positive predictive value (PPV) and odds ratio (OR) for successful surgical outcome, surpassing previous findings, whether the focus in resected lobe or the neighboring.


Assuntos
Epilepsia , Humanos , Estudos Retrospectivos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Convulsões/diagnóstico por imagem , Convulsões/cirurgia , Tecnécio Tc 99m Exametazima
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...