Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Sci Rep ; 11(1): 6814, 2021 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-33767303

RESUMO

Hepatic radiofrequency ablation (RFA) induces a drastic alteration of the biomechanical environment in the peritumoral liver tissue. The resulting increase in matrix stiffness has been shown to significantly influence carcinogenesis and cancer progression after focal RF ablation. To investigate the potential of an elastin-specific MR agent (ESMA) for the assessment of extracellular matrix (ECM) remodeling in the periablational rim following RFA in a VX2 rabbit liver tumor-model, twelve New-Zealand-White-rabbits were implanted in the left liver lobe with VX2 tumor chunks from donor animals. RFA of tumors was performed using a perfused RF needle-applicator with a mean tip temperature of 70 °C. Animals were randomized into four groups for MR imaging and scanned at four different time points following RFA (week 0 [baseline], week 1, week 2 and week 3 after RFA), followed by sacrifice and histopathological analysis. ESMA-enhanced MR imaging was used to assess ECM remodeling. Gadobutrol was used as a third-space control agent. Molecular MR imaging using an elastin-specific probe demonstrated a progressive increase in contrast-to-noise ratio (CNR) (week 3: ESMA: 28.1 ± 6.0; gadobutrol: 3.5 ± 2.0), enabling non-invasive imaging of the peritumoral zone with high spatial-resolution, and accurate assessment of elastin deposition in the periablational rim. In vivo CNR correlated with ex vivo histomorphometry (ElasticaVanGiesson-stain, y = 1.2x - 1.8, R2 = 0.89, p < 0.05) and gadolinium concentrations at inductively coupled mass spectroscopy (ICP-MS, y = 0.04x + 1.2, R2 = 0.95, p < 0.05). Laser-ICP-MS confirmed colocalization of elastin-specific probe with elastic fibers. Following thermal ablation, molecular imaging using an elastin-specific MR probe is feasible and provides a quantifiable biomarker for the assessment of the ablation-induced remodeling of the ECM in the periablational rim.


Assuntos
Elastina/metabolismo , Matriz Extracelular/metabolismo , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/metabolismo , Imageamento por Ressonância Magnética , Animais , Ablação por Cateter/métodos , Modelos Animais de Doenças , Feminino , Gadolínio , Humanos , Neoplasias Hepáticas/terapia , Masculino , Espectrometria de Massas , Imagem Molecular/métodos , Cuidados Pós-Operatórios , Coelhos , Ablação por Radiofrequência/métodos
2.
Sci Rep ; 9(1): 13827, 2019 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-31554825

RESUMO

Molecular MRI is a promising in-vivo modality to detect and quantify morphological and molecular vessel-wall changes in atherosclerosis. The combination of different molecular biomarkers may improve the risk stratification of patients. This study aimed to investigate the feasibility of simultaneous visualization and quantification of plaque-burden and inflammatory activity by dual-probe molecular MRI in a mouse-model of progressive atherosclerosis and in response-to-therapy. Homozygous apolipoprotein E knockout mice (ApoE-/-) were fed a high-fat-diet (HFD) for up to four-months prior to MRI of the brachiocephalic-artery. To assess response-to-therapy, a statin was administered for the same duration. MR imaging was performed before and after administration of an elastin-specific gadolinium-based and a macrophage-specific iron-oxide-based probe. Following in-vivo MRI, samples were analyzed using histology, immunohistochemistry, inductively-coupled-mass-spectrometry and laser-inductively-coupled-mass-spectrometry. In atherosclerotic-plaques, intraplaque expression of elastic-fibers and inflammatory activity were not directly linked. While the elastin-specific probe demonstrated the highest accumulation in advanced atherosclerotic-plaques after four-months of HFD, the iron-oxide-based probe showed highest accumulation in early atherosclerotic-plaques after two-months of HFD. In-vivo measurements for the elastin and iron-oxide-probe were in good agreement with ex-vivo histopathology (Elastica-van-Giesson stain: y = 298.2 + 5.8, R2 = 0.83, p < 0.05; Perls' Prussian-blue-stain: y = 834.1 + 0.67, R2 = 0.88, p < 0.05). Contrast-to-noise-ratio (CNR) measurements of the elastin probe were in good agreement with ICP-MS (y = 0.11x-11.3, R² = 0.73, p < 0.05). Late stage atherosclerotic-plaques displayed the strongest increase in both CNR and gadolinium concentration (p < 0.05). The gadolinium probe did not affect the visualization of the iron-oxide-probe and vice versa. This study demonstrates the feasibility of simultaneous assessment of plaque-burden and inflammatory activity by dual-probe molecular MRI of progressive atherosclerosis. The in-vivo detection and quantification of different MR biomarkers in a single scan could be useful to improve characterization of atherosclerotic-lesions.


Assuntos
Óxido Ferroso-Férrico/administração & dosagem , Gadolínio/administração & dosagem , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/tratamento farmacológico , Pravastatina/administração & dosagem , Animais , Meios de Contraste , Dieta Hiperlipídica/efeitos adversos , Modelos Animais de Doenças , Elastina/metabolismo , Estudos de Viabilidade , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Camundongos , Camundongos Knockout para ApoE , Óxido Nítrico/metabolismo , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/metabolismo , Pravastatina/uso terapêutico , Sensibilidade e Especificidade
3.
Sci Transl Med ; 11(486)2019 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-30944168

RESUMO

Fibrosis is the common endpoint and currently the best predictor of progression of chronic kidney diseases (CKDs). Despite several drawbacks, biopsies remain the only available means to specifically assess the extent of renal fibrosis. Here, we show that molecular imaging of the extracellular matrix protein elastin allows for noninvasive staging and longitudinal monitoring of renal fibrosis. Elastin was hardly expressed in healthy mouse, rat, and human kidneys, whereas it was highly up-regulated in cortical, medullar, and perivascular regions in progressive CKD. Compared to a clinically relevant control contrast agent, the elastin-specific magnetic resonance imaging agent ESMA specifically detected elastin expression in multiple mouse models of renal fibrosis and also in fibrotic human kidneys. Elastin imaging allowed for repetitive and reproducible assessment of renal fibrosis, and it enabled longitudinal monitoring of therapeutic interventions, accurately capturing anti-fibrotic therapy effects. Last, in a model of reversible renal injury, elastin imaging detected ensuing fibrosis not identifiable via routine assessment of kidney function. Elastin imaging thus has the potential to become a noninvasive, specific imaging method to assess renal fibrosis.


Assuntos
Elastina/metabolismo , Rim/patologia , Imagem Molecular , Adulto , Idoso , Animais , Progressão da Doença , Elastina/ultraestrutura , Feminino , Fibrose , Humanos , Rim/diagnóstico por imagem , Rim/ultraestrutura , Nefropatias/patologia , Imageamento por Ressonância Magnética , Masculino , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Ratos Wistar
4.
Circ Cardiovasc Imaging ; 12(3): e008707, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30871334

