Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38696130

RESUMO

PURPOSE: To improve reproducibility and predictive performance of PET radiomic features in multicentric studies by cycle-consistent generative adversarial network (GAN) harmonization approaches. METHODS: GAN-harmonization was developed to harmonize whole-body PET scans to perform image style and texture translation between different centers and scanners. GAN-harmonization was evaluated by application to two retrospectively collected open datasets and different tasks. First, GAN-harmonization was performed on a dual-center lung cancer cohort (127 female, 138 male) where the reproducibility of radiomic features in healthy liver tissue was evaluated. Second, GAN-harmonization was applied to a head and neck cancer cohort (43 female, 154 male) acquired from three centers. Here, the clinical impact of GAN-harmonization was analyzed by predicting the development of distant metastases using a logistic regression model incorporating first-order statistics and texture features from baseline 18F-FDG PET before and after harmonization. RESULTS: Image quality remained high (structural similarity: left kidney ≥ 0.800, right kidney ≥ 0.806, liver ≥ 0.780, lung ≥ 0.838, spleen ≥ 0.793, whole-body ≥ 0.832) after image harmonization across all utilized datasets. Using GAN-harmonization, inter-site reproducibility of radiomic features in healthy liver tissue increased at least by ≥ 5 ± 14% (first-order), ≥ 16 ± 7% (GLCM), ≥ 19 ± 5% (GLRLM), ≥ 16 ± 8% (GLSZM), ≥ 17 ± 6% (GLDM), and ≥ 23 ± 14% (NGTDM). In the head and neck cancer cohort, the outcome prediction improved from AUC 0.68 (95% CI 0.66-0.71) to AUC 0.73 (0.71-0.75) by application of GAN-harmonization. CONCLUSIONS: GANs are capable of performing image harmonization and increase reproducibility and predictive performance of radiomic features derived from different centers and scanners.

2.
J Nucl Med ; 65(4): 635-642, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38453361

RESUMO

The normalized distances from the hot spot of radiotracer uptake (SUVmax) to the tumor centroid (NHOC) and to the tumor perimeter (NHOP) have recently been suggested as novel PET features reflecting tumor aggressiveness. These biomarkers characterizing the shift of SUVmax toward the lesion edge during tumor progression have been shown to be prognostic factors in breast and non-small cell lung cancer (NSCLC) patients. We assessed the impact of imaging parameters on NHOC and NHOP, their complementarity to conventional PET features, and their prognostic value for advanced-NSCLC patients. Methods: This retrospective study investigated baseline [18F]FDG PET scans: cohort 1 included 99 NSCLC patients with no treatment-related inclusion criteria (robustness study); cohort 2 included 244 NSCLC patients (survival analysis) treated with targeted therapy (93), immunotherapy (63), or immunochemotherapy (88). Although 98% of patients had metastases, radiomic features including SUVs were extracted from the primary tumor only. NHOCs and NHOPs were computed using 2 approaches: the normalized distance from the localization of SUVmax or SUVpeak to the tumor centroid or perimeter. Bland-Altman analyses were performed to investigate the impact of both spatial resolution (comparing PET images with and without gaussian postfiltering) and image sampling (comparing 2 voxel sizes) on feature values. The correlation of NHOCs and NHOPs with other features was studied using Spearman correlation coefficients (r). The ability of NHOCs and NHOPs to predict overall survival (OS) was estimated using the Kaplan-Meier method. Results: In cohort 1, NHOC and NHOP features were more robust to image filtering and to resampling than were SUVs. The correlations were weak between NHOCs and NHOPs (r ≤ 0.45) and between NHOCs or NHOPs and any other radiomic features (r ≤ 0.60). In cohort 2, the patients with short OS demonstrated higher NHOCs and lower NHOPs than those with long OS. NHOCs significantly distinguished 2 survival profiles in patients treated with immunotherapy (log-rank test, P < 0.01), whereas NHOPs stratified patients regarding OS in the targeted therapy (P = 0.02) and immunotherapy (P < 0.01) subcohorts. Conclusion: Our findings suggest that even in advanced NSCLC patients, NHOC and NHOP features pertaining to the primary tumor have prognostic potential. Moreover, these features appeared to be robust with respect to imaging protocol parameters and complementary to other radiomic features and are now available in LIFEx software to be independently tested by others.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/terapia , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Prognóstico , Estudos Retrospectivos , Biomarcadores , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
3.
Radiology ; 310(2): e231319, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38319168

RESUMO

Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.


