1.
Rinsho Byori ; 53(9): 793-801, 2005 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-16235831

RESUMO

Sysmex XE-2100 is an automated hematological analyzer with excellent features that can count platelets by both impedance and optical fluorescent method. Particularly, it is notable that platelet counts by optical fluorescent method (PLT-O) are automatically adopted when platelet counts by impedance method (PLT-I) are less than 50 x 10(3)/microl or platelets have abnormal distribution. We compared PLT-I with PLT-O, and also with microscopic counts, using the samples with thrombocytopenia. Regarding reproducibility, mean coefficient of variation values were 5.3% in both PLT-I and PLT-O, when no flags of "PLT Abn Distribution" appeared in the samples with thrombocytopenia. Coefficient of variation values was 10.4% in PLT-I and 5.9% in PLT-O, when flags of "PLT Abn Distribution" appeared in the sample with thrombocytopenia. Correlation among the data obtained by PLT-I, PLT-O and microscopic counts were excellent. When a large difference was observed between PLT-I and PLT-O, PLT-O was more closely consistent with microscopic counts. PLT-O was useful compared with PLT-I, and this system was considered to measure platelet counts more correctly in the samples with thrombocytopenia. Thus, it was suggested that reliable platelet counts could be reported even in the samples with thrombocytopenia by switching system in XE-2100.


Assuntos
Contagem de Plaquetas/métodos , Trombocitopenia/sangue , Automação , Humanos , Microscopia , Contagem de Plaquetas/normas , Reprodutibilidade dos Testes
2.
Int J Hematol ; 81(2): 159-61, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15765786

RESUMO

Two patients with advanced renal cell carcinoma underwent allogeneic hematopoietic stem cell transplantation and received cyclosporine (CSP) as part of their immunosuppressive therapy. Despite adequate renal function, both patients developed hyperkalemia. CSP was the only pharmaceutical agent to which this electrolyte abnormality could be attributed. Evaluation of renal tubule function suggested that CSP-associated isolated hyperkalemia resulted from tubular resistance to aldosterone. We propose that the presence of a single functional kidney may be a risk factor for isolated hyperkalemia due to CSP.


Assuntos
Carcinoma de Células Renais/complicações , Ciclosporina/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Hiperpotassemia/induzido quimicamente , Adulto , Carcinoma de Células Renais/terapia , Transplante de Células-Tronco Hematopoéticas/métodos , Humanos , Túbulos Renais/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Transplante Homólogo