Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BJUI Compass ; 5(4): 439-446, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38633824

RESUMO

Objective: The objective of this study is to assess the impact of overnight environmental conditions on erectile penile temperature within a controlled setting, with the aim of investigating the feasibility of using temperature measurements for nocturnal erection detection in erectile dysfunction diagnostics. Subjects/patients and methods: We conducted a proof-of-concept study involving 10 healthy male participants aged 20 to 25. The study was carried out at the Department of Urology, St. Antonius Ziekenhuis, the Netherlands. Penile temperature thermistor measurements were taken during visually aroused erections of participants in naked state and in simulated overnight condition (underwear and blankets). Main outcome variables were peak and baseline temperature during erectile periods. To minimize the impact of differences in erectile strength and duration between consecutive measurements, we applied randomization to the order of the environmental conditions. Results: We observed a significant increase in penile temperature during erection in both the naked (p < 0.01) and simulated overnight condition (p < 0.01). The mean temperature increase was 1.70 and 0.67°C, respectively. While penile temperature returned to baseline immediately after naked erections, the 'Staying Hot effect' was noted in the simulated overnight condition measurements, where the temperature remained elevated at peak temperature for the entire 30-min period following the erection. Conclusions: The findings from this study indicate that the penile temperature not only significantly increases during naked sexual arousal but is also detectable under simulated overnight conditions. This underscores the potential of using temperature measurements for nocturnal erection detection, representing a crucial initial step in developing a modernized, non-invasive sensor system for ambulatory erectile dysfunction diagnostics. Further research, including an overnight study, is needed to gain insights into the feasibility of utilizing penile temperature measurements for nocturnal erection detection and to assess the impact of the 'Staying Hot effect' on subsequent erection detection.

2.
ACS Omega ; 8(8): 7587-7594, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36872992

RESUMO

The control of acidity drives the assembly of biopolymers that are essential for a wide range of applications. Its miniaturization can increase the speed and the possibilities of combinatorial throughput for their manipulation, similar to the way that the miniaturization of transistors allows logical operations in microelectronics with a high throughput. Here, we present a device containing multiplexed microreactors, each one enabling independent electrochemical control of acidity in ∼2.5 nL volumes, with a large acidity range from pH 3 to 7 and an accuracy of at least 0.4 pH units. The attained pH within each microreactor (with footprints of ∼0.3 mm2 for each spot) was kept constant for long retention times (∼10 min) and over repeated cycles of >100. The acidity is driven by redox proton exchange reactions, which can be driven at different rates influencing the efficiency of the device in order to achieve more charge exchange (larger acidity range) or better reversibility. The achieved performance in acidity control, miniaturization, and the possibility to multiplex paves the way for the control of combinatorial chemistry through pH- and acidity-controlled reactions.

3.
Anal Chem ; 95(11): 4889-4895, 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36881563

RESUMO

The performance of liquid chromatography operation in open-tubular channels, the ideal chromatographic column format, is limited by slow mass transport between the mobile and stationary phase. We recently introduced a lateral mixing methodology ("vortex chromatography") to reduce Taylor-Aris dispersion by employing (small) AC-EOF (alternating current electroosmotic flow) fields oriented perpendicular to the conventionally applied, axially oriented pressure gradient, resulting in the reduction of the C-term by a factor of 3, studied in 40 × 20 µm2 (aspect ratio (AR) = 2) channels under unretained conditions. In the present contribution, a further increased performance gain for channel dimensions relevant for chromatographic applications is demonstrated. The impact of the applied voltage and salt concentration is studied for 3 × 20 and 5 × 20 µm2 channels in ARs of up to 6.7, revealing a C-term reduction potential of a factor of up to 5 for large molecules (dextran) under unretained conditions. The decrease in κaris in a 5 µm channel (reduction of 80%) was larger than the decrease in a 3 µm channel (reduction of 44%).

4.
Glob Chall ; 7(3): 2200151, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36910468

RESUMO

Calcifying algae, like coccolithophores, greatly contribute to the oceanic carbon cycle and are therefore of particular interest for ocean carbon models. They play a key role in two processes that are important for the effective CO2 flux: The organic carbon pump (photosynthesis) and the inorganic carbon pump (calcification). The relative contribution of calcification and photosynthesis can be measured in algae by the amount of particulate inorganic carbon (PIC) and particulate organic carbon (POC). A microfluidic impedance cytometer is presented, enabling non-invasive and high-throughput assessment of the calcification state of single coccolithophore cells. Gradual modification of the exoskeleton by acidification results in a strong linear fit (R 2 = 0.98) between the average electrical phase and the PIC:POC ratio of the coccolithophore Emiliania huxleyi 920/9. The effect of different CO2 treatments on the PIC:POC ratio, however, is inconclusive, indicating that there is no strong effect observed for this particular strain. Lower PIC:POC ratios in cultures that grew to higher cell densities are found, which are also recorded with the impedance-based PIC:POC sensor. The development of this new quantification tool for small volumes paves the way for high-throughput analysis while applying multi-variable environmental stressors to support projections of the future marine carbon cycle.

5.
Cytometry A ; 103(3): 221-226, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36908134

RESUMO

The assessment of particle and cell size in electrical microfluidic flow cytometers has become common practice. Nevertheless, in flow cytometers with coplanar electrodes accurate determination of particle size is difficult, owing to the inhomogeneous electric field. Pre-defined signal templates and compensation methods have been introduced to correct for this positional dependence, but are cumbersome when dealing with irregular signal shapes. We introduce a simple and accurate post-processing method without the use of pre-defined signal templates and compensation functions using supervised machine learning. We implemented a multiple linear regression model and show an average reduction of the particle diameter variation by 37% with respect to an earlier processing method based on a feature extraction algorithm and compensation function. Furthermore, we demonstrate its application in flow cytometry by determining the size distribution of a population of small (4.6 ± 0.9 µm) and large (5.9 ± 0.8 µm) yeast cells. The improved performance of this coplanar, two electrode chip enables precise cell size determination in easy to fabricate impedance flow cytometers.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Microfluídica/métodos , Citometria de Fluxo/métodos , Impedância Elétrica , Tamanho da Partícula , Aprendizado de Máquina Supervisionado , Técnicas Analíticas Microfluídicas/métodos
6.
Biosensors (Basel) ; 12(9)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36140064

RESUMO

Microfluidics and lab-on-chip technologies have been used in a wide range of biomedical applications. They are known as versatile, rapid, and low-cost alternatives for expensive equipment and time-intensive processing. The veterinary industry and human fertility clinics could greatly benefit from label-free and standardized methods for semen analysis. We developed a tool to determine the acrosome integrity of spermatozoa using microfluidic impedance cytometry. Spermatozoa from boars were treated with the calcium ionophore A23187 to induce acrosome reaction. The magnitude, phase and opacity of individual treated and non-treated (control) spermatozoa were analyzed and compared to conventional staining for acrosome integrity. The results show that the opacity at 19 MHz over 0.5 MHz is associated with acrosome integrity with a cut-off threshold at 0.86 (sensitivity 98%, specificity 97%). In short, we have demonstrated that acrosome integrity can be determined using opacity, illustrating that microfluidic impedance cytometers have the potential to become a versatile and efficient alternative in semen analysis and for fertility treatments in the veterinary industry and human fertility clinics.


Assuntos
Acrossomo , Microfluídica , Animais , Calcimicina/farmacologia , Ionóforos de Cálcio , Impedância Elétrica , Humanos , Masculino , Espermatozoides , Suínos
7.
Sensors (Basel) ; 22(15)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35957340

RESUMO

Label-free field-effect transistor-based immunosensors are promising candidates for proteomics and peptidomics-based diagnostics and therapeutics due to their high multiplexing capability, fast response time, and ability to increase the sensor sensitivity due to the short length of peptides. In this work, planar junctionless field-effect transistor sensors (FETs) were fabricated and characterized for pH sensing. The device with SiO2 gate oxide has shown voltage sensitivity of 41.8 ± 1.4, 39.9 ± 1.4, 39.0 ± 1.1, and 37.6 ± 1.0 mV/pH for constant drain currents of 5, 10, 20, and 50 nA, respectively, with a drain to source voltage of 0.05 V. The drift analysis shows a stability over time of -18 nA/h (pH 7.75), -3.5 nA/h (pH 6.84), -0.5 nA/h (pH 4.91), 0.5 nA/h (pH 3.43), corresponding to a pH drift of -0.45, -0.09, -0.01, and 0.01 per h. Theoretical modeling and simulation resulted in a mean value of the surface states of 3.8 × 1015/cm2 with a standard deviation of 3.6 × 1015/cm2. We have experimentally verified the number of surface sites due to APTES, peptide, and protein immobilization, which is in line with the theoretical calculations for FETs to be used for detecting peptide-protein interactions for future applications.


