Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862490

RESUMO

Fast ions play a crucial role in plasma heating, and their behavior in the plasma must be accurately understood. A diagnostics method based on charge exchange emission from the n = 4 - 3 transition (λ0 = 468.6 nm) of energetic 3He produced by the deuteron-deuteron reaction has been proposed as a for fast deuterons with energies in the order of MeV. The proposed method has the following advantages: No beam emission interferes with the spectra, the direction of the measuring line of sight, and the injection angle of the diagnostic beam can be freely determined. In previous studies, due to competing bremsstrahlung, it was expected that the proposed method will not be practical in the case of high electron density operation. This paper makes the proposed method available for measurement even at high electron densities by optimizing the measurement line of sight direction and the diagnostic beam incidence angle. This allows an electron density five times larger than the range of applications shown in previous studies. This result will contribute to measure of DT alpha in ITER.

2.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37819204

RESUMO

A fast-sampling fast-ion D-alpha (F-FIDA) measurement has been developed in the large helical device in order to investigate fast ion dynamics associated with helically trapped fast-ion-driven Magnetohydrodynamic (MHD) bursts. F-FIDA consists of a multi-anode photomultiplier tube (PMT) and achieves a sampling rate of 10 kHz. During the deuterium experiment campaign in 2022, F-FIDA measured the spectrum of perpendicular fast ions, using perpendicular lines of sight. We compared F-FIDA with conventional FIDA, using an electron multiplying charge coupled device, and confirmed that the time-averaged images were generally consistent between the two. The statistical properties of the temporal evolution associated with MHD bursts were analyzed using a conditional sampling technique. The results showed that the PMT signal varied in different spatial and wavelength channels. Although the signal-to-noise ratio was poor and there was room for improvement, it could provide useful information for studies on the phase-space dynamics of fast ions.

3.
Nat Commun ; 14(1): 955, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36804939

RESUMO

Proton-boron (p11B) fusion is an attractive potential energy source but technically challenging to implement. Developing techniques to realize its potential requires first developing the experimental capability to produce p11B fusion in the magnetically-confined, thermonuclear plasma environment. Here we report clear experimental measurements supported by simulation of p11B fusion with high-energy neutral beams and boron powder injection in a high-temperature fusion plasma (the Large Helical Device) that have resulted in diagnostically significant levels of alpha particle emission. The injection of boron powder into the plasma edge results in boron accumulation in the core. Three 2 MW, 160 kV hydrogen neutral beam injectors create a large population of well-confined, high -energy protons to react with the boron plasma. The fusion products, MeV alpha particles, are measured with a custom designed particle detector which gives a fusion rate in very good relative agreement with calculations of the global rate. This is the first such realization of p11B fusion in a magnetically confined plasma.

4.
Sci Rep ; 12(1): 15112, 2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36068266

RESUMO

Thomson scattering measurements with a high-repetition-rate laser have commenced in the Large Helical Device. As an example of the fast phenomena captured by this diagnostic system, measurements at a 20 kHz repetition-rate in hydrogen pellet-injected plasmas are presented. Signal processing methods for this measurement have been developed and electron temperature profiles with almost 70 spatial points were evaluated at time intervals of 50 [Formula: see text]s. After Raman scattering calibration, electron density profiles were derived. Fast changes in the electron temperature and density profiles within 1 ms were observed.

5.
Phys Rev Lett ; 127(22): 225001, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34889640

RESUMO

We assess the magnetic field configuration in modern fusion devices by comparing experiments with the same heating power, between a stellarator and a heliotron. The key role of turbulence is evident in the optimized stellarator, while neoclassical processes largely determine the transport in the heliotron device. Gyrokinetic simulations elucidate the underlying mechanisms promoting stronger ion scale turbulence in the stellarator. Similar plasma performances in these experiments suggests that neoclassical and turbulent transport should both be optimized in next step reactor designs.

6.
Rev Sci Instrum ; 92(5): 053524, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243281

RESUMO

The fast deuteron (non-Maxwellian component) diagnostic method, which is based on the higher resolution optical spectroscopic measurement, has been developed as a powerful tool. Owing to a decrease in the D-H charge-exchange cross section, the diagnostic ability of conventional optical diagnostic methods should be improved for ∼MeV energy deuterons. Because the 3He-H charge-exchange cross section is much larger than that of D-H in the ∼MeV energy range, the visible light (VIS) spectrum of 3He produced by the dueteron-dueteron (DD) reaction may be a useful tool. Although the density of 3He is small because it is produced via the DD reaction, improvement of the emissivity of the VIS spectrum of 3He can be expected by using a high-energy beam. We evaluate the VIS spectrum of 3He for the cases when a fast deuteron tail is formed and not formed in the ITER-like beam injected deuterium plasma. Even when the beam energy is in the MeV energy range, a large change appears in the half width at half maximum of the VIS spectrum. The emissivity of the VIS spectrum of 3He and the emissivity of bremsstrahlung are compared, and the measurable VIS spectrum is obtained. It is shown that the VIS spectrum of 3He is a useful tool for the MeV beam deuteron tail diagnostics.

