Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bull Hosp Jt Dis (2013) ; 74(4): 249-253, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27815946

RESUMO

Gradual distal fibula lengthening (DFL), in conjunction with other procedures, was used to correct ankle valgus and short fibulae in three pediatric patients with multiple hereditary exostoses (MHE). The average amount of DFL was 15 mm with a mean follow-up of 2.9 years. Final radiographs showed that all three patients had a stable ankle mortise without evidence of talar tilt or widening. In conclusion, gradual DFL has the advantage of restoring anatomy in cases of ankle valgus due to short fibulae and MHE, and may be performed in conjunction with other procedures.


Assuntos
Articulação do Tornozelo/cirurgia , Exostose Múltipla Hereditária/cirurgia , Fíbula/cirurgia , Deformidades Adquiridas do Pé/cirurgia , Osteogênese por Distração , Tíbia/cirurgia , Adolescente , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiopatologia , Fenômenos Biomecânicos , Remodelação Óssea , Parafusos Ósseos , Criança , Exostose Múltipla Hereditária/diagnóstico por imagem , Exostose Múltipla Hereditária/fisiopatologia , Fíbula/diagnóstico por imagem , Fíbula/fisiopatologia , Deformidades Adquiridas do Pé/diagnóstico , Deformidades Adquiridas do Pé/fisiopatologia , Humanos , Masculino , Osteogênese por Distração/instrumentação , Recuperação de Função Fisiológica , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
2.
Bull Hosp Jt Dis (2013) ; 73(2): 109-15, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26517163

RESUMO

Osseous injuries affecting the posterosuperolateral aspect of the humeral head, also known as the Hill-Sachs lesion, are common and can pose a difficult problem for the operating surgeon. Hill-Sachs lesions can lead to recurrent shoulder instability if not identified and addressed. This review will focus on osseous defects of the humeral head and address the pathoanatomy, diagnosis, indications, and surgical techniques for the treatment of these lesions.


Assuntos
Cabeça do Úmero , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Fenômenos Biomecânicos , História do Século XX , História do Século XXI , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/fisiopatologia , Cabeça do Úmero/cirurgia , Instabilidade Articular/diagnóstico , Instabilidade Articular/história , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Procedimentos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Radiografia , Amplitude de Movimento Articular , Recidiva , Luxação do Ombro/diagnóstico , Luxação do Ombro/história , Luxação do Ombro/fisiopatologia , Luxação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Resultado do Tratamento
3.
Bull Hosp Jt Dis (2013) ; 72(3): 231-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25429392

RESUMO

BACKGROUND: The purpose of this study was to examine functional outcomes following ORIF of displaced proximal humerus fractures in patients who received brachial plexus blocks compared to those who underwent general anesthesia. METHODS: We retrospectively reviewed prospectively collected data on 92 patients. Patients were grouped according to anesthesia type: regional interscalene brachial plexus block, with or without general anesthesia, or general anesthesia alone. Patients were asked to complete the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and range of motion assessments at a minimum of 6-month follow-up. Plain radiographic films were obtained to assess fracture healing. RESULTS: Forty-five (48.9%) patients with 45 proximal humerus fractures received a regional anesthetic, while 47 (51.1%) patients with 48 proximal humerus fractures had general anesthesia. No significant differences existed in demographic information or fracture type. DASH scores at the most recent follow-up were significantly better in the regional block group (38.6) compared to the general anesthesia group (53.1) (p = 0.003). The regional block group had significantly better passive and active forward elevation and external rotation range and equivalent internal rotation (p = 0.002, 0.005, 0.002, and 0.507, respectively). CONCLUSION: Patients who received regional anesthetic via a brachial plexus interscalene blocks had better functional outcomes and range of motion at the most recent clinical follow-up. Regional anesthesia provides patients with prolonged postoperative pain relief, which may allow for early mobilization, increasing the likelihood that the patient's function and range of motion will return to baseline.


Assuntos
Anestesia Geral/métodos , Bloqueio do Plexo Braquial/métodos , Dor Pós-Operatória/prevenção & controle , Fraturas do Ombro , Articulação do Ombro , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/reabilitação , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Fraturas do Ombro/diagnóstico , Fraturas do Ombro/cirurgia , Lesões do Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Resultado do Tratamento
4.
Instr Course Lect ; 63: 465-72, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24720331

RESUMO

The unsustainable rising cost of medical care is creating financial pressures that will critically alter the way that health care is paid for and delivered. Limited resources dictate that physicians must become more efficient at providing high quality care. In an effort to provide financial incentive for delivering quality care, the federal government instituted value-based purchasing to transform Medicare from a passive payer of claims to an active purchaser of medical care. Healthcare providers must follow the basic tenants of certain quality principles to maximize reimbursement under the value-based purchasing system.


