Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Am J Cardiol ; 204: 84-91, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37541152

RESUMO

Acute coronary syndrome (ACS) is associated with a high incidence of unstable plaques beyond the culprit lesion, leading to early recurrence of cardiovascular events. Coronary computed tomography angiography (CCTA) can be used to noninvasively observe plaques throughout the coronary arteries. To evaluate the impact of intensive low-density lipoprotein cholesterol (LDL-C)-lowering therapy on quantitative changes in coronary plaque, assessed using CCTA in a study population with ACS. In total, 81 consecutive patients with ACS who underwent CCTA at discharge and at 1-year follow-up from April 2018 to March 2020 were analyzed. The patients were divided into 2 groups: those who achieved LDL-C <70 mg/100 ml and those who did not. Changes in plaque morphology within and between the 2 groups were compared using CCTA. A total of 198 vessels were analyzed. The calcified plaque volume was significantly increased in the LDL-C <70 group (65.8 ± 80.1 mm3 to 73.6 ± 83.7 mm3, p = 0.007), whereas no significant change was observed in the LDL-C ≥70 group (106.9 ± 161.7 mm3 to 105.7 ± 137.5 mm3, p = 0.552). Percent change in low-attenuation plaque volume in the LDL <70 group was significantly lower than in the LDL-C ≥70 group (17.2 ± 90.9% vs 84.4 ± 162.6%, p = 0.020). Receiver operating characteristic curve analysis demonstrated that the target LDL-C level for low-attenuation plaque volume regression was 64 mg/100 ml. In conclusion, noninvasive CCTA demonstrated that intensive LDL-C lowering in high-risk patients with ACS could potentially lead to plaque stabilization.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , LDL-Colesterol , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Síndrome Coronariana Aguda/tratamento farmacológico , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/tratamento farmacológico , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/tratamento farmacológico , Angiografia Coronária/métodos
2.
Heart Rhythm ; 19(5): 719-727, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34968740

RESUMO

BACKGROUND: The efficacy of catheter ablation from the noncoronary aortic cusp (NCC) of verapamil-sensitive atrial tachycardia arising near the atrioventricular node (AVN-AT) has yet to be fully clarified. OBJECTIVE: We elucidated the determinant of an effective AVN-AT ablation from the NCC. METHODS: After identifying the earliest atrial activation site (EAAS) during tachycardia, the direction of the slow conduction zone (SCZ) of the reentry circuit was identified by demonstrating manifest entrainment in 26 patients with AVN-AT. Catheter ablation was initially performed from the NCC irrespective of the local activation time. If NCC ablation was ineffective, catheter ablation was performed targeting the SCZ entrance. Then the anatomical relationship between the SCZ and the successful ablation site was elucidated. RESULTS: NCC catheter ablation terminated AVN-AT in 14 patients (NCC group) but not in 12 (non-NCC group). Catheter ablation targeting the SCZ entrance terminated all non-NCC group ATs. The local activation time at the NCC relative to the EAAS did not differ between the NCC and non-NCC groups (10.1 ± 6.5 ms vs 11.2 ± 4.8 ms; P = .6333). The direction of the SCZ was posterior to the EAAS in all NCC group patients; however, it was posterolateral (n = 5) and lateral (n = 7) to the EAAS in the non-NCC group, suggesting that the SCZ existed in the direction of the NCC in the NCC group but was away from the NCC in the non-NCC group. CONCLUSION: A close proximity between the NCC and the SCZ of the reentry circuit, but not the local activation time at the NCC, determined the efficacy of NCC catheter ablation in AVN-ATs.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Nó Atrioventricular , Eletrocardiografia , Humanos , Taquicardia , Verapamil/farmacologia , Verapamil/uso terapêutico
3.
Circ Rep ; 3(12): 716-723, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34950797