RESUMO

BACKGROUND: Molecular magnetic resonance imaging is a promising modality for the characterization of abdominal aortic aneurysms (AAAs). The combination of different molecular imaging biomarkers may improve the assessment of the risk of rupture. This study investigates the feasibility of imaging inflammatory activity and extracellular matrix degradation by concurrent dual-probe molecular magnetic resonance imaging in an AAA mouse model. METHODS: Osmotic minipumps with a continuous infusion of Ang II (angiotensin II; 1000 ng/[kg·min]) to induce AAAs were implanted in apolipoprotein-deficient mice (N=58). Animals were assigned to 2 groups. In group 1 (longitudinal group, n=13), imaging was performed once after 1 week with a clinical dose of a macrophage-specific iron oxide-based probe (ferumoxytol, 4 mgFe/kg, surrogate marker for inflammatory activity) and an elastin-specific gadolinium-based probe (0.2 mmol/kg, surrogate marker for extracellular matrix degradation). Animals were then monitored with death as end point. In group 2 (week-by-week-group), imaging with both probes was performed after 1, 2, 3, and 4 weeks (n=9 per group). Both probes were evaluated in 1 magnetic resonance session. RESULTS: The combined assessment of inflammatory activity and extracellular matrix degradation was the strongest predictor of AAA rupture (sensitivity 100%; specificity 89%; area under the curve, 0.99). Information from each single probe alone resulted in lower predictive accuracy. In vivo measurements for the elastin- and iron oxide-probe were in good agreement with ex vivo histopathology (Prussian blue-stain: R2=0.96, P<0.001; Elastica van Giesson stain: R2=0.79, P<0.001). Contrast-to-noise ratio measurements for the iron oxide and elastin-probe were in good agreement with inductively coupled mass spectroscopy ( R2=0.88, R2=0.75, P<0.001) and laser ablation coupled to inductively coupled plasma-mass spectrometry. CONCLUSIONS: This study demonstrates the potential of the concurrent assessment of inflammatory activity and extracellular matrix degradation by dual-probe molecular magnetic resonance imaging in an AAA mouse model. Based on the combined information from both molecular probes, the rupture of AAAs could reliably be predicted.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Elastina/metabolismo , Matriz Extracelular/metabolismo , Óxido Ferroso-Férrico/administração & dosagem , Gadolínio DTPA/administração & dosagem , Mediadores da Inflamação/metabolismo , Imageamento por Ressonância Magnética , Imagem Molecular/métodos , Angiotensina II , Animais , Aorta Abdominal/metabolismo , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/induzido quimicamente , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/patologia , Ruptura Aórtica/induzido quimicamente , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/metabolismo , Ruptura Aórtica/patologia , Modelos Animais de Doenças , Progressão da Doença , Matriz Extracelular/patologia , Estudos de Viabilidade , Gadolínio DTPA/análogos & derivados , Masculino , Camundongos Knockout para ApoE , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo
5.
Contrast Media Mol Imaging ; 2018: 9217456, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30425609

RESUMO

Objectives: The aim of this study was to test the potential of a new elastin-specific molecular agent for the performance of contrast-enhanced first-pass and 3D magnetic resonance angiography (MRA), compared to a clinically used extravascular contrast agent (gadobutrol) and based on clinical MR sequences. Materials and Methods: Eight C57BL/6J mice (BL6, male, aged 10 weeks) underwent a contrast-enhanced first-pass and 3D MR angiography (MRA) of the aorta and its main branches. All examinations were on a clinical 3 Tesla MR system (Siemens Healthcare, Erlangen, Germany). The clinical dose of 0.1 mmol/kg was administered in both probes. First, a time-resolved MRA (TWIST) was acquired during the first-pass to assess the arrival and washout of the contrast agent bolus. Subsequently, a high-resolution 3D MRA sequence (3D T1 FLASH) was acquired. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for all sequences. Results: The elastin-specific MR probe and the extravascular imaging agent (gadobutrol) enable high-quality MR angiograms in all animals. During the first-pass, the probes demonstrated a comparable peak enhancement (300.6 ± 32.9 vs. 288.5 ± 33.1, p > 0.05). Following the bolus phase, both agents showed a comparable intravascular enhancement (SNR: 106.7 ± 11 vs. 102.3 ± 5.3; CNR 64.5 ± 7.4 vs. 61.1 ± 7.2, p > 0.05). Both agents resulted in a high image quality with no statistical difference (p > 0.05). Conclusion: The novel elastin-specific molecular probe enables the performance of first-pass and late 3D MR angiography with an intravascular contrast enhancement and image quality comparable to a clinically used extravascular contrast agent.


Assuntos
Aorta , Meios de Contraste/farmacologia , Elastina/metabolismo , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Sondas Moleculares/farmacologia , Animais , Aorta/diagnóstico por imagem , Aorta/metabolismo , Meios de Contraste/química , Masculino , Camundongos , Sondas Moleculares/química
6.
Circ Cardiovasc Imaging ; 7(4): 679-89, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24871347