Assuntos
Medicare/economia , Ortopedia/organização & administração , Patient Protection and Affordable Care Act , Qualidade da Assistência à Saúde/organização & administração , Hospitalização , Humanos , Estados Unidos , Aquisição Baseada em Valor
5.
Geriatr Orthop Surg Rehabil ; 4(1): 21-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23936736

RESUMO

PURPOSE: To investigate the effects of age on the clinical, functional, and radiographic outcomes of patients with proximal humerus fractures treated operatively with locking plates. METHODS: Between February 2003 and July 2012, all patients who sustained a proximal humerus fracture who presented to our institution were enrolled into a database. Patients were followed up at 1, 6, 12, 26, and 52 weeks postoperatively with physical examination and radiographs. Validated functional outcomes scores were collected at 6 and 12 months. Complications were recorded as they occurred. Statistical analysis was conducted to assess for functional, physical, or radiographic differences between patients age younger than 65 and patients age 65 or older. RESULTS: Of the 147 consecutive patients treated operatively for a proximal humerus fracture, 115 (78%) patients with an average follow-up of 16 months met the inclusion criteria for this study. The young cohort (patients < 65) included 70 patients with an average age of 53, whereas the elderly cohort (patients ≥ 65) included 45 patients with an average age of 73. The older cohort had significantly more women (P = .04), but there was no statistical difference in fracture type between the age groups. There were no differences in the radiographic measures of screw penetration, humeral head height, and neck-shaft angle between the age groups. There were no differences in physical examination scores between the age groups. There were no significant differences in functional outcomes or complication rates between the age groups. CONCLUSION: Treating proximal humerus fractures operatively with locked plates can overcome the challenges of poor bone quality that often occur with increasing age. Age should not play a significant role in the decision-making process for treating proximal humerus fractures that would otherwise be indicated for surgical fixation.

6.
Clin Orthop Relat Res ; 471(4): 1277-82, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23054520

RESUMO

BACKGROUND: The incidence of heterotopic ossification (HO) after hip arthroscopy reportedly ranges from less than 1.0% to 6.3%. Although open debridement has been described and a few series mention arthroscopic debridement, the techniques for arthroscopic excision of HO have not been described in detail. We describe the arthroscopic treatment of this complication. DESCRIPTION OF TECHNIQUE: Revision arthroscopy was completed in the central and peripheral compartments using prior portals and fluoroscopy was used to identify the HO. Spinal needle localization was used to triangulate onto the HO. Cannulas were inserted over the spinal needle. Once the HO was clearly identified with the arthroscope, it was excised using a burr and confirmed on fluoroscopy. METHODS: We retrospectively reviewed 66 patients who underwent arthroscopic treatment of femoroacetabular impingement between July 2008 and June 2010. There were 36 females and 30 males with an average age of 38 years (range, 15-68 years). Eight of the 66 (12%) patients had HO develop. Using the grading of Brooker et al., six patients had Grade 1, one had Grade 2, and one had Grade 3 HO. Three patients with HO were symptomatic and underwent arthroscopic resection. We obtained modified Harris hip scores (HHS) and radiographs at followup. The minimum followup for the three patients with revision surgery was 2 years (mean, 2 years 2 months; range, 2 years-2 years 8 months). RESULTS: The three patients who underwent arthroscopic resection had HHS ranging from 85 to 96 at last followup. No patient had recurrence of HO. CONCLUSIONS: Our data suggest HO is not uncommon after hip arthroscopy for the treatment of femoroacetabular impingement but most patients have minor degrees and no symptoms. In symptomatic patients, arthroscopic excision appears to relieve pain and restore function.