Assuntos
Técnicas Biossensoriais , Transistores Eletrônicos , Técnicas Biossensoriais/métodos , Eletricidade , Imunoensaio , Dióxido de Silício
8.
J Chromatogr A ; 1670: 462970, 2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35339019

RESUMO

Acoustically induced secondary flows are applied to enhance lateral mass transfer beyond the relatively slow diffusion. This has the goal to reduce convective axial dispersion and the resulting band broadening which, in turn, limits the performance of column chromatography. Traditional approaches based on Taylor-Aris model are limited to one-dimensional rectilinear (unidirectional) tube- or channel-flows. We therefore apply the generalized dispersion theory (GDT) allowing for prediction of the dependence of potentially improved performance on the characteristics of the induced secondary flow, channel geometry and solute properties as well as providing qualitative physical insight into the role of lateral flows. Results corroborate agreement with our experimental observations (residual standard deviation, Sres = 3.88) and demonstrate the advantage of applying GDT relative to 3D time-dependent simulations.


Assuntos
Cromatografia , Cromatografia/métodos , Difusão , Soluções
9.
Biosensors (Basel) ; 11(10)2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34677309

RESUMO

Microfluidic impedance flow cytometers enable high-throughput, non-invasive, and label-free detection of single-cells. Cytometers with coplanar electrodes are easy and cheap to fabricate, but are sensitive to positional differences of passing particles, owing to the inhomogeneous electric field. We present a novel particle height compensation method, which employs the dependence of measured electrical opacity on particle height. The measured electrical opacity correlates with the particle height as a result of the constant electrical double layer series capacitance of the electrodes. As an alternative to existing compensation methods, we use only two coplanar electrodes and multi-frequency analysis to determine the particle size of a mixture of 5, 6, and 7 µm polystyrene beads with an accuracy (CV) of 5.8%, 4.0%, and 2.9%, respectively. Additionally, we can predict the bead height with an accuracy of 1.5 µm (8% of channel height) using the measured opacity and we demonstrate its application in flow cytometry with yeast. The use of only two electrodes is of special interest for simplified, easy-to-use chips with a minimum amount of instrumentation and of limited size.


Assuntos
Técnicas Analíticas Microfluídicas , Impedância Elétrica , Eletrodos , Desenho de Equipamento , Citometria de Fluxo , Dispositivos Lab-On-A-Chip , Microfluídica , Tamanho da Partícula , Poliestirenos
10.
Anal Chem ; 93(37): 12740-12747, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34495637

RESUMO

Over the last 3 decades, electrochemistry (EC) has been successfully applied in phase I and phase II metabolism simulation studies. The electrochemically generated phase I metabolite-like oxidation products can react with selected reagents to form phase II conjugates. During conjugate formation, the generation of isomeric compounds is possible. Such isomeric conjugates are often separated by high-performance liquid chromatography (HPLC). Here, we demonstrate a powerful approach that combines EC with ion mobility spectrometry to separate possible isomeric conjugates. In detail, we present the hyphenation of a microfluidic electrochemical chip with an integrated mixer coupled online to trapped ion mobility spectrometry (TIMS) and time-of-flight high-resolution mass spectrometry (ToF-HRMS), briefly chipEC-TIMS-ToF-HRMS. This novel method achieves results in several minutes, which is much faster than traditional separation approaches like HPLC, and was applied to the drug paracetamol and the controversial feed preservative ethoxyquin. The analytes were oxidized in situ in the electrochemical microfluidic chip under formation of reactive intermediates and mixed with different thiol-containing reagents to form conjugates. These were analyzed by TIMS-ToF-HRMS to identify possible isomers. It was observed that the oxidation products of both paracetamol and ethoxyquin form two isomeric conjugates, which are characterized by different ion mobilities, with each reagent. Therefore, using this hyphenated technique, it is possible to not only form reactive oxidation products and their conjugates in situ but also separate and detect these isomeric conjugates within only a few minutes.


