Radiology ; 306(2): e213198, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36165790

RESUMO

Background A new modality, phase-sensitive breast tomosynthesis (PBT), may have similar diagnostic performance to conventional breast tomosynthesis but with a reduced radiation dose. Purpose To perform a pilot study of the performance of a novel PBT system compared with conventional digital breast tomosynthesis (DBT) in patients undergoing additional diagnostic imaging workup for breast lesions. Materials and Methods In a prospective study from June 2020 to March 2021, participants with suspicious breast lesions detected at screening DBT or MRI were recruited for additional PBT imaging before additional diagnostic workup or biopsy. In this pilot study, nine radiologists independently evaluated image quality and assessed the likelihood of lesion malignancy by retrospectively evaluating DBT and PBT images in two separate reading sessions. Image quality was rated subjectively using a Likert scale from 1 to 5. Areas under the receiver operating characteristic curve (AUCs) were used to compare the lesion classification (malignant vs benign) performance of the radiologists. Results Images in 50 patients (mean age, 56 years ± 12 [SD]; 49 women) with 52 evaluable lesions (28 malignant) were assessed. For image appearance and general feature visibility, DBT images had a higher total mean image quality score (3.8) than PBT images (2.9), with P < .002 for each comparison. For classification of lesions as benign or malignant, the AUCs were 0.74 for both PBT and DBT. PBT images were acquired at a 24% mean radiation dose reduction (mean, 1.78 mGy vs 2.34 mGy for DBT; P < .001). Conclusion The phase-sensitive breast tomosynthesis system had a 24% lower mean radiation dose compared with digital breast tomosynthesis, although with lower image quality. Diagnostic performance of the system remains to be determined in larger studies. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Gao and Moy in this issue.


Assuntos
Neoplasias da Mama , Mama , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Mama/diagnóstico por imagem , Mamografia/métodos , Neoplasias da Mama/patologia
2.
J Xray Sci Technol ; 30(2): 207-219, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34957945

RESUMO

PURPOSE: To compare imaging performance of a cadmium telluride (CdTe) based photon counting detector (PCD) with a CMOS based energy integrating detector (EID) for potential phase sensitive imaging of breast cancer. METHODS: A high energy inline phase sensitive imaging prototype consisting of a microfocus X-ray source with geometric magnification of 2 was employed. The pixel pitch of the PCD was 55µm, while 50µm for EID. The spatial resolution was quantitatively and qualitatively assessed through modulation transfer function (MTF) and bar pattern images. The edge enhancement visibility was assessed by measuring edge enhancement index (EEI) using the acrylic edge acquired images. A contrast detail (CD) phantom was utilized to compare detectability of simulated tumors, while an American College of Radiology (ACR) accredited phantom for mammography was used to compare detection of simulated calcification clusters. A custom-built phantom was employed to compare detection of fibrous structures. The PCD images were acquired at equal, and 30% less mean glandular dose (MGD) levels as of EID images. Observer studies along with contrast to noise ratio (CNR) and signal to noise ratio (SNR) analyses were performed for comparison of two detection systems. RESULTS: MTF curves and bar pattern images revealed an improvement of about 40% in the cutoff resolution with the PCD. The excellent spatial resolution offered by PCD system complemented superior detection of the diffraction fringes at boundaries of the acrylic edge and resulted in an EEI value of 3.64 as compared to 1.44 produced with EID image. At equal MGD levels (standard dose), observer studies along with CNR and SNR analyses revealed a substantial improvement of PCD acquired images in detection of simulated tumors, calcification clusters, and fibrous structures. At 30% less MGD, PCD images preserved image quality to yield equivalent (slightly better) detection as compared to the standard dose EID images. CONCLUSION: CdTe-based PCDs are technically feasible to image breast abnormalities (low/high contrast structures) at low radiation dose levels using the high energy inline phase sensitive imaging technique.


Assuntos
Neoplasias da Mama , Compostos de Cádmio , Pontos Quânticos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imagens de Fantasmas , Fótons , Telúrio , Raios X
3.
Phys Med Biol ; 66(21)2021 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-34633295

RESUMO

Phase-sensitive x-ray imaging continues to attract research for its ability to visualize weakly absorbing details like those often encountered in biology and medicine. We have developed and assembled the first inline-based high-energy phase sensitive breast tomosynthesis (PBT) system, which is currently undergoing patient imaging testing at a clinical site. The PBT system consists of a microfocus polychromatic x-ray source and a direct conversion-based flat panel detector coated with a 1 mm thick amorphous selenium layer allowing a high detective quantum efficiency at high energies. The PBT system scans a compressed breast over 15° with 9 angular projection views. The high-energy scan parameters are carefully selected to ensure similar or lower mean glandular dose levels to the clinical standard of care systems. Phase retrieval and data binning are applied to the phase contrast angular projection views and a filtered back-projection algorithm is used to reconstruct the final images. This article reports the distributions of radiation dose versus thickness of the compressed breasts at 59 and 89 kV and sample PBT images acquired from 3 patients. Preliminary PBT images demonstrate the feasibility of this new imaging modality to acquire breast images at lower radiation dose as compared to the clinical digital breast tomosynthesis system with enhanced lesion characteristics (i.e. lesion spiculation and margins).


Assuntos
Neoplasias da Mama , Neoplasias , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Mamografia , Neoplasias/patologia , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Raios X
4.
J Appl Clin Med Phys ; 22(10): 320-328, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34469057

RESUMO

OBJECTIVE: The objective of this article is to introduce a simplified and swift method to satisfactorily estimate the half-value layers (HVL), quarter-value layer (QVL), and tenth-value layer (TVL) from the x-ray spectra emitted by any diagnostic radiology or kV radiotherapy x-ray tubes. METHODS: A CdTe x-ray and Gamma detector (X-123 CdTe, AmpTek Inc.) is used to measure the x-ray spectra at four different x-ray energies (low, mid, high energy x-rays) with different external filtering. The software "SpekCalc GUI" (Developed in McGill University, Montreal, Canada) is also used to obtain the simulated x-ray spectra. Both measured and simulated spectra are used to compute the HVL thicknesses of Aluminum by a mathematical method presented in this article. Next, the HVL thicknesses for corresponding tube potentials are also measured by calibrated ionization chamber and varying thicknesses of aluminum plates. Finally, the computed and measured HVL, QVL, and TVL thicknesses are compared to evaluate the efficacy of the presented method. RESULTS: The results show acceptable concordance between computed and measured quantities. The disagreement rates between measured HVL and the values derived mathematically from the x-ray spectra are 10 to 90 micrometers of Aluminum at tube potentials of 31 kV to 120 kV. As it is shown, a negligible discrepancy is observed between the analytical estimation and the experimental assessments. CONCLUSION: The HVL is an essential component in the evaluation of the quality of an x-ray beam. However, its measurement could occasionally be challenging, time-consuming, or uncertain due to some technical difficulties. Although the scope of this study is not to undermine the value of conventional and widely accepted practice to determine the HVL thickness, the introduced method provides the fast, more convenient, and comparably reliable technique to estimate the HVL, QVL, and TVL by employing the given x-ray spectrum.


Assuntos
Compostos de Cádmio , Pontos Quânticos , Humanos , Telúrio , Raios X
5.
Med Phys ; 48(5): 2511-2520, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33523479

RESUMO

BACKGROUND: This article reports the first x-ray phase sensitive breast tomosynthesis (PBT) system that is aimed for direct translation to clinical practice for the diagnosis of breast cancer. PURPOSE: To report the preclinical evaluation and comparison of the newly built PBT system with a conventional digital breast tomosynthesis (DBT) system. METHODS AND MATERIALS: The PBT system is developed based on a comprehensive inline phase contrast theoretical model. The system consists of a polyenergetic microfocus x-ray source and a flat panel detector mounted on an arm that is attached to a rotating gantry. It acquires nine projections over a 15° angular span in a stop-and-shoot manner. A dedicated phase retrieval algorithm is integrated with a filtered back-projection method that reconstructs tomographic slices. The American College of Radiology (ACR) accreditation phantom, a contrast detail (CD) phantom and mastectomy tissue samples were imaged at the same glandular dose levels by both the PBT and a standard of care DBT system for image quality characterizations and comparisons. RESULTS: The PBT imaging scores with the ACR phantom are in good to excellent range and meet the quality assurance criteria set by the Mammography Quality Standard Act. The CD phantom image comparison and associated statistical analyses from two-alternative forced-choice reader studies confirm the improvement offered by the PBT system in terms of contrast resolution, spatial resolution, and conspicuity. The artifact spread function (ASF) analyses revealed a sizable lateral spread of metal artifacts in PBT slices as compared to DBT slices. Signal-to-noise ratio values for various inserts of the ACR and CD phantoms further validated the superiority of the PBT system. Mastectomy sample images acquired by the PBT system showed a superior depiction of microcalcifications vs the DBT system. CONCLUSION: The PBT imaging technology can be clinically employed for improving the accuracy of breast cancer screening and diagnosis.