RESUMO

Background: The optimal site for measuring computed tomography (CT)-derived fractional flow reserve (FFRCT) to detect significant coronary artery disease (CAD) remains unknown. We investigated how diagnostic performance changes with FFRCT measurement site. Methods and Results: The diagnostic performance of FFRCT, measured 1-2 cm distal to the stenosis vs. a far-distal site, in detecting significant CAD with invasive fractional flow reserve ≤0.8 was evaluated in 254 diseased vessels from 146 patients with stable or suspected CAD diagnosed by coronary CT angiography. Receiver operating characteristic curve analysis revealed a significantly larger area under the curve for FFRCT measured 1-2 cm distal to the stenosis than at a far-distal site (0.829 vs. 0.791, respectively; P=0.0305). The rate of reclassification of positive FFRCT was 19% for measurements made 1-2 cm distal to the stenosis, and diagnostic accuracy for FFRCT 0.71-0.80 improved from 36% to 58% (P=0.0052). Vessel-based diagnostic accuracy of FFRCT 1-2 cm distal to the stenosis and at a far-distal site was 75% and 65%, respectively (P<0.0001), with corresponding sensitivity of 87% and 94% (P=0.0039), specificity of 60% and 29% (P<0.0001), a positive predictive value of 73% and 62% (P=0.028), and a negative predictive value of 78% and 79% (P=0.958). Conclusions: Our data suggest measuring FFRCT 1-2 cm distal to the stenosis has better diagnostic performance for detecting physiologically significant CAD.

4.
Am J Cardiol ; 159: 36-43, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34503820

RESUMO

Fraction flow reserve (FFR) derived from computed tomography (FFRCT) has been proposed to be an effective gatekeeper for invasive angiographic referral. The purpose of the present study is to examine the real-world diagnostic performance of FFRCT and myocardial perfusion imaging as well as to assess the utility of FFRCT as a gatekeeper for invasive coronary angiography in patients suspected of having obstructive coronary artery disease. Total of 146 consecutive patients underwent both single-photon emission computed tomography (SPECT) and invasive FFR were evaluated. An FFRCT value 1 to 2 cm distal to a stenosis ≤0.80 was defined as positive for ischemia and a summed stress score ≥2 or transient ischemic dilatation ≥1.2 were positive for ischemia with the invasive FFR value of <0.80 serving as the gold standard. The patient-based sensitivity of FFRCT was significantly higher than SPECT (91 vs 52%, p <0.001) and exhibited similar positive predictive value (82 vs 82%, p = 0.91). These trends were observed even in patients with multivessel and left main trunk disease and those with severe coronary calcification. In conclusion, our data suggest that FFRCT has higher diagnostic performance characteristics than SPECT and details the superior FFRCT analysis in detecting patients with hemodynamically significant coronary artery disease. Our results support the clinical utility of FFRCT analysis as a gatekeeper for invasive coronary angiography in clinical practice.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Heart Vessels ; 36(8): 1201-1211, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33512600

RESUMO

Verapamil-sensitive atrial tachycardia originating from the atrioventricular node vicinity (AVN-AT) can be eliminated with radiofrequency energy (RF) deliveries targeting either the entrance or exit of its reentry circuit. However, the outcome of these different approaches has not been clarified well. Thus, we compared the catheter ablation outcome targeting the entrance of reentry circuit, identified by the entrainment method (Ent-Group; 21 patients) with that targeting the earliest atrial activation site (EAAS) during AT (Exit-Group; 16 patients). There was no significant difference in the tachycardia cycle length (441.4 ± 87.4 vs. 392.8 ± 64.8 ms, p = 0.0704) or distance from the His bundle (HB) site to the EAAS (6.5 ± 2.0 vs. 7.6 ± 1.8 mm, p = 0.0822) between the Ent- and Exit-Groups. However, distance from the successful ablation site to the HB site in the Ent-Group was significantly longer than that in the Exit-Group (13.4 ± 3.1 vs. 7.6 ± 1.8 mm, p < 0.0001), resulting in more frequent transient atrioventricular block episodes in the Exit-Group than Ent-Group (31.3 vs. 0%, p < 0.01). Initial ATs (AT1s) were terminated in all patients in both Groups. However, ATs accompanied by shifting in the EAAS (AT2) were induced more frequently in the Exit-Group than Ent-Group (50.0 vs. 14.3%, p < 0.02) after eliminating AT1. RF deliveries to the EAAS eliminated all AT2s. The number of RF deliveries was greater in the Exit-Group than Ent-Group (6.9 ± 3.3 vs. 3.9 ± 1.6, p < 0.001). In conclusion, RF ablation targeting the entrance sites can avoid AVN injury and is superior in reducing the number of RF deliveries and occurrence of different ATs than targeting the exit sites in the AVN-AT.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Nó Atrioventricular/cirurgia , Eletrocardiografia , Humanos , Taquicardia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Verapamil/uso terapêutico
6.
Heart Vessels ; 35(12): 1650-1656, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32524237