7.
Rev Sci Instrum ; 91(11): 113304, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33261440

RESUMO

A diamond-based neutral particle analyzer (DNPA) array composed of single-crystal chemical vapor deposition (sCVD) diamond detectors was installed on the Large Helical Device (LHD) for measuring the helically trapped energetic particles. In high neutron flux experiments, the unwanted neutron-induced pulse counting rate should be estimated using the neutron diagnostics because a diamond detector is sensitive to neutrons as well as energetic neutral particles. In order to evaluate the quantitative neutron-induced pulse counting rate on the DNPA, the response functions of the sCVD diamond detector for mono-energetic neutrons were obtained using accelerator-based D-D and D-7Li neutron sources in Fast Neutron Laboratory (FNL). As a result of the neutron flux estimation by the Monte Carlo N-Particle code at the NPA position in the LHD and the response function obtained in the FNL experiment, the counting rate of the neutron-induced signal was predicted to be 1.1 kcps for the source neutron emission rate of Sn = 1 × 1015 n/s. In the LHD experiment, the neutron-induced signals were observed by closing the gate valve during the plasma discharges. It is found that the counting rates of the neutron-induced signals proportional to Sn reached 1.1 kcps at Sn = 1 × 1015 n/s. As a result of the quantitative estimation of the neutron-induced signals on the DNPA using other neutron measurements, it has become possible to accurately measure energetic neutral particles in the high neutron flux experiment.

8.
Rev Sci Instrum ; 91(8): 083505, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872928

RESUMO

Two new vertical neutron cameras characterized by high detection efficiency were developed on the Large Helical Device in order to observe poloidal structures of helically trapped beam ions created by the perpendicularly injected positive-ion based neutral beam (P-NB) and are newly operated since 2018. In this work, the neutron fields at the vertical neutron cameras are investigated using the Monte Carlo N-particle transport code to evaluate the performance of its collimators. The results indicate that neutrons are attenuated by the heavy concrete and are well collimated through the collimator to detectors. Neutron spectra at the detector position show over 99% of uncollided 2.45 MeV neutrons. Time evolution of neutron emission profiles during the short pulse of P-NB injection is measured by the vertical neutron cameras. Peaks on the neutron emission profiles corresponding to the helically trapped beam ion are successfully obtained, as designed. The decrease in line integrated neutron flux at the peak positions after the P-NB stops is consistent with the behavior of the total neutron emission rate measured by the neutron flux monitor.

9.
Rev Sci Instrum ; 91(2): 023503, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32113389

RESUMO

Simultaneous measurement of negative ion source plasma and extracted beam is carried out in order to clarify a key plasma parameter governing the meniscus formation in negative ion sources for fusion. The plasma discharge is performed with various discharge powers at different bias voltages in order to vary the plasma parameters. It is shown that the beam width changes along the same curve with respect to the negative ion density at any bias voltage while it varies along different curves with other plasma parameters depending on the bias voltage. This implies that the mechanism of meniscus formation in negative ion sources could be described along the similar manner as positive ion sources.

10.
Rev Sci Instrum ; 91(1): 013512, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012531

RESUMO

Density distributions of negative hydrogen (H-) ions and negative deuterium (D-) ions were measured with the laser photodetachment method in the extraction region of the negative ion source. The distribution of H- ion density peaks at the center of the ion source, while that of the D- ion shows a flatter profile in the direction parallel to the plasma grid. The positive ion densities of hydrogen and deuterium estimated from the positive saturation current indicate similar profiles with different amounts close to the grid. The difference in the H- ion and D- ion distributions can be explained by the difference in the negative ion yield and the survival probability of the ions due to the isotope effect.

11.
Phys Rev Lett ; 123(18): 185001, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31763903

RESUMO

The isotope effect on energy confinement time and thermal transport has been investigated for plasmas confined by a stellarator-heliotron magnetic field. This is the first detailed assessment of an isotope effect in a stellarator heliotron. Hydrogen and deuterium plasmas heated by neutral beam injection on the Large Helical Device have exhibited no significant dependence on the isotope mass in thermal energy confinement time, which is not consistent with the simple gyro-Bohm model. A comparison of thermal diffusivity for dimensionally similar hydrogen and deuterium plasmas in terms of the gyroradius, collisionality, and thermal pressure has clearly shown robust confinement improvement in deuterium to compensate for the unfavorable mass dependence predicted by the gyro-Bohm model.

12.
Rev Sci Instrum ; 90(11): 113322, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779449

RESUMO

Second deuterium operation of the negative ion based neutral beam injector was performed in 2018 in the large helical device. The electron and ion current ratio improves to Ie/Iacc(D) = 0.31 using the short extraction gap distance of 7 mm between the plasma grid (PG) and the extraction grid (EG). The strength of the magnetic field by the electron deflection magnet installed in the EG increases by 17% at the PG ingress surface, which effectively reduces the electron component in the negative ion rich plasma in the vicinity of PG apertures. The reduction of the electron current made it possible to operate at a high power arc discharge and beam extraction. Then, the deuterium negative ion current increases to 55.4 A with the averaged current density of 233 A/m2. The thermal load on the EG using 7 mm gap distance is 0.6 times smaller than the thermal load using a 8 mm gap caused by the reduction of coextracted electron current. The injection beam power increases to 2.9 MW in the beam line BL3, and the total beam injection power increases to 7 MW by three beam lines in the second deuterium campaign.