Assuntos
Processamento de Imagem Assistida por Computador , Radiômica , Humanos , Reprodutibilidade dos Testes , Biomarcadores , Imagem Multimodal
4.
Insights Imaging ; 15(1): 8, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38228979

RESUMO

PURPOSE: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. METHODS: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. RESULT: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. CONCLUSION: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. CRITICAL RELEVANCE STATEMENT: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. KEY POINTS: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score ( https://metricsscore.github.io/metrics/METRICS.html ) and a repository created to collect feedback from the radiomics community ( https://github.com/metricsscore/metrics ).

5.
Insights Imaging ; 14(1): 75, 2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37142815

RESUMO

Even though radiomics can hold great potential for supporting clinical decision-making, its current use is mostly limited to academic research, without applications in routine clinical practice. The workflow of radiomics is complex due to several methodological steps and nuances, which often leads to inadequate reporting and evaluation, and poor reproducibility. Available reporting guidelines and checklists for artificial intelligence and predictive modeling include relevant good practices, but they are not tailored to radiomic research. There is a clear need for a complete radiomics checklist for study planning, manuscript writing, and evaluation during the review process to facilitate the repeatability and reproducibility of studies. We here present a documentation standard for radiomic research that can guide authors and reviewers. Our motivation is to improve the quality and reliability and, in turn, the reproducibility of radiomic research. We name the checklist CLEAR (CheckList for EvaluAtion of Radiomics research), to convey the idea of being more transparent. With its 58 items, the CLEAR checklist should be considered a standardization tool providing the minimum requirements for presenting clinical radiomics research. In addition to a dynamic online version of the checklist, a public repository has also been set up to allow the radiomics community to comment on the checklist items and adapt the checklist for future versions. Prepared and revised by an international group of experts using a modified Delphi method, we hope the CLEAR checklist will serve well as a single and complete scientific documentation tool for authors and reviewers to improve the radiomics literature.

6.
Eur J Nucl Med Mol Imaging ; 50(2): 559-571, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36282298

RESUMO

PURPOSE: To evaluate whether radiomics from [18F]-FDG PET and/or MRI before re-irradiation (reRT) of recurrent head and neck cancer (HNC) could predict the occurrence and the location "in-field" or "outside" of a second locoregional recurrence (LR). METHODS: Among the 55 patients re-irradiated at curative intend for HNC from 2012 to 2019, 48 had an MRI and/or PET before the start of the reRT. Thirty-nine radiomic features (RF) were extracted from the re-irradiated GTV (rGTV) using LIFEx software. Student t tests and Spearman correlation coefficient were used to select the RF that best separate patients who recurred from those who did not, and "in-field" from "outside" recurrences. Principal component analysis involving these features only was used to create a prediction model. Leave-one-out cross-validation was performed to evaluate the models. RESULTS: After a median follow-up of 17 months, 40/55 patients had developed a second LR, including 18 "in-field" and 22 "outside" recurrences. From pre-reRT MRI, a model based on three RF (GLSZM_SZHGLE, GLSZM_LGLZE, and skewness) predicted whether patients would recur with a balanced accuracy (BA) of 83.5%. Another model from pre-reRT MRI based on three other RF (GLSZM_ LZHGE, NGLDM_Busyness, and GLZLM_SZE) predicted whether patients would recur "in-field" or "outside" with a BA of 78.5%. From pre-reRT PET, a model based on four RF (Kurtosis, SUVbwmin, GLCM_Correlation, and GLCM_Contrast) predicted the LR location with a BA of 84.5%. CONCLUSION: RF characterizing tumor heterogeneity extracted from pre-reRT PET and MRI predicted whether patients would recur, and whether they would recur "in-field" or "outside".


