Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 878(1): 45-55, 2000 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-10843544

RESUMO

By separating the first six linear and cyclic oligomers of polyamide-6 on a reversed-phase high-performance liquid chromatographic system after sandwich injection, quantitative determination of these oligomers becomes feasible. Low-wavelength UV detection of the different oligomers and selective post-column reaction detection of the linear oligomers with o-phthalic dicarboxaldehyde (OPA) and 3-mercaptopropionic acid (3-MPA) are discussed. A general methodology for quantification of oligomers in polymers was developed. It is demonstrated that the empirically determined group-equivalent absorption coefficients and quench factors are a convenient way of quantifying linear and cyclic oligomers of nylon-6. The overall long-term performance of the method was studied by monitoring a reference sample and the calibration factors of the linear and cyclic oligomers.


Assuntos
Caprolactama/análogos & derivados , Cromatografia Líquida de Alta Pressão/métodos , Polímeros/química , Caprolactama/química , Espectrofotometria Ultravioleta
2.
J Chromatogr A ; 876(1-2): 37-50, 2000 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-10823500

RESUMO

We report a method for reliable routine polymer sample introduction with minimal bias, a separation method of the first six linear and cyclic oligomers by liquid chromatography, quantification using group equivalents and long term method performance. Injecting a polymer sample in a mobile phase containing an aqueous non-solvent often results in blocked systems as the polymer precipitates in the connecting capillaries. In this first part we focus on a new injection technique, in which the dissolved polyamide is placed between two zones of formic acid, preventing the polymer to precipitate before it reaches the column. Development of this sandwich injection method makes direct injection of the polymer into an aqueous acetonitrile gradient feasible. The oligomeric polyamide recovery of this technique, extraction, dissolution/precipitation and direct injection on a hexafluoro-isopropanol (HFIP) gradient were compared. With the sandwich injection method the polymer remains on the column, slowly changing the stationary phase. The influence of this on resolution and retention was studied. Column stability allows sixty injections before cleaning or replacing the column is necessary.


Assuntos
Caprolactama/análogos & derivados , Cromatografia Líquida/métodos , Polímeros/química , Acetonitrilas/química , Caprolactama/química , Formiatos/química , Hidrocarbonetos Cíclicos/análise , Injeções , Politetrafluoretileno/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA