1.
Muscle Nerve ; 44(1): 45-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21674520

RESUMO

INTRODUCTION: Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. METHODS: Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. RESULTS: Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory.


Assuntos
Eletromiografia/instrumentação , Eletromiografia/normas , Músculo Esquelético/diagnóstico por imagem , Agulhas/normas , Cadáver , Humanos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Ultrassonografia/normas