Assuntos
Artroscopia/métodos , Impacto Femoroacetabular/cirurgia , Ossificação Heterotópica/etiologia , Ossificação Heterotópica/cirurgia , Complicações Pós-Operatórias/cirurgia , Adolescente , Adulto , Idoso , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
7.
Bull NYU Hosp Jt Dis ; 70(4): 241-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23267448

RESUMO

PURPOSE: Accurate prediction of autograft size for anterior cruciate ligament reconstruction can assist in preoperative planning and decision-making regarding graft choices. This study seeks to determine the accuracy of MRI measurements by comparing intraoperative measurements of the patella, semitendinosis, and gracilis tendons while correlating these measurements with patient anthropometric data such as gender, height, and weight. METHODS: A series of 20 consecutive patients were enrolled who underwent a magnetic resonance imaging study of the knee and proceeded with surgical reconstruction of the anterior cruciate ligament. Intraoperative measurements of the diameter of semitendinosis and gracilis tendons or width of patella tendon were compared to radiographic measurements obtained on the MRI. These measurements were analyzed using a paired t-test as well as regression analysis to evaluate strength of correlation between measurements and also to determine correlation with height, weight, and gender. RESULTS: There was no statistical difference between intraoperative and radiographic measurements (p > 0.05). There was strong correlation (Pearson r = 0.98, p = 0.00) found between intraoperative and radiographic measurements of the autograft tendons. Weaker correlation was seen with gender, height, and weight with intraoperative measurements. CONCLUSIONS: Measuring the diameter of the semitendinosis and gracilis tendons and patellar width on MRI can give an accurate prediction of actual intraoperative sizes of these anatomic structures. Height, weight, and gender were also correlated with tendon sizes implying that a patient of female gender or of smaller stature in height or weight may have smaller tendon sizes. Routine use of preoperative MRI measurements can guide surgeons with specific graft preferences to other surgical options if the graft is measured to be insufficient in size.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Imageamento por Ressonância Magnética , Ligamento Patelar/transplante , Adulto , Ligamento Cruzado Anterior/patologia , Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Estatura , Peso Corporal , Transplante Ósseo , Feminino , Humanos , Modelos Lineares , Masculino , Ligamento Patelar/anatomia & histologia , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Estudos Retrospectivos , Fatores Sexuais , Coleta de Tecidos e Órgãos , Transplante Autólogo , Adulto Jovem
8.
Am J Orthop (Belle Mead NJ) ; 41(9): 407-12, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23365808

RESUMO

We conducted a study to evaluate the outcomes and complications of open reduction and internal fixation (ORIF) of 2-, 3-, and 4-part proximal humerus fractures using a standard management protocol with locking plates. Of 72 patients with acute proximal humerus fractures managed with ORIF and locking plates, 63 were available at the minimum follow-up of 1 year and met the inclusion criteria. At each follow-up, radiographs were reviewed for healing, hardware failure, osteonecrosis, shoulder range of motion, and DASH (Disabilities of the Arm, Shoulder, and Hand) scores; any complications were recorded. Mean age was 62 years and mean follow-up was 19 months. There were 12 two-part fractures, 42 three-part fractures, and 9 four-part fractures. Thirteen patients had complications. Mean shoulder forward elevation was 135; patients with complications had a significantly lower mean forward elevation (P=.002). DASH scores were significantly lower in patients without complications than in those with complications (P=.01). Although excellent outcomes can be achieved when locking plates are used to manage proximal humerus fractures, complications are possible. Physicians must weigh the functional outcome data when considering management options for these types of injuries.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas do Ombro/cirurgia , Feminino , Fixação Interna de Fraturas/efeitos adversos , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Fraturas do Ombro/diagnóstico por imagem , Resultado do Tratamento
9.
J Shoulder Elbow Surg ; 21(6): 741-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22192764

RESUMO

BACKGROUND: We sought to examine fracture settling and screw penetration after open reduction-internal fixation of 2-, 3-, and 4-part proximal humeral fractures and determine whether the use of calcium phosphate cement reduced these unwanted complications. METHODS: We performed a retrospective study of prospective data. Inclusion criteria included patient age of 18 years or older and an acute traumatic fracture of the proximal humerus that was treated with open reduction-internal fixation with a locked plate. Metaphyseal defects were treated with 1 of 3 strategies: no augmentation, augmentation with cancellous chips, or augmentation with calcium phosphate cement. Various radiographic measurements were made at each follow-up visit to assess for humeral head settling or collapse. Overall, 92 patients (81%) met the inclusion criteria and form the basis of this study. Augmentation type included 29 patients (32%) with cancellous chips, 27 (29%) with calcium phosphate cement, and 36 (39%) with no augmentation. RESULTS: There were no statistical differences among the groups with respect to patient age, sex, and fracture type. At the 3, 6, and 12-month follow-up visits, there was less humeral head settling with calcium phosphate cement compared with repair with no augmentation or with cancellous chips. Findings of joint penetration were significant among patients treated with plates and screws alone versus those augmented with calcium phosphate (P = .02) and for those augmented with cancellous chips versus those augmented with calcium phosphate (P = .009). CONCLUSION: Augmentation with calcium phosphate cement in the treatment of proximal humeral fractures with locked plates decreased fracture settling and significantly decreased intra-articular screw penetration.