Assuntos
Neoplasias da Mama , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Humanos , Mamografia , Mastectomia , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Raios X
6.
Biomed Spectrosc Imaging ; 8(1-2): 29-40, 2019 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-31788419

RESUMO

A single-projection based phase retrieval method based on the phase attenuation duality principle (PAD) was used to compare the spatial resolution of the acquired phase sensitive and PAD processed phase retrieved images. An inline phase sensitive prototype was used to acquire the phase sensitive images. The prototype incorporates a micro-focus x-ray source and a flat panel detector with a 50 µm pixel pitch. A phantom composed of a 2 cm thick 50-50 adipose-glandular mimicking slab sandwiched with a 0.82 cm thick slanted PMMA sharp edge was used. Phase sensitive image of the phantom was acquired at 120 kV, 3.35 mAs with a 16 µm tube focal spot size under a geometric magnification (M) of 2.5. The PAD based method was applied to the acquired phase sensitive image for the retrieval of phase values. With necessary data processing, modulation transfer function (MTF) curves were determined for the estimation and comparison of the spatial resolution. The PAD processed phase retrieved values of the phantom were in good agreement with the theoretically calculated values. Phase sensitive images showed higher spatial resolution at all spatial frequencies compared to the phase retrieved images. It was noted that the high-frequency signal components in the retrieved image were suppressed that resulted in lower MTF values. When compared to the phase sensitive image, the cutoff resolution (10% MTF) for phase retrieved image dropped 32% from 15.6 lp/mm (32µm) to 10.6 lp/mm (47µm). The resolution offered by this phase sensitive prototype is radiographically enough to detect breast cancer.

7.
Phys Med ; 47: 34-41, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29609816

RESUMO

This study compared the detectability of simulated tumors using a high-energy X-ray inline phase sensitive digital breast tomosynthesis (DBT) prototype and a commercial attenuation-based DBT system. Each system imaged a 5-cm thick modular breast phantom with 50-50 adipose-glandular percentage density containing contrast-detail (CD) test objects to simulate different tumor sizes. A commercial DBT system acquired 15 projection views over 15 degrees (15d-15p) was used to acquire the attenuation-based projection views and to reconstruct the conventional DBT slices. Attenuation-based projection views were acquired at 32 kV, 46 mAs with a mean glandular dose (Dg) of 1.6 mGy. For acquiring phase sensitive projection views, the prototype utilized two acquisition geometries: 11 projection views were acquired over 15 degrees (15d-11p), and 17 projection views were acquired over 16 degrees (16d-17p) at 120 kV, 5.27 mAs with 1.51 mGy under the magnification (M) of 2. A phase retrieval algorithm based on the phase-attenuation duality (PAD) was applied to each projection view, and a modified Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct the phase sensitive DBT slices. Simulated tumor margins were rated as more conspicuous and better visualized for both phase sensitive acquisition geometries versus conventional DBT imaging. The CD curves confirmed the improvement in both contrast and spatial resolutions with the phase sensitive DBT imaging. The superiority of the phase sensitive DBT imaging was further endorsed by higher contrast to noise ratio (CNR) and figure-of-merit (FOM) values. The CNR improvements provided by the phase sensitive DBT prototype were sufficient to offset the noise reduction provided by the attenuation-based DBT imaging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Imagens de Fantasmas , Algoritmos , Neoplasias da Mama/patologia , Razão Sinal-Ruído , Carga Tumoral , Raios X