Assuntos
Neoplasias de Cabeça e Pescoço , Reirradiação , Humanos , Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Imageamento por Ressonância Magnética
7.
Eur Radiol ; 33(2): 959-969, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36074262

RESUMO

OBJECTIVES: To develop a visual ensemble selection of deep convolutional neural networks (CNN) for 3D segmentation of breast tumors using T1-weighted dynamic contrast-enhanced (T1-DCE) MRI. METHODS: Multi-center 3D T1-DCE MRI (n = 141) were acquired for a cohort of patients diagnosed with locally advanced or aggressive breast cancer. Tumor lesions of 111 scans were equally divided between two radiologists and segmented for training. The additional 30 scans were segmented independently by both radiologists for testing. Three 3D U-Net models were trained using either post-contrast images or a combination of post-contrast and subtraction images fused at either the image or the feature level. Segmentation accuracy was evaluated quantitatively using the Dice similarity coefficient (DSC) and the Hausdorff distance (HD95) and scored qualitatively by a radiologist as excellent, useful, helpful, or unacceptable. Based on this score, a visual ensemble approach selecting the best segmentation among these three models was proposed. RESULTS: The mean and standard deviation of DSC and HD95 between the two radiologists were equal to 77.8 ± 10.0% and 5.2 ± 5.9 mm. Using the visual ensemble selection, a DSC and HD95 equal to 78.1 ± 16.2% and 14.1 ± 40.8 mm was reached. The qualitative assessment was excellent (resp. excellent or useful) in 50% (resp. 77%). CONCLUSION: Using subtraction images in addition to post-contrast images provided complementary information for 3D segmentation of breast lesions by CNN. A visual ensemble selection allowing the radiologist to select the most optimal segmentation obtained by the three 3D U-Net models achieved comparable results to inter-radiologist agreement, yielding 77% segmented volumes considered excellent or useful. KEY POINTS: • Deep convolutional neural networks were developed using T1-weighted post-contrast and subtraction MRI to perform automated 3D segmentation of breast tumors. • A visual ensemble selection allowing the radiologist to choose the best segmentation among the three 3D U-Net models outperformed each of the three models. • The visual ensemble selection provided clinically useful segmentations in 77% of cases, potentially allowing for a valuable reduction of the manual 3D segmentation workload for the radiologist and greatly facilitating quantitative studies on non-invasive biomarker in breast MRI.


Assuntos
Neoplasias da Mama , Processamento de Imagem Assistida por Computador , Humanos , Feminino , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos
8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3227-3230, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085726

RESUMO

MRI-based radiomic models have shown promises in predicting the response to neoadjuvant chemotherapy in breast cancer. However, it is difficult to determine which information from the images contributes the most to the prediction: the distribution of gray-levels, the tumour heterogeneity, the shape of the lesions or the intensities of peritumoural regions. The purpose of this study is to dissociate the different sources of information to improve prediction results. Based on pre-treatment MR images from 103 patients, four types of 3D Volumes Of Interest were defined and arranged in multiple combinations. Combining features extracted from different regions proved to increase prediction performances. Clinical relevance- This study proposes a method based on analyses of MRI tumor heterogeneity, margins and peritumoral regions to improve the prediction of the response to neoadjuvant chemotherapy in breast cancer, which would help personalize patient treatment.


Assuntos
Neoplasias da Mama , Terapia Neoadjuvante , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Feminino , Humanos , Imageamento por Ressonância Magnética , Margens de Excisão , Registros
9.
Eur J Nucl Med Mol Imaging ; 49(11): 3787-3796, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35567626

RESUMO

PURPOSE: FDOPA PET shows good performance for the diagnosis of striatal dopaminergic denervation, making it a valuable tool for the differential diagnosis of Parkinsonism. Textural features are image biomarkers that could potentially improve the early diagnosis and monitoring of neurodegenerative parkinsonian syndromes. We explored the performances of textural features for binary classification of FDOPA scans. METHODS: We used two FDOPA PET datasets: 443 scans for feature selection, and 100 scans from a different PET/CT system for model testing. Scans were labelled according to expert interpretation (dopaminergic denervation versus no dopaminergic denervation). We built LASSO logistic regression models using 43 biomarkers including 32 textural features. Clinical data were also collected using a shortened UPDRS scale. RESULTS: The model built from the clinical data alone had a mean area under the receiver operating characteristics (AUROC) of 63.91. Conventional imaging features reached a maximum score of 93.47 but the addition of textural features significantly improved the AUROC to 95.73 (p < 0.001), and 96.10 (p < 0.001) when limiting the model to the top three features: GLCM_Correlation, Skewness and Compacity. Testing the model on the external dataset yielded an AUROC of 96.00, with 95% sensitivity and 97% specificity. GLCM_Correlation was one of the most independent features on correlation analysis, and systematically had the heaviest weight in the classification model. CONCLUSION: A simple model with three radiomic features can identify pathologic FDOPA PET scans with excellent sensitivity and specificity. Textural features show promise for the diagnosis of parkinsonian syndromes.


