Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 11, 2023 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-36593342

RESUMO

Gliadel occasionally induces edema following its implantation. We aimed to correlate such post-surgical radiological changes to its efficacy and subsequent survival. Fifty-six patients with recurrent high grade glioma were treated between 2005 and 2016 with Gliadel implantation. Volumetric measurements of MRI features, including FLAIR abnormalities, tumor bulk (volume of gadolinium enhancement on T1) and resection cavity volumes over time were conducted. To assess dynamics over time, linear regression trendlines for each of these were calculated and examined to correlate with survival. Median follow-up after resection was 21.5 months. Median survival post-Gliadel implantation and overall survival since diagnosis were 12 months and 22 months, respectively. A subgroup of patients (n = 6) with a transient increase in FLAIR changes volume over time survived significantly longer post-Gliadel compared to those who did not demonstrate such change (36 vs 12 months, p = .03). Positive trends, representing overall growth in volume over time, of tumor bulk and resection cavity predicted survival in multivariate analyses (hazard ratios 7.9 and 84, p = .003 and .002, respectively). Increase in tumor bulk and resection cavity over time were associated with decreased survival, while transient FLAIR increase was a favorable prognostic factor. This may represent a transient inflammatory process in the tumor, possibly stemming from a presumed immune-mediated anti-tumor response.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/tratamento farmacológico , Antineoplásicos Alquilantes/uso terapêutico , Relevância Clínica , Meios de Contraste/uso terapêutico , Gadolínio , Glioma/diagnóstico por imagem , Glioma/cirurgia , Glioma/tratamento farmacológico , Estudos Retrospectivos
2.
J Neurosurg ; 134(5): 1650-1657, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503002

RESUMO

OBJECTIVE: Previous studies have demonstrated the importance of intracranial elastance; however, methodological difficulties have limited widespread clinical use. Measuring elastance may offer potential benefit in helping to identify patients at risk for untoward intracranial pressure (ICP) elevation from small rises in intracranial volume. The authors sought to develop an easily used method that accounts for the changing ICP that occurs over a cardiac cycle and to assess this method in a large-animal model over a broad range of ICPs. METHODS: The authors used their previously described cardiac-gated intracranial balloon pump and swine model of cerebral edema. In the present experiment they measured elastance at 4 points along the cardiac cycle-early systole, peak systole, mid-diastole, and end diastole-by using rapid balloon inflation to 1 ml over an ICP range of 10-30 mm Hg. RESULTS: The authors studied 7 swine with increasing cerebral edema. Intracranial elastance rose progressively with increasing ICP. Peak-systolic and end-diastolic elastance demonstrated the most consistent rise in elastance as ICP increased. Cardiac-gated elastance measurements had markedly lower variance within swine compared with non-cardiac-gated measures. The slope of the ICP-elastance curve differed between swine. At ICP between 20 and 25 mm Hg, elastance varied between 8.7 and 15.8 mm Hg/ml, indicating that ICP alone cannot accurately predict intracranial elastance. CONCLUSIONS: Measuring intracranial elastance in a cardiac-gated manner is feasible and may offer an improved precision of measure. The authors' preliminary data suggest that because elastance values may vary at similar ICP levels, ICP alone may not necessarily best reflect the state of intracranial volume reserve capacity. Paired ICP-elastance measurements may offer benefit as an adjunct "early warning monitor" alerting to the risk of untoward ICP elevation in brain-injured patients that is induced by small increases in intracranial volume.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Complacência (Medida de Distensibilidade) , Hipertensão Intracraniana/fisiopatologia , Pressão Intracraniana , Animais , Variação Biológica Individual , Edema Encefálico/complicações , Edema Encefálico/fisiopatologia , Diástole , Encefalocele/etiologia , Encefalocele/prevenção & controle , Desenho de Equipamento , Feminino , Hipertensão Intracraniana/etiologia , Suínos , Sístole , Pesquisa Translacional Biomédica
3.
J Neurosurg ; 132(5): 1606-1615, 2019 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-30978692

RESUMO

OBJECTIVE: Augmenting brain perfusion or reducing intracranial pressure (ICP) dose is the end target of many therapies in the neuro-critical care unit. Many present therapies rely on aggressive systemic interventions that may lead to untoward effects. Previous studies have used a cardiac-gated intracranial balloon pump (ICBP) to model hydrocephalus or to flatten the ICP waveform. The authors sought to sought to optimize ICBP activation parameters to improve cerebral physiological parameters in a swine model of raised ICP. METHODS: The authors developed a cardiac-gated ICBP in which the volume, timing, and duty cycle (time relative to a single cardiac cycle) of balloon inflation could be altered. They studied the ICBP in a swine model of elevated ICP attained by continuous intracranial fluid infusion with continuous monitoring of systemic and cerebral physiological parameters, and defined two specific protocols of ICBP activation. RESULTS: Eleven swine were studied, 3 of which were studied to define the optimal timing, volume, and duty cycle of balloon inflation. Eight swine were studied with two defined protocols at baseline and with ICP gradually raised to a mean of 30.5 mm Hg. ICBP activation caused a consistent modification of the ICP waveform. Two ICBP activation protocols were used. Balloon activation protocol A led to a consistent elevation in cerebral blood flow (8%-25% above baseline, p < 0.00001). Protocol B resulted in a modest reduction of ICP over time (8%-11%, p < 0.0001) at all ICP levels. Neither protocol significantly affected systemic physiological parameters. CONCLUSIONS: The preliminary results indicate that optimized protocols of ICBP activation may have beneficial effects on cerebral physiological parameters, with minimal effect on systemic parameters. Further studies are warranted to explore whether ICBP protocols may be of clinical benefit in patients with brain injuries with increased ICP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...