RESUMO

BACKGROUND: The incidence of abdominal aortic aneurysms (AAAs) has increased during the last decades. However, there is still controversy about the management of medium-sized AAAs. Therefore, novel biomarkers, besides aneurysmal diameter, are needed to assess aortic wall integrity and risk of rupture. Elastin is the key protein for maintaining aortic wall tensile strength and stability. The progressive breakdown of structural proteins, in particular, medial elastin, is responsible for the inability of the aortic wall to withstand intraluminal hemodynamic forces. Here, we evaluate the usefulness of elastin-specific molecular MRI for the in vivo characterization of AAAs. METHODS AND RESULTS: To induce AAAs, ApoE(-/-) mice were infused with angiotensin-II. An elastin-specific magnetic resonance molecular imaging agent (ESMA) was administered after 1, 2, 3, and 4 weeks of angiotensin-II infusion to assess elastin composition of the aorta (n=8 per group). The high signal provided by ESMA allowed for imaging with high spatial resolution, resulting in an accurate assessment of ruptured elastic laminae and the compensatory expression of elastic fibers. In vivo contrast-to-noise ratios and R1-relaxation rates after ESMA administration were in good agreement with ex vivo histomorphometry (Elastica van Gieson stain) and gadolinium concentrations determined by inductively coupled plasma mass spectroscopy. Electron microscopy confirmed colocalization of ESMA with elastic fibers. CONCLUSIONS: Changes in elastin content could be readily delineated and quantified at different stages of AAAs by elastin-specific molecular magnetic resonance imaging. ESMA-MRI offers potential for the noninvasive detection of the aortic rupture site prior to dilation of the aorta and the subsequent in vivo monitoring of compensatory repair processes during the progression of AAAs.


Assuntos
Aorta Abdominal/química , Aneurisma da Aorta Abdominal/diagnóstico , Elastina/análise , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Animais , Aorta Abdominal/fisiopatologia , Aorta Abdominal/ultraestrutura , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Animais de Doenças , Elasticidade , Masculino , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica
7.
Circ Cardiovasc Imaging ; 7(4): 690-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24814820

RESUMO

BACKGROUND: Ascending aortic dissection and rupture remain a life-threatening complication in patients with Marfan syndrome. The extracellular matrix provides strength and elastic recoil to the aortic wall, thereby preventing radial expansion. We have previously shown that ascending aortic aneurysm formation in Marfan mice (Fbn1(C1039G/+)) is associated with decreased aortic wall elastogenesis and increased elastin breakdown. In this study, we test the feasibility of quantifying aortic wall elastin content using MRI with a gadolinium-based elastin-specific magnetic resonance contrast agent in Fbn1(C1039G/+) mice. METHODS AND RESULTS: Ascending aorta elastin content was measured in 32-week-old Fbn1(C1039G/+) mice and wild-type (n=9 and n=10, respectively) using 7-T MRI with a T1 mapping sequence. Significantly lower enhancement (ie, lower R1 values, where R1=1/T1) was detected post-elastin-specific magnetic resonance contrast agent in Fbn1(C1039G/+) compared with wild-type ascending aortas (1.15±0.07 versus 1.36±0.05; P<0.05). Post-elastin-specific magnetic resonance contrast agent R1 values correlated with ascending aortic wall gadolinium content directly measured by inductively coupled mass spectroscopy (P=0.006). CONCLUSIONS: Herein, we demonstrate that MRI with elastin-specific magnetic resonance contrast agent accurately measures elastin bound gadolinium within the aortic wall and detects a decrease in aortic wall elastin in Marfan mice compared with wild-type controls. This approach has translational potential for noninvasively assessing aneurysm tissue changes and risk, as well as monitoring elastin content in response to therapeutic interventions.


Assuntos
Aorta Torácica/química , Aneurisma da Aorta Torácica/diagnóstico , Dissecção Aórtica/diagnóstico , Meios de Contraste , Elastina/deficiência , Imageamento por Ressonância Magnética/métodos , Síndrome de Marfan/complicações , Dissecção Aórtica/etiologia , Dissecção Aórtica/metabolismo , Animais , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/metabolismo , Quelantes , Modelos Animais de Doenças , Elastina/análise , Estudos de Viabilidade , Compostos Heterocíclicos com 1 Anel , Masculino , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes
8.
Radiology ; 271(2): 390-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24475852