Assuntos
Transtornos Parkinsonianos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Denervação , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos
10.
Med Phys ; 49(6): 3816-3829, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35302238

RESUMO

BACKGROUND: Translation of predictive and prognostic image-based learning models to clinical applications is challenging due in part to their lack of interpretability. Some deep-learning-based methods provide information about the regions driving the model output. Yet, due to the high-level abstraction of deep features, these methods do not completely solve the interpretation challenge. In addition, low sample size cohorts can lead to instabilities and suboptimal convergence for models involving a large number of parameters such as convolutional neural networks. PURPOSE: Here, we propose a method for designing radiomic models that combines the interpretability of handcrafted radiomics with a sub-regional analysis. MATERIALS AND METHODS: Our approach relies on voxel-wise engineered radiomic features with average global aggregation and logistic regression. The method is illustrated using a small dataset of 51 soft tissue sarcoma (STS) patients where the task is to predict the risk of lung metastasis occurrence during the follow-up period. RESULTS: Using positron emission tomography/computed tomography and two magnetic resonance imaging sequences separately to build two radiomic models, we show that our approach produces quantitative maps that highlight the signal that contributes to the decision within the tumor region of interest. In our STS example, the analysis of these maps identified two biological patterns that are consistent with STS grading systems and knowledge: necrosis development and glucose metabolism of the tumor. CONCLUSIONS: We demonstrate how that method makes it possible to spatially and quantitatively interpret radiomic models amenable to sub-regions identification and biological interpretation for patient stratification.


Assuntos
Neoplasias Pulmonares , Sarcoma , Humanos , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
11.
J Nucl Med ; 63(2): 172-179, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34531263

RESUMO

The impact of PET image acquisition and reconstruction parameters on SUV measurements or radiomic feature values is widely documented. This scanner effect is detrimental to the design and validation of predictive or prognostic models and limits the use of large multicenter cohorts. To reduce the impact of this scanner effect, the ComBat method has been proposed and is now used in various contexts. The purpose of this article is to explain and illustrate the use of ComBat based on practical examples. We also give examples in which the ComBat assumptions are not met and, thus, in which ComBat should not be used.


Assuntos
Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Biomarcadores , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons/métodos , Prognóstico , Tomografia Computadorizada por Raios X/métodos
12.
PET Clin ; 16(4): 597-612, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34537132

RESUMO

Radiomics has undergone considerable development in recent years. In PET imaging, very promising results concerning the ability of handcrafted features to predict the biological characteristics of lesions and to assess patient prognosis or response to treatment have been reported in the literature. This article presents a checklist for designing a reliable radiomic study, gives an overview of the steps of the pipeline, and outlines approaches for data harmonization. Tips are provided for critical reading of the content of articles. The advantages and limitations of handcrafted radiomics compared with deep-learning approaches for the characterization of PET images are also discussed.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos
13.
15.
Eur Radiol ; 31(4): 2272-2280, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32975661

RESUMO

OBJECTIVE: Test a practical realignment approach to compensate the technical variability of MR radiomic features. METHODS: T1 phantom images acquired on 2 scanners, FLAIR and contrast-enhanced T1-weighted (CE-T1w) images of 18 brain tumor patients scanned on both 1.5-T and 3-T scanners, and 36 T2-weighted (T2w) images of prostate cancer patients scanned in one of two centers were investigated. The ComBat procedure was used for harmonizing radiomic features. Differences in statistical distributions in feature values between 1.5- and 3-T images were tested before and after harmonization. The prostate studies were used to determine the impact of harmonization to distinguish between Gleason grades (GGs). RESULTS: In the phantom data, 40 out of 42 radiomic feature values were significantly different between the 2 scanners before harmonization and none after. In white matter regions, the statistical distributions of features were significantly different (p < 0.05) between the 1.5- and 3-T images for 37 out of 42 features in both FLAIR and CE-T1w images. After harmonization, no statistically significant differences were observed. In brain tumors, 41 (FLAIR) or 36 (CE-T1w) out of 42 features were significantly different between the 1.5- and 3-T images without harmonization, against 1 (FLAIR) or none (CE-T1w) with harmonization. In prostate studies, 636 radiomic features were significantly different between GGs after harmonization against 461 before. The ability to distinguish between GGs using radiomic features was increased after harmonization. CONCLUSION: ComBat harmonization efficiently removes inter-center technical inconsistencies in radiomic feature values and increases the sensitivity of studies using data from several scanners. KEY POINTS: • Radiomic feature values obtained using different MR scanners or imaging protocols can be harmonized by combining off-the-shelf image standardization and feature realignment procedures. • Harmonized radiomic features enable one to pool data from different scanners and centers without a substantial loss of statistical power caused by intra- and inter-center variability. • The proposed realignment method is applicable to radiomic features from different MR sequences and tumor types and does not rely on any phantom acquisition.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Masculino , Imagens de Fantasmas
16.
MAGMA ; 34(3): 355-366, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33180226