Assuntos
Cimentos Ósseos/uso terapêutico , Parafusos Ósseos , Fosfatos de Cálcio/uso terapêutico , Fraturas do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos
10.
Clin Orthop Relat Res ; 469(12): 3292-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21416205

RESUMO

BACKGROUND: Locking plates have become a commonly used fixation device in the operative treatment of three- and four-part proximal humerus fractures. Examining function in patients treated nonoperatively and operatively should help determine whether and when surgery is appropriate in these difficult-to-treat fractures. QUESTIONS/PURPOSES: We compared functional scores, ROM, and radiographs in patients with one-part proximal humerus fractures treated nonoperatively to those in patients with displaced three- and four-part proximal humerus fractures treated with open reduction and internal fixation using locking plates. PATIENTS AND METHODS: We retrospectively reviewed 142 patients with proximal humerus fractures treated with a standardized treatment algorithm over a 6-year period. Three- and four-part fractures were treated surgically while one-part fractures were treated nonoperatively. Functional scores, ROM, and radiographs were used to evaluate outcomes. American Shoulder and Elbow Surgeons and SF-36 scores were obtained at 12 months. Of the 142 patients, 101 (51 with three- or four-part fractures and 50 with one-part fractures) had a minimum followup of 12 months (average, 19 months; range, 12-64 months). RESULTS: The fractures united in all patients. At 1 year, the patients with one-part fractures had better SF-36 physical and mental scores and American Shoulder and Elbow Surgeons scores than the three- and four-part fractures. Both groups had similar shoulder ROM. Nine patients treated operatively had complications, four of which were related to screw penetration into the joint. CONCLUSIONS: Patients with three- and four-part fractures should be advised of the likelihood of persistent functional impairment and a relatively higher risk of complications when treated operatively with locked plates. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Fixação Interna de Fraturas , Recuperação de Função Fisiológica , Fraturas do Ombro/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Fixação Interna de Fraturas/efeitos adversos , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Resultado do Tratamento
11.
J Orthop Trauma ; 22(3): 159-64, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18317048

RESUMO

PURPOSE: To examine our incidence of early complications that occur using the Proximal Humeral Internal Locking System (PHILOS) and to determine the contributing factors. SETTING: Academic medical center. PATIENTS: Fifty-one consecutive patients treated with a proximal humerus locking plate. OUTCOME: Development of an intraoperative, acute postoperative, or delayed postoperative complication. METHODS: A retrospective analysis was undertaken of a consecutive series of proximal humerus fractures treated with a locking plate between February 2003 and January 2006 at our institution. Fifty-one fractures or fracture nonunions were identified in 18 male and 33 female patients with an average age of 61. All acute injuries were treated with a similar protocol of open reduction internal fixation with the PHILOS plate followed by early range of shoulder motion. Nonunions were treated in a similar manner with the addition of iliac crest bone graft placement. Patients were objectively assessed on their outcome by physical as well as radiological examination. All complications were recorded. Statistical analyses were performed to determine if patient age, fracture type, or number of screws placed in the humeral head contributed to complications. RESULTS: Fifty-one patients were available for minimum 6-month follow-up (mean, 16 months; range, 6 to 45 months). Radiographically, 92% of the cases united at 3 months after surgery, and 2 fractures had signs of osteonecrosis at latest follow-up. Sixteen complications were seen in 12 patients (24%). Eight shoulders in eight patients (16%) had screws that penetrated the humeral head. Two patients developed osteonecrosis at latest follow-up. One acute fracture and one nonunion failed to unite after index surgery. Significant heterotopic bone developed in 1 patient. Early implant failure occurred in 2 patients; one was revised to a longer plate, and one underwent resection arthroplasty. There was one acute postoperative infection. CONCLUSION: The major complication reported in this study was screw penetration, suggesting that exceptional vigilance must be taken in estimating the appropriate number and length of screws used to prevent articular penetration; although the device provides exceptional fixation stability, its indication must be scrutinized for each individual patient, taking the extent of trauma/fracture and age into consideration and carefully weighing it against other forms of treatment.


Assuntos
Placas Ósseas/efeitos adversos , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Úmero/cirurgia , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Feminino , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...