Assuntos
Etoxiquina , Espectrometria de Mobilidade Iônica , Acetaminofen , Eletroquímica , Espectrometria de Massas , Microfluídica
11.
Lab Chip ; 21(16): 3105-3111, 2021 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-34259276

RESUMO

Classically, the configuration of electrodes (conductors) is used as a means to determine AC-electroosmotic flow patterns. In this paper, we use the configuration of insulator materials to achieve AC-electroosmotic flow patterning in a novel approach. We apply AC electric fields between parallel electrodes situated on the top and bottom of a microfluidic channel and separated by an insulating material. Channels of various cross-sectional shapes (e.g. rectangular and parallelogram) were fabricated by shaping the insulating material between the electrodes. We found that vortex flow patterns are induced depending on the cross-sectional shape of the channel. A bell-shaped design with non-orthogonal corners gave rise to 2 vortices, whereas in a channel with a parallelogram shaped cross-section, only a single vortex was observed. The vortices were experimentally observed by analysing the 3D trajectories of fluorescent microparticles. From a theoretical analysis, we conclude that flow shaping is primarily caused by shaping the electrical field lines in the channel.

12.
Sensors (Basel) ; 21(4)2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33670743

RESUMO

A ruthenium oxide (RuOx) electrode was used to monitor contractile events of human pluripotent stem cells-derived cardiomyocytes (hPSC-CMs) through electrical impedance spectroscopy (EIS). Using RuOx electrodes presents an advantage over standard thin film Pt electrodes because the RuOx electrodes can also be used as electrochemical sensor for pH, O2, and nitric oxide, providing multisensory functionality with the same electrode. First, the EIS signal was validated in an optically transparent well-plate setup using Pt wire electrodes. This way, visual data could be recorded simultaneously. Frequency analyses of both EIS and the visual data revealed almost identical frequency components. This suggests both the EIS and visual data captured the similar events of the beating of (an area of) hPSC-CMs. Similar EIS measurement was then performed using the RuOx electrode, which yielded comparable signal and periodicity. This mode of operation adds to the versatility of the RuOx electrode's use in in vitro studies.


Assuntos
Eletrodos , Miócitos Cardíacos , Óxidos , Rutênio , Impedância Elétrica , Humanos , Miócitos Cardíacos/fisiologia
13.
ACS Sens ; 6(1): 267-274, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33371688

RESUMO

In vitro studies which focus on cellular metabolism can benefit from time-resolved readouts from the living cells. pH and O2 concentration are fundamental parameters upon which cellular metabolism is often inferred. This work demonstrates a novel use of a ruthenium oxide (RuOx) electrode for in vitro studies. The RuOx electrode was characterized to measure both pH and O2 using two different modes. When operated potentiometrically, continuous pH reading can be obtained, and O2 concentration can be measured chronoamperometrically. In this work, we demonstrate the use of the RuOx electrodes in inferring two different types of metabolism of human pluripotent stem cell-derived cardiomyocytes. We also show and discuss the interpretation of the measurements into meaningful extracellular acidification rates and oxygen consumption rates of the cells. Overall, we present the RuOx electrode as a versatile and powerful tool in in vitro cell metabolism studies, especially in comparative settings.


Assuntos
Miócitos Cardíacos , Células-Tronco Pluripotentes , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Óxidos
14.
Biosens Bioelectron ; 173: 112808, 2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33221507

RESUMO

Since the industrial revolution 30% of the anthropogenic CO2 is absorbed by oceans, resulting in ocean acidification, which is a threat to calcifying algae. As a result, there has been profound interest in the study of calcifying algae, because of their important role in the global carbon cycle. The coccolithophore Emiliania huxleyi is considered to be globally the most dominant calcifying algal species, which creates a unique exoskeleton from inorganic calcium carbonate platelets. The PIC (particulate inorganic carbon): POC (particulate organic carbon) ratio describes the relative amount of inorganic carbon in the algae and is a critical parameter in the ocean carbon cycle. In this research we explore the use of microfluidic single-cell impedance spectroscopy in the field of calcifying algae. Microfluidic impedance spectroscopy enables us to characterize single-cell electrical properties in a non-invasive and label-free way. We use the ratio of the impedance at high frequency vs. low frequency, known as opacity, to discriminate between calcified coccolithophores and coccolithophores with a calcite exoskeleton dissolved by acidification (decalcified). We have demonstrated that using opacity we can discriminate between calcified and decalcified coccolithophores with an accuracy of 94.1%. We have observed a correlation between the measured opacity and the cell height in the channel, which is supported by FEM simulations. The difference in cell density between calcified and decalcified cells can explain the difference in cell height and therefore the measured opacity.

