1.
Clin Exp Optom ; 106(1): 85-90, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35057697

RESUMO

CLINICAL RELEVANCE: There is some controversy about the utility of prescribing blue-blocking filters to mitigate digital eye strain. We found that using commercially available blue-blocking filters was ineffective in reducing orbicularis oculi muscle activity and visual symptomatology during a 30-min reading task from a computer screen. BACKGROUND: There are some claims that blue-blocking (B-B) filters may be effective in reducing symptoms and signs of digital eye strain. However, recent studies have suggested that there is no sufficient evidence to support their use. This study assessed the short-term effects of a commercially available, B-B filter on orbicularis oculi (OO) muscle activity and symptoms of digital eye strain during the execution of a 30-min reading tas. METHODS: Twenty-three healthy young adults (22.9 ± 3.2 years of age) performed two reading tasks from a computer screen with or without a B-B filter on two different days. OO muscle activity was recorded by surface electromyography 4-5, 9-10, 14-15, 19-20, 24-25 and 29-30 min into the trial. Participants reported their perceived levels of visual discomfort and activation before and after completing the reading task. RESULTS: A Bayesian analysis favoured the null hypothesis that there was no change in OO muscle activity with or without using the B-B filter (Bayes Factor01 [BF01] = 7.08). Regarding symptomatology, the analysis favoured the time model that reading increased visual fatigue and discomfort but reduced activation levels (BF01 < 0.33 in all cases). However, our data did not support the alternative model that using B-B filter affected these visual symptoms. CONCLUSIONS: The B-B filter did not alter OO muscle activity or visual symptomatology significantly during the execution of a 30-min reading task in asymptomatic subjects. These findings support the idea that B-B filters do not attenuate signs and symptoms of digital eye strain.


Assuntos
Astenopia , Humanos , Adulto Jovem , Astenopia/diagnóstico , Teorema de Bayes , Computadores , Pálpebras , Transtornos da Visão
2.
Ophthalmic Physiol Opt ; 40(6): 790-800, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33001489

RESUMO

INTRODUCTION: The prescription of blue-blocking (B-B) filters for the management of visual symptoms and signs associated with the use of electronic devices is routinely performed by eye care specialists. However, the utility of B-B filters is a matter of debate and discussion by the scientific community due to the lack of evidence supporting their use. Here, we aimed to determine the effects of using B-B filters on the dynamics of the accommodative response and pupil size and perceived levels of visual discomfort, while performing a 30-min reading task at a close distance in subjects who routinely use electronic devices. METHODS: Nineteen healthy young adults (22.0 ± 2.7 years) read two 30-min passages on a computer screen placed at 50 cm, either while using a commercially available B-B filter or without any filter on two different days. The magnitude and variability of both the accommodative response and pupil size were dynamically measured for 60 s using the WAM-5500 open field autorefractometer at 4-5, 9-10, 14-15, 19-20, 24-25, and 29-30 min into the trial. The perceived levels of visual discomfort were also obtained. RESULTS: The lag and variability of accommodation were insensitive to the blue light level (p = 0.34 and 0.62, respectively). There was a time-on-task effect for the variability of accommodation, showing greater instability over time regardless of the blue light level. The use of the B-B filter was associated with improved reading speed (p = 0.02), with an increase of 16.5 words per minute. However, it was not associated with any significant change in pupil dynamics or the perceived levels of visual discomfort (p> 0.05 in both cases). CONCLUSIONS: Our data showed that the use of a B-B filter had no effect on accommodative dynamics or visual symptomatology. Based on these findings, there is no support for the prescription of B-B filters to attenuate the visual symptoms and signs associated with the use of electronic devices in healthy young adults.


Assuntos
Acomodação Ocular/fisiologia , Astenopia/terapia , Óculos , Pupila/fisiologia , Leitura , Acuidade Visual , Astenopia/fisiopatologia , Cor , Feminino , Voluntários Saudáveis , Humanos , Luz , Masculino , Reprodutibilidade dos Testes , Adulto Jovem