RESUMO

Fractional flow reserve (FFR) has become an increasingly important index for decision making concerning coronary revascularization. It is commonly accepted that significant improvement in FFR following percutaneous coronary intervention (PCI) is associated with better symptomatic relief and a lower event rate. However, in lesions with insufficient FFR improvement, PCI may not improve prognosis. Leading to the observation that the clinical and angiographic characteristics associated with insufficient FFR improvement have not been fully explored. The purpose of this study was to investigate the factors associated with insufficient improvement in FFR. Using our own PCI database, established between January 2014 and December 2018, we identified 220 stable coronary artery lesions, which had been evaluated for both pre- and post-PCI FFR values. All 220 of these lesions were included in this study. The improvement in FFR (ΔFFR) was calculated in each lesion with the lowest quartile of ΔFFR being defined as the lowest ΔFFR group, and the other quartiles being defined as the intermediate-high ΔFFR group. The mean ΔFFR in the lowest and intermediate-high ΔFFR groups was 0.07 ± 0.02 and 0.21 ± 0.11, respectively. In multivariate logistic regression analysis, a short total stent length (10 mm increase: OR 0.67, 95% CI 0.47-0.96, P = 0.030), higher pre-PCI FFR (0.1 increase: OR 4.07, 95% CI 1.83-9.06, P = 0.001), in-stent restenosis (ISR) (OR 8.02, 95% CI 1.26-51.09, P = 0.028), myocardial infarction (MI) in the target vessel (OR 6.87, 95% CI 1.19-39.69, P = 0.031) and non-use of intravascular imaging (OR 0.35, 95% CI 0.12-0.99, P = 0.048) were significantly associated with the lowest ΔFFR group. The use of short stents, higher pre-PCI FFR values, ISR, MI in the target vessel, and non-use of intravascular imaging were significantly associated with insufficient FFR improvement. It was conversely suggested that full coverage and adequate dilatation of the lesions under an intravascular imaging guidance might contribute to an improvement in FFR.


Assuntos
Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Bases de Dados Factuais , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Ultrassonografia de Intervenção
7.
Heart Vessels ; 35(7): 894-900, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31956935

RESUMO

The clinical benefits of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) is still controversial. The purpose of this study is to assess the quantitative therapeutic benefits of successful PCI for CTO from the clinical data acquired by myocardial perfusion imaging (MPI). Consecutive 42 patients, who were successfully revascularized of CTO between August 2013 and March 2018, were examined. A stress MPI was performed before CTO PCI and at follow-up, and the changes in quantitative gated and perfusion single photon emission computed tomography parameters were examined. The follow-up interval was 18 ± 9 (median 14) months, during which 36 patients were maintained patency (patent CTO), while 6 were re-occluded (R/O CTO). The reduction in the % myocardial ischemia and the improvement in the ejection fraction were significantly higher in the patent CTO group than those in the R/O CTO group (67.5 ± 37.0% vs. - 56.4 ± 84.9%, p < 0.0001, 20.7 ± 49.8% vs. - 9.2 ± 20.6%, p = 0.0247, respectively). Interestingly, the improvements we observed were predominantly in the patients with LAD CTO rather than those with RCA or LCx CTO. Successful CTO PCI was able to reduce myocardial ischemia and improve the cardiac function when the patency after CTO PCI was maintained, with the most notable significance in the patients with LAD CTO.


Assuntos
Circulação Coronária , Oclusão Coronária/terapia , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Tomografia Computadorizada de Emissão de Fóton Único , Adenosina/administração & dosagem , Idoso , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Recidiva , Sistema de Registros , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Grau de Desobstrução Vascular , Vasodilatadores/administração & dosagem , Função Ventricular Esquerda
8.
J Am Heart Assoc ; 9(2): e014472, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31928174