RESUMO

PURPOSE: To compare delayed-enhancement (DE) magnetic resonance (MR) imaging with an elastin-specific contrast agent and unenhanced black-blood (BB) MR imaging with regard to vessel wall delineation and assessment of vascular remodeling and to test the prospective value for predicting plaque disruption in a rabbit model of atherosclerosis. MATERIALS AND METHODS: All procedures were approved by the animal ethics committee. Atherosclerosis was induced in 14 New Zealand White rabbits by means of a 1% cholesterol diet and endothelial denudation. Plaque disruption was triggered with Russell's viper venom and histamine. Animals with atherosclerosis were imaged before triggering to identify plaques and vascular remodeling and after triggering to identify thrombus. Plaques were classified as nondisrupted (stable) or disrupted (vulnerable). Control rabbits fed a regular diet were imaged twice. Unenhanced T1-weighted BB MR imaging, DE MR imaging with an elastin-specific contrast agent, and T1 mapping were used to assess vascular remodeling and calculate the plaque area and vessel wall relaxation rate (R1 = 1/T1). Elastin was quantified by using elastica-van Gieson stain. Group comparisons were analyzed with the Mann-Whitney or paired t test. Agreement between methods was performed with Bland-Altman analysis. RESULTS: Unenhanced T1-weighted BB MR imaging and DE MR imaging showed that, compared with nondisrupted plaques, disrupted plaques had larger plaque area (T1-weighted BB MR imaging: 5.1 mm(2) vs 5.7 mm(2); DE MR imaging: 6.0 mm(2) vs 7.9 mm(2); P < .001) and vessel area (T1-weighted BB MR imaging: 11.8 mm(2) vs 14.3 mm(2); DE MR imaging: 10.8 mm(2) vs 13.9 mm(2); P < .001) and underwent positive remodeling. Assessment of positive remodeling with DE MR imaging enabled better prediction of plaque disruption compared to that with unenhanced T1-weighted BB imaging (sensitivity: 83.7% vs 58.1%). DE MR imaging showed a stronger agreement with histologic findings, whereas the vessel area was overestimated with unenhanced T1-weighted BB imaging. CONCLUSION: Compared with unenhanced T1-weighted BB MR imaging, DE MR imaging with an elastin-specific contrast agent enables more accurate assessment of vascular remodeling in the prediction of vulnerable plaque.


Assuntos
Aorta Abdominal/patologia , Meios de Contraste/farmacologia , Angiografia por Ressonância Magnética/métodos , Placa Aterosclerótica/patologia , Animais , Colesterol na Dieta/administração & dosagem , Modelos Animais de Doenças , Elastina , Processamento de Imagem Assistida por Computador , Estudos Prospectivos , Coelhos
9.
Circ Cardiovasc Imaging ; 7(2): 321-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24363356

RESUMO

BACKGROUND: To prospectively evaluate an elastin-specific MR contrast agent (ESMA) for in vivo targeting of elastic fibers in myocardial infarction (MI) and postinfarction scar remodeling. METHODS AND RESULTS: MI was induced in C57BL/6J mice (n=40) by permanent ligation of the left anterior descending coronary artery. MRI was performed at 7 and 21 days after MI. The merits of gadolinium-based ESMA (Gd-ESMA) were compared with gadopentetic acid (Gd-DTPA) for infarct size determination, contrast-to-noise ratio (CNR), and enhancement kinetics. Specific binding in vivo was evaluated by blocking the molecular target using nonparamagnetic lanthanum-ESMA. In vivo imaging results were confirmed by postmortem triphenyltetrazolium chloride staining, elastica van Gieson staining, and Western blotting. Delayed enhancement MRI revealed prolonged enhancement of Gd-ESMA in the postischemic scar compared with Gd-DTPA. Infarct size measurements showed good agreement between Gd-ESMA and Gd-DTPA and were confirmed by ex vivo triphenyltetrazolium chloride staining. Preinjection of the blocking lanthanum-ESMA resulted in significantly lower CNR of Gd-ESMA at the infarct site (P=0.0019). Although no significant differences in CNR were observed between delayed enhancement imaging and Gd-DTPA between days 7 and 21 (1.8± versus 3.8; P=ns), Gd-ESMA showed markedly higher CNR on day 21 after MI (14.1 versus 4.9; P=0.0032), which correlated with increased synthesis of tropoelastin detected by Western blot analysis and histology. Higher CNR values for Gd-ESMA further correlated with improved ejection fraction of the mice on day 21 after MI. CONCLUSIONS: Gd-ESMA enables targeting of elastin within the infarct scar in a mouse model of MI. The imaging properties of Gd-ESMA allow quantification of intrascar elastin content in vivo and thereby provide potential for noninvasive characterization of postinfarction scar remodeling.