15.
Lab Chip ; 20(21): 3938-3947, 2020 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-32975255

RESUMO

Chromatographic columns are suffering from Taylor-Aris dispersion, especially for slowly diffusing molecules such as proteins. Since downscaling the channel size to reduce Taylor-Aris dispersion meets fundamental pressure limitations, new strategies are needed to further improve chromatography beyond its current limits. In this work we demonstrate a method to reduce Taylor-Aris dispersion by lateral mixing in a newly designed silicon AC-electroosmotic flow mixer. We obtained a reduction in κaris by a factor of three in a 40 µm × 20 µm microchannel, corresponding to a plate height gain of 2 to 3 under unretained conditions at low to high Pe values. We also demonstrate an improvement of a reverse-phase chromatographic separation of coumarins.

17.
Analyst ; 145(7): 2482-2509, 2020 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-31998878

RESUMO

The combination of electrochemistry and spectroscopy, known as spectroelectrochemistry (SEC), is an already established approach. By combining these two techniques, the relevance of the data obtained is greater than what it would be when using them independently. A number of review papers have been published on this subject, mostly written for experts in the field and focused on recent advances. In this review, written for both the novice in the field and the more experienced reader, the focus is not on the past but on the future. The scope is narrowed down to four techniques the authors claim to have the most potential for the future, namely: infrared spectroelectrochemistry (IR-SEC), Raman spectroelectrochemistry (Raman-SEC), nuclear magnetic resonance spectroelectrochemistry (NMR-SEC) and, perhaps slightly more controversial but certainly promising, electrochemistry mass-spectrometry (EC-MS).

18.
Biophys Rev ; 11(5): 757-763, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31588960

RESUMO

We present a review of field effect transistors (FET) from the point of view of their applications to label-free sensing in the era of genomics and proteomics. Here, rather than a collection of Bio-FET achievements, we propose an analysis of the different issues hampering the use of these devices into clinical applications. We make a particular emphasis on the influence of the sensor geometry in the phenomena of mass transport of analytes, which is a topic that has been traditionally overlooked in the analysis and design of biosensors, but that plays a central role in the achievement of low limits of detection. Other issues like the screening of charges by the ions in liquids with physiological ionic strength and the non-specific binding are also reviewed. In conclusion, we give an overview of different solutions that have been proposed to address all these challenges, demonstrating the potential of field effect transistors owing to their ease of integration with other semiconductor components for developing cost-effective, highly multiplexed sensors for next-generation medicines.

19.
Langmuir ; 35(30): 9704-9712, 2019 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-31310544

RESUMO

Microparticle porosity is normally determined in bulk manner providing an ensemble average that hinders establishing the individual role of each microparticle. On the other hand, single particle characterization implies expensive technology. We propose to use ion concentration polarization to measure differences in mesoporosity at the single particle level. Ion concentration polarization occurs at the interface between an electrolyte and a porous particle when an electric field is applied. The extent of ion concentration polarization depends, among others, on the mesopore size and density. By using a fluorescence marker, we could measure differences in concentration polarization between particles with 3 and 13 nm average mesopore diameters. A qualitative model was developed in order to understand and interpret the phenomena. We believe that this inexpensive method could be used to measure differences in mesoporous particle materials such as catalysts.

20.
Nano Lett ; 19(5): 2879-2887, 2019 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-31014066

RESUMO

The development of next generation medicines demands more sensitive and reliable label-free sensing able to cope with increasing needs of multiplexing and shorter times to results. Field effect transistor-based biosensors emerge as one of the main possible technologies to cover the existing gap. The general trend for the sensors has been miniaturization with the expectation of improving sensitivity and response time but presenting issues with reproducibility and noise level. Here we propose a Fin-Field Effect Transistor (FinFET) with a high height to width aspect ratio for electrochemical biosensing solving the issue of nanosensors in terms of reproducibility and noise, while keeping the fast response time. We fabricated different devices and characterized their performance with their response to the pH changes that fitted to a Nernst-Poisson model. The experimental data were compared with simulations of devices with different aspect ratio, establishing an advantage in linearity and lower device resistance to provide higher current signals for the FinFETs with higher aspect ratio. In addition, these FinFETs promise the optimization of reliability and efficiency in terms of limits of detection for which the interplay of the size and geometry of the sensor with the diffusion of the analytes plays a pivotal role.


Assuntos
Técnicas Biossensoriais/métodos , Íons/isolamento & purificação , Transistores Eletrônicos , Técnicas Biossensoriais/instrumentação , Concentração de Íons de Hidrogênio , Íons/química , Nanofios/química , Silício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...