RESUMO

Background The anatomical tachycardia circuit of sinoatrial node reentrant tachycardia (SANRT) has not been well clarified. This study aimed to elucidate the tachycardia circuit of SANRT. Methods and Results Exit and entrance of the intranodal sinoatrial node conduction (I-SANC) of the reentry circuit were identified in 15 SANRT patients. After identifying the earliest atrial activation site (EAAS) during the tachycardia (EAAS-SANRT), rapid atrial pacing was delivered from multiple atrial sites to identify the entrainment pacing site where manifest entrainment and orthodromic capture of the EAAS-SANRT were demonstrated. Radiofrequency energy was then delivered starting at a site 2 cm proximal to the EAAS-SANRT in the direction of the entrainment pacing site and gradually advanced toward the EAAS-SANRT until tachycardia termination to localize the I-SANC entrance. The EAAS-SANRT was orthodromically captured by pacing delivered from the distal coronary sinus (n=7), high posteroseptal right atrium (n=2), low posteroseptal right atrium (n=2), low anterolateral right atrium (n=2), or coronary sinus ostium (n=2). Radiofrequency energy delivery to the entrance of the I-SANC, 10.4±2.8 mm away from the EAAS-SANRT, terminated tachycardia immediately after onset of energy delivery (3.4±2.3 seconds). The successful ablation site was located further from the EAAS during sinus rhythm (EAAS-sinus) than the EAAS-SANRT (12.8±4.5 versus 7.2±3.1 mm; P<0.0001). Conclusions The reentry circuit of SANRT was composed of the entrance and exit of the I-SANC being located at distinctly different anatomical sites. SANRT was eliminated by radiofrequency energy delivered to the I-SANC entrance, which was further from the EAAS-sinus than I-SANC exit.


Assuntos
Potenciais de Ação , Nó Atrioventricular/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Idoso , Nó Atrioventricular/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
9.
Cardiovasc Interv Ther ; 30(2): 131-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25187341

RESUMO

Access site problems often cause serious complications in endovascular treatment. The aim of this study is to investigate whether a sheath-less nitinol stenting technique leads to reduce access site complications. This study was a single-center retrospective analysis of a prospectively maintained database. The study enrolled consecutive 98 patients with 111 lesions undergoing provisional stenting for de novo iliac artery or femoro-popliteal artery stenosis between August 2010 and November 2011. The patients were divided into two groups, a conventional procedure group and a sheath-less procedure group. The outcomes of this study were peri-procedural access site complications, initial success rate, procedure time, hemostatic time and bed-rest time. Forty-four lesions in 39 patients that treated using the sheath-less nitinol stent delivery technique were compared with 67 lesions in 59 patients treated using the conventional procedure. All procedures were successful. The incidence of pseudoaneurysm was significantly lower in the sheath-less procedure group than in the conventional procedure group (p = 0.043). However, there were no significant differences in any other complications. No significant difference was observed in the procedural time (p = 0.309). However, hemostatic time and bed-rest time were significantly shorter in the sheath-less procedure than in the conventional procedure (p < 0.0001). A sheath-less stenting technique reduced the access site incidence of pseudoaneurysm and did not increase other access site complications. Besides, this technique shortened hemostatic time and bed-rest time. The sheath-less stenting technique is considered to be a useful method for endovascular treatment.


Assuntos
Ligas , Angioplastia com Balão/instrumentação , Artéria Femoral , Artéria Ilíaca , Doença Arterial Periférica/terapia , Artéria Poplítea , Stents , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
Intern Med ; 53(1): 35-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24390525

RESUMO

Platypnea-orthodeoxia syndrome (POS) is a rare clinical condition defined by the presence of dyspnea and deoxygenation accompanying changing from a supine to an upright position. We experienced the case of a 75-year-old woman who developed severe acute dyspnea after a car accident. Detailed history taking and a physical examination offered important clues that helped to make an accurate diagnosis of POS. The mechanism of onset is unique and rare; however, it is important for clinical cardiologists to keep this possibility in mind when making a differential diagnosis.


Assuntos
Acidentes de Trânsito , Dispneia/diagnóstico , Forame Oval Patente/diagnóstico , Hipóxia/diagnóstico , Fraturas da Coluna Vertebral/diagnóstico , Vértebras Torácicas/lesões , Idoso , Dispneia/etiologia , Feminino , Forame Oval Patente/complicações , Humanos , Hipóxia/etiologia , Postura/fisiologia , Fraturas da Coluna Vertebral/complicações , Síndrome
11.
EuroIntervention ; 8(6): 708-16, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23086789