RESUMO

OBJECTIVE: Quantitative analysis in MRI is challenging due to variabilities in intensity distributions across patients, acquisitions and scanners and suffers from bias field inhomogeneity. Radiomic studies are impacted by these effects that affect radiomic feature values. This paper describes a dedicated pipeline to increase reproducibility in breast MRI radiomic studies. MATERIALS AND METHODS: T1, T2, and T1-DCE MR images of two breast phantoms were acquired using two scanners and three dual breast coils. Images were retrospectively corrected for bias field inhomogeneity and further normalised using Z score or histogram matching. Extracted radiomic features were harmonised between coils by the ComBat method. The whole pipeline was assessed qualitatively and quantitatively using statistical comparisons on two series of radiomic feature values computed in the gel mimicking the normal breast tissue or in dense lesions. RESULTS: Intra and inter-acquisition variabilities were strongly reduced by the standardisation pipeline. Harmonisation by ComBat lowered the percentage of radiomic features significantly different between the three coils from 87% after bias field correction and MR normalisation to 3% in the gel, while preserving or improving performance of lesion classification in the phantoms. DISCUSSION: A dedicated standardisation pipeline was developed to reduce variabilities in breast MRI, which paves the way for robust multi-scanner radiomic studies but needs to be assessed on patient data.


Assuntos
Mama , Imageamento por Ressonância Magnética , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Radiology ; 295(2): 328-338, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32154773

RESUMO

Background Radiomic features may quantify characteristics present in medical imaging. However, the lack of standardized definitions and validated reference values have hampered clinical use. Purpose To standardize a set of 174 radiomic features. Materials and Methods Radiomic features were assessed in three phases. In phase I, 487 features were derived from the basic set of 174 features. Twenty-five research teams with unique radiomics software implementations computed feature values directly from a digital phantom, without any additional image processing. In phase II, 15 teams computed values for 1347 derived features using a CT image of a patient with lung cancer and predefined image processing configurations. In both phases, consensus among the teams on the validity of tentative reference values was measured through the frequency of the modal value and classified as follows: less than three matches, weak; three to five matches, moderate; six to nine matches, strong; 10 or more matches, very strong. In the final phase (phase III), a public data set of multimodality images (CT, fluorine 18 fluorodeoxyglucose PET, and T1-weighted MRI) from 51 patients with soft-tissue sarcoma was used to prospectively assess reproducibility of standardized features. Results Consensus on reference values was initially weak for 232 of 302 features (76.8%) at phase I and 703 of 1075 features (65.4%) at phase II. At the final iteration, weak consensus remained for only two of 487 features (0.4%) at phase I and 19 of 1347 features (1.4%) at phase II. Strong or better consensus was achieved for 463 of 487 features (95.1%) at phase I and 1220 of 1347 features (90.6%) at phase II. Overall, 169 of 174 features were standardized in the first two phases. In the final validation phase (phase III), most of the 169 standardized features could be excellently reproduced (166 with CT; 164 with PET; and 164 with MRI). Conclusion A set of 169 radiomics features was standardized, which enabled verification and calibration of different radiomics software. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Kuhl and Truhn in this issue.