Assuntos
Cicatriz/diagnóstico , Vasos Coronários/patologia , Tecido Elástico/patologia , Gadolínio DTPA , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Animais , Cicatriz/etiologia , Meios de Contraste , Modelos Animais de Doenças , Elastina , Feminino , Seguimentos , Camundongos , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/complicações , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
10.
J Magn Reson Imaging ; 36(6): 1362-71, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22865680

RESUMO

PURPOSE: To accelerate the acquisition of three-dimensional (3D) high-resolution cardiovascular molecular MRI by using Compressed Sensing (CS) reconstruction. MATERIALS AND METHODS: Molecular MRI is an emerging technique for the early assessment of cardiovascular disease. This technique provides excellent soft tissue differentiation at a molecular and cellular level using target-specific contrast agents (CAs). However, long scan times are required for 3D molecular MRI. Parallel imaging can be used to speed-up these acquisitions, but hardware considerations limit the maximum acceleration factor. This limitation is important in small-animal studies, where single-coils are commonly used. Here we exploit the sparse nature of molecular MR images, which are characterized by localized and high-contrast biological target-enhancement, to accelerate data acquisition. CS was applied to detect: (a) venous thromboembolism and (b) coronary injury and aortic vessel wall in single- and multiple-coils acquisitions, respectively. RESULTS: Retrospective undersampling showed good overall image quality with accelerations up to four for thrombus and aortic images, and up to three for coronary artery images. For higher acceleration factors, features with high CA uptake were still well recovered while low affinity targets were less preserved with increased CS undersampling artifacts. Prospective undersampling was performed in an aortic image with acceleration of two, showing good contrast and well-defined tissue boundaries in the contrast-enhanced regions. CONCLUSION: We demonstrate the successful application of CS to preclinical molecular MR with target specific gadolinium-based CAs using retrospective (accelerations up to four) and prospective (acceleration of two) undersampling.


Assuntos
Compressão de Dados/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem Molecular/métodos , Infarto do Miocárdio/patologia , Disfunção Ventricular Esquerda/patologia , Algoritmos , Animais , Meios de Contraste/farmacocinética , Feminino , Gadolínio DTPA/farmacocinética , Aumento da Imagem/métodos , Camundongos , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/complicações , Infarto do Miocárdio/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/metabolismo
11.
Invest Radiol ; 47(7): 438-44, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22627945

RESUMO

OBJECTIVE: The aim of this study was to demonstrate the feasibility of high-resolution 3-dimensional aortic vessel wall imaging using a novel elastin-specific magnetic resonance contrast agent (ESMA) in a large animal model. MATERIALS AND METHODS: The thoracic aortic vessel wall of 6 Landrace pigs was imaged using a novel ESMA and a nonspecific control agent. On day 1, imaging was performed before and after the administration of a nonspecific control agent, gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA; Bayer Schering AG, Berlin, Germany). On day 3, identical scans were repeated before and after the administration of a novel ESMA (Lantheus Medical Imaging, North Billerica, Massachusetts). Three-dimensional inversion recovery gradient echo delayed-enhancement imaging and magnetic resonance (MR) angiography of the thoracic aortic vessel wall were performed on a 1.5-T MR scanner (Achieva; Philips Medical Systems, the Netherlands). The signal-to-noise ratio and the contrast-to-noise ratio of arterial wall enhancement, including the time course of enhancement, were assessed for ESMA and Gd-DTPA. After the completion of imaging sessions, histology, electron microscopy, and inductively coupled plasma mass spectroscopy were performed to localize and quantify the gadolinium bound to the arterial vessel wall. RESULTS: Administration of ESMA resulted in a strong enhancement of the aortic vessel wall on delayed-enhancement imaging, whereas no significant enhancement could be measured with Gd-DTPA. Ninety to 100 minutes after the administration of ESMA, significantly higher signal-to-noise ratio and contrast-to-noise ratio could be measured compared with the administration of Gd-DTPA (45.7 ± 9.6 vs 13.2 ± 3.5, P < 0.05 and 41.9 ± 9.1 vs 5.2 ± 2.0, P < 0.05). A significant correlation (0.96; P < 0.01) between area measurements derived from ESMA scans and aortic MR angiography scans could be found. Electron microscopy and inductively coupled plasma mass spectroscopy confirmed the colocalization of ESMA with elastic fibers. CONCLUSION: We demonstrate the feasibility of aortic vessel wall imaging using a novel ESMA in a large animal model under conditions resembling a clinical setting. Such an approach could be useful for the fast 3-dimensional assessment of the arterial vessel wall in the context of atherosclerosis, aortic aneurysms, and hypertension.