RESUMO

AIMS: We investigated the mechanism and predictors of jailed branch vessel (BV) compromise during the stenting of left main trunk (LMT) bifurcation lesions from a multidetector row computed tomography (MDCT) analysis. METHODS AND RESULTS: Eighty patients who underwent MDCT and stenting for LMT bifurcation lesions were examined. The patients were retrospectively classified into a BV stenosis (BVS; n=38) group and a non-BV stenosis (NBVS; n=42) group according to a coronary angiography obtained just after crossover stent deployment for the target vessel (TV). The angle between the LMT and TV was significantly wider in the BVS group than in the NBVS group (140.2±10.3 degree vs. 132.6±14.2 degree, p=0.0076), and the frequency of carina side plaque at the TV in the long and short axis was significantly higher in the BVS group than in the NBVS group (50.0% vs. 16.7%; p=0.0012, 63.2% vs. 38.1%; p=0.0251, respectively). In a multivariate analysis, the presence of carina side plaque at the TV in the long and short axis were independent predictors of BVS (odds ratio: 5.15, p=0.0086, odds ratio: 3.83, p=0.0231, respectively). CONCLUSIONS: The plaque distribution and morphology assessed by MDCT may provide useful information that can predict the potential compromise of the BV during treatment for an LMT bifurcation lesion.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica , Idoso , Distribuição de Qui-Quadrado , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento
12.
J Interv Cardiol ; 24(2): 165-71, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21198850

RESUMO

OBJECTIVE: To examine the long-term outcome of the stent fracture (SF) and the potential predictive factors contributing to in-stent restenosis (ISR) in the fractured stent. BACKGROUND: The SF is thought to be a higher risk of ISR in drug-eluting stent, although SF does not always develop ISR. METHODS: The consecutive 1,228 de novo lesions in 1,079 patients who underwent sirolimus-eluting stents implantation and assessed by 8 months follow-up coronary angiography were retrospectively analyzed. RESULTS: One hundred and seventeen SFs (9.5%) were identified in 100 patients and 22 (18.8%) SFs revealed ISR at the first follow-up. In addition, 16 (13.7%) developed new ISRs from 95 residual SFs without ISR prior to the second follow-up. Overall, 38 (32.5%) of all 117 SFs developed ISR, and 16 (42.1%) of 38 SFs occurred in a late phase beyond the first 8 months follow-up. A higher risk of ISR in the SF site was associated with the chronic total occlusion (ISR vs. no ISR: 34.2% vs. 16.5%, P = 0.0304), calcified lesions (55.3% vs. 34.2%, P = 0.0299), and correspondence 89.5% versus 43.0%, P < 0.0001 (SF site occurring at the original target lesion site) in the univariate analysis. The correspondence was identified as the only strong predictive factor for ISR at the SF site according to a multivariate logistic regression analysis (odds ratio 12.6, 95% confidence interval 3.82-53.5, P < 0.0001). CONCLUSIONS: SF occurring at the site of the original target lesion was a strong independent predictor of ISR. This indicates the need for a careful, long-term follow-up in those situations, even when no significant ISR is initially detected.


Assuntos
Reestenose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Isquemia Miocárdica/terapia , Falha de Prótese/efeitos adversos , Sirolimo/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Reestenose Coronária/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
JACC Cardiovasc Imaging ; 2(6): 720-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19520342

RESUMO

OBJECTIVES: This study sought to characterize coronary hyperintense plaques (HIP) using noncontrast T(1)-weighted imaging (T1WI) in cardiac magnetic resonance, which was then compared with multislice computed tomography and intravascular ultrasound. BACKGROUND: Carotid plaque components such as intraplaque hemorrhages and/or lipid-rich necrotic cores can be detected as HIP by noncontrast T1WI. Although coronary HIPs have been successfully detected using this technique, the properties of hyperintense signals in coronary plaques have not yet been systematically evaluated. METHODS: Thirty-eight lesions from 37 patients with angina pectoris who demonstrated >70% coronary stenosis on multislice computed tomography were evaluated by noncontrast T1WI using a 1.5-T magnetic resonance imager, and 25 lesions were evaluated by intravascular ultrasound. Signal intensity of coronary plaque to cardiac muscle ratio >1.0 was defined as HIP. We divided 25 lesions into the 2 groups, according to the presence or absence of HIP: HIP (n = 18) and non-HIP (n = 7) groups. RESULTS: In comparison with the non-HIP group, the HIP group demonstrated significantly higher coronary plaque to cardiac muscle ratio (1.7 +/- 0.7 vs. 0.9 +/- 0.1, p < 0.01), higher frequency of positive remodeling as observed by both multislice computed tomography (89% vs. 0%, p<0.0001) and intravascular ultrasound (94% vs. 14%, p < 0.001) and ultrasound attenuation (100% vs. 14.3%, p < 0.0001). The frequency of spotty calcification tended to be higher in HIP (89% vs. 50%, p = 0.079). The HIP group also exhibited a significantly lower computed tomography density (-23.2 +/- 20.7 Hounsfield units [HU] vs. 9.6 +/- 20.5 HU, p < 0.01). In addition, the incidence of transient slow-flow phenomena was significantly higher in the HIP group than in the non-HIP group (83% vs. 14%, p < 0.01). CONCLUSIONS: The typical HIP case was associated with ultrasound attenuation, positive remodeling, remarkably low computed tomography density, and a high incidence of slow-flow phenomena. Noncontrast T1WI in cardiac magnetic resonance imaging may be useful for the assessment of coronary plaque characterization in patients with coronary artery disease.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico , Feminino , Humanos , Masculino
14.
Catheter Cardiovasc Interv ; 73(5): 653-8, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19180660