13.
Rev Sci Instrum ; 89(12): 123303, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30599604

RESUMO

To evaluate negative ion beam properties, a dual beamlet monitor system has been developed. The dual beamlet monitor system has two diagnostics in one hexagonal box. One diagnostic is a "fast beamlet monitor" for measuring the time evolution of beamlet current profiles with the time resolution of up to 25 MHz. The other diagnostic is a "pepper-pot-type phase space analyzer," which is applied for the evaluation of a phase space structure of the negative ion beamlet. The dual beamlet monitor system is applied to the measurement of the beamlet in the Neutral Beam Test Stand at National Institute for Fusion Science (NIFS-NBTS), in which the beam accelerator is almost identical to those of working beam injectors in the large helical device. It is demonstrated that the overlapping components from the neighboring beamlet can be eliminated, and the phase space structure can be obtained for the single beamlet.

14.
Phys Rev Lett ; 118(12): 125001, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-28388197

RESUMO

The resistive interchange mode destabilized by the resonant interaction with the trapped energetic ions is fully suppressed when the injected power of electron cyclotron heating exceeds a certain threshold. It is shown for the first time that the complete stabilization of the energetic-particle-driven mode without relaxing the energetic particle (EP) pressure gradient is possible by reducing the radial width of the eigenmodes δ_{w}, especially when δ_{w} narrows to a small enough value relative to the finite orbit width of EP.

15.
Rev Sci Instrum ; 87(11): 11E105, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910614

RESUMO

The upgraded millimeter-wave interferometer with the frequency of 70 GHz is installed on a large-scaled negative ion source. Measurable line-averaged electron density is from 2 × 1015 to 3 × 1018 m-3 in front of the plasma grid. Several improvements such as the change to shorter wavelength probing with low noise, the installation of special ordered horn antenna, the signal modulation for a high accuracy digital phase detection, the insertion of insulator, and so on, are carried out for the measurement during the beam extraction by applying high voltage. The line-averaged electron density is successfully measured and it is found that it increases linearly with the arc power and drops suddenly at the beam extraction.

16.
Rev Sci Instrum ; 87(2): 02B103, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931985

RESUMO

Experiments by a four-pin probe and photodetachment technique were carried out to investigate the charged particle flows in the beam extraction region of a negative hydrogen ion source for neutral beam injector. Electron and positive ion flows were obtained from the polar distribution of the probe saturation current. Negative hydrogen ion flow velocity and temperature were obtained by comparing the recovery times of the photodetachment signals at opposite probe tips. Electron and positive ions flows are dominated by crossed field drift and ambipolar diffusion. Negative hydrogen ion temperature is evaluated to be 0.12 eV.

17.
Rev Sci Instrum ; 87(2): 02B113, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931995

RESUMO

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (Hα) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of Hα emission near the bias plate has been clearly observed. The same time trend on Hα intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

18.
Rev Sci Instrum ; 87(2): 02B321, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932049

RESUMO

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

19.
Rev Sci Instrum ; 87(2): 02B936, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932108

RESUMO

Recent research results on negative-ion-rich plasmas in a large negative ion source have been reviewed. Spatial density and flow distributions of negative hydrogen ions (H(-)) and positive hydrogen ions together with those of electrons are investigated with a 4-pin probe and a photodetachment (PD) signal of a Langmuir probe. The PD signal is converted to local H(-) density from signal calibration to a scanning cavity ring down PD measurement. Introduction of Cs changes the slope of plasma potential local distribution depending upon the plasma grid bias. A higher electron density H2 plasma locally shields the bias potential and behaves like a metallic free electron gas. On the other hand, the bias and extraction electric fields penetrate in a Cs-seeded electronegative plasma even when the electron density is similar. Electrons are transported by the penetrated electric fields from the driver region along and across the filter and electron deflection magnetic fields. Plasma ions exhibited a completely different response against the penetration of electric fields.

20.
Phys Rev Lett ; 116(1): 015002, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26799023

RESUMO

Abrupt and strong excitation of a mode has been observed when the frequency of a chirping energetic-particle driven geodesic acoustic mode (EGAM) reaches twice the geodesic acoustic mode (GAM) frequency. The frequency of the secondary mode is the GAM frequency, which is a half-frequency of the primary EGAM. Based on the analysis of spatial structures, the secondary mode is identified as a GAM. The phase relation between the secondary mode and the primary EGAM is locked, and the evolution of the growth rate of the secondary mode indicates nonlinear excitation. The results suggest that the primary mode (EGAM) contributes to nonlinear destabilization of a subcritical mode.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...