Assuntos
Biomarcadores/análise , Processamento de Imagem Assistida por Computador/normas , Software , Calibragem , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Fenótipo , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sarcoma/diagnóstico por imagem , Tomografia Computadorizada por Raios X
18.
Front Oncol ; 10: 43, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32083003

RESUMO

Purpose: To design and validate a preprocessing procedure dedicated to T2-weighted MR images of lung cancers so as to improve the ability of radiomic features to distinguish between adenocarcinoma and other histological types. Materials and Methods: A discovery set of 52 patients with advanced lung cancer who underwent T2-weighted MR imaging at 3 Tesla in a single center study from August 2017 to May 2019 was used. Findings were then validated using a validation set of 19 additional patients included from May to October 2019. Tumor type was obtained from the pathology report after trans-thoracic needle biopsy, metastatic lymph node or metastasis samples, or surgical excisions. MR images were preprocessed using N4ITK bias field correction and by normalizing voxel intensities with fat as a reference region. Segmentation and extraction of radiomic features were performed with LIFEx software on the raw images, on the N4ITK-corrected images and on the fully preprocessed images. Two analyses were conducted where radiomic features were extracted: (1) from the whole tumor volume (3D analysis); (2) from all slices encompassing the tumor (2D analysis). Receiver operating characteristic (ROC) analysis was used to identify features that could distinguish between adenocarcinoma and other histological types. Sham experiments were also designed to control the number of false positive findings. Results: There were 31 (12) adenocarcinomas and 21 (7) other histological types in the discovery (validation) set. In 2D, preprocessing increased the number of discriminant radiomic features from 8 without preprocessing to 22 with preprocessing. 2D analysis yielded more features able to identify adenocarcinoma than 3D analysis (12 discriminant radiomic features after preprocessing in 3D). Preprocessing did not increase false positive findings as no discriminant features were identified in any of the sham experiments. The greatest sensitivity of the 2D analysis applied to preprocessed data was confirmed in the validation set. Conclusion: Correction for magnetic field inhomogeneities and normalization of voxel values are essential to reveal the full potential of radiomic features to identify the tumor histological type from MR T2-weighted images, with classification performance similar to those reported in PET/CT and in multiphase CT in lung cancers.

20.
PLoS One ; 14(3): e0214299, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30921388

RESUMO

AIM: Characterizing tumor heterogeneity with textural indices extracted from 18F-fluorodeoxyglucose positron emission tomography (FDG PET/CT) is of growing interest in oncology. Several series showed promising results to predict survival in patients with head and neck squamous cell carcinoma (HNSCC), analyzing various tumor segmentation methods and textural indices. This preliminary study aimed at assessing the inter-observer and inter-segmentation method variability of textural indices in HNSCC pre-therapeutic FDG PET/CT. MATERIALS AND METHODS: Consecutive patients with HNSCC referred in our department for a pre-therapeutic FDG PET/CT from January to March 2016 were retrospectively included. Two nuclear medicine physicians separately segmented all tumors using 3 different segmentation methods: a relative standardized uptake value (SUV) threshold (40%SUVmax), a signal-to-noise adaptive SUV threshold (DAISNE) and an image gradient-based method (PET-EDGE). SUV and metabolic tumor volume were recorded. Thirty-one textural indices were calculated using LIFEx software (www.lifexsoft.org). After correlation analysis, selected indices' inter-segmentation method and inter-observer variability were calculated. RESULTS: Forty-three patients (mean age 63.8±9.3y) were analyzed. Due to a too small segmented tumor volume of interest, textural analysis could not be performed in 6, 11 and 15 cases with respectively DAISNE, 40%SUVmax and PET-EDGE segmentation methods. Five independent textural indices were selected (Homogeneity, Correlation, Entropy, Busyness and LZLGE). There was a high inter-contouring method variability for Homogeneity, Correlation, Entropy and LZLGE (p<0.0001 for each index). The inter-observer reproducibility analysis revealed an excellent agreement for 3 indices (Homogeneity, Correlation and Entropy) with an intraclass correlation coefficient higher than 0.90 for the 3 methods. CONCLUSIONS: This preliminary study showed a high variability of 4 out of 5 textural indices (Homogeneity, Correlation, Entropy and LZLGE) extracted from pre-therapeutic FDG PET/CT in HNSCC using 3 different contouring methods. However, for each method, there was an excellent agreement between observers for 3 of these textural indices (Homogeneity, Correlation and Entropy).


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Carcinoma de Células Escamosas/diagnóstico , Feminino , Fluordesoxiglucose F18/química , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...