RESUMO

BACKGROUND: Various two-stent techniques have been applied to aggressively treat bifurcation lesions as the introduction of drug-eluting stents (DES) and the importance of the bifurcation angle and three-dimensional (3D) structure has come to be recognized. Recent 64 multislice computed tomography (MSCT) technology provides accurate information about the 3D bifurcation geometry of the coronary arteries and with reproducibility. OBJECTIVES: The purpose of this study is to disclose the coronary bifurcation angle and 3D structure in humans and elucidate the importance of bifurcation angle for the crush technique using MSCT. METHODS: Two hundred and nine patients who were suspected to have angina pectoris and underwent CT angiography using MSCT were examined. The 3D-volume rendering (VR) image was reconstructed by two technicians and was used for the assessment of each coronary bifurcation angles. RESULTS: The average LMT bifurcation angles (angle LMT-LAD, angle LMT-LCx, angle LAD-LCx) were 143 +/- 13 degrees , 121 +/- 21 degrees , and 72 +/- 22 degrees , respectively, the average angle LAD-D was 138 +/- 19 degrees , the average angle LCx-OM was 134 +/- 23 degrees , the average distal RCA bifurcation angles (angle RCA-4AV, angle RCA-4PD, angle 4AV-4PD) were 152 +/- 15 degrees , 137 +/- 20 degrees , and 61 +/- 21 degrees , respectively. In addition, a percentage of steep angled bifurcation (<110 degrees ) was significantly higher in the LMT (26%) than in other bifurcations (P < 0.05). CONCLUSIONS: LMT bifurcation has been shown to have a higher rate of steep angled bifurcation in humans, it is therefore necessary to take the bifurcation angle into consideration in the case of LMT stenting. These data suggest that a bifurcation study using MSCT can clarify the 3D structure of coronary bifurcation and may provide useful information for bifurcation stenting.


Assuntos
Angina Pectoris/etiologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/terapia , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Stents
15.
Catheter Cardiovasc Interv ; 73(2): 205-11, 2009 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19085915

RESUMO

PURPOSE: We examined the importance of prolonged inflation time for optimal sirolimus-eluting stent (SES) or paclitaxel-eluting stent (PES) expansion. METHODS: Eighty-one de novo lesions deployed single SES or PES between April 2007 and March 2008 were divided into four groups; group 1: 21 SES deployed at 20 atm x 60 sec, group 2: 20 SES deployed with 2-step inflation at 20 atm x 60 sec following 20 atm x 20 sec, group 3: 20 PES deployed same as group 1, group 4: 20 PES deployed same as group 2. The minimal lumen diameter (MLD) and stent expansion ratio (SER; stent cross- sectional area at lesion/balloon cross-sectional area which was calculated according to the compliance chart at the same atmosphere as stent deployment) were compared between group 1 and group 2 in SES, between group 3 and group 4 in PES. RESULTS: The MLD of post 60 sec was significantly higher than that of post 20 sec (2.84 +/- 0.28 mm in group 1, 2.76 +/- 0.33 mm in group 2 vs. 2.54 +/- 0.33 mm in group 2; P = 0.003, 0.045, respectively and 2.94 +/- 0.28 mm in group 3, 3.00 +/- 0.34 mm in group 4 vs. 2.69 +/- 0.35 mm in group 4; P = 0.022, 0.007, respectively). The SER of post 60 sec was significantly higher than that of post 20 sec (79.3% +/- 8.5% in group 1, 80.8% +/- 7.8% in group 2 vs. 71.1% +/- 10.2% in group 2; P = 0.014, 0.011, respectively and 81.1% +/- 7.9% in group 3, 84.3% +/- 9.9% in group 4 vs. 72.6% +/- 10.5% in group 4, P = 0.011, 0.001, respectively). CONCLUSION: The prolonged delivery inflation for 60 sec may result in a more optimal stent expansion. It is therefore considered to be a useful method for deploying drug-eluting stent.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...