Assuntos
Aorta Torácica/patologia , Meios de Contraste , Elastina , Imageamento Tridimensional/métodos , Animais , Doenças da Aorta/diagnóstico , Doenças da Aorta/patologia , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Imagem Molecular , Suínos
12.
Nat Med ; 17(3): 383-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21336283

RESUMO

Atherosclerosis and its consequences remain the main cause of mortality in industrialized and developing nations. Plaque burden and progression have been shown to be independent predictors for future cardiac events by intravascular ultrasound. Routine prospective imaging is hampered by the invasive nature of intravascular ultrasound. A noninvasive technique would therefore be more suitable for screening of atherosclerosis in large populations. Here we introduce an elastin-specific magnetic resonance contrast agent (ESMA) for noninvasive quantification of plaque burden in a mouse model of atherosclerosis. The strong signal provided by ESMA allows for imaging with high spatial resolution, resulting in accurate assessment of plaque burden. Additionally, plaque characterization by quantifying intraplaque elastin content using signal intensity measurements is possible. Changes in elastin content and the high abundance of elastin during plaque development, in combination with the imaging properties of ESMA, provide potential for noninvasive assessment of plaque burden by molecular magnetic resonance imaging (MRI).


Assuntos
Aterosclerose/metabolismo , Meios de Contraste , Elastina/metabolismo , Aterosclerose/patologia , Elastina/farmacocinética , Humanos , Imageamento por Ressonância Magnética , Espectrometria de Massas , Distribuição Tecidual , Túnica Íntima/patologia
13.
Bioconjug Chem ; 15(2): 235-41, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15025518

RESUMO

90Y-TA138 is a (90)Y-labeled nonpeptide integrin alpha(v)beta(3) receptor antagonist that binds with high affinity and specificity to integrin alpha(v)beta(3) receptors overexpressed on both endothelial and tumor cells. (90)Y-TA138 has demonstrated significant therapeutic effects in several preclinical tumor-bearing animal models. Since (90)Y is a pure beta-emitter, (111)In-TA138 has been chosen as the imaging surrogate for dosimetry determination of (90)Y-TA138. This report describes the synthesis of (111)In-TA138 and biological evaluations of both (111)In-TA138 and (90)Y-TA138 in the c-neu Oncomouse model. The HPLC data shows that (111)In-TA138 is more hydrophilic with the retention time approximately 4.5 min shorter than that of (90)Y-TA138 under identical chromatographic conditions. Since the only difference between (111)In-TA138 and (90)Y-TA138 is the metal ion, the HPLC retention time difference strongly suggests that indium and yttrium chelates do not share the same coordination sphere in solution even though they are coordinated by the same DOTA conjugate. Despite their differences in lipophilicity and solution structure, biodistribution data in the c-neu Oncomouse model clearly showed that (111)In-TA138 and (90)Y-TA138 are biologically equivalent with respect to their uptake in tumors and other major organs. Therefore, (111)In-TA138 is useful as an imaging surrogate for (90)Y-TA138 and should be able to predict the radiation dosimetry of (90)Y-TA138, a therapeutic radiopharmaceutical for treatment of rapidly growing tumors.


Assuntos
Compostos Heterocíclicos com 1 Anel/metabolismo , Integrina alfaVbeta3/metabolismo , Sulfonamidas/metabolismo , Animais , Modelos Animais de Doenças , Genes erbB-2 , Radioisótopos de Índio/metabolismo , Integrina alfaVbeta3/antagonistas & inibidores , Camundongos , Camundongos Transgênicos , Neoplasias Experimentais/genética , Neoplasias Experimentais/metabolismo , Equivalência Terapêutica , Distribuição Tecidual , Radioisótopos de Ítrio/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...