Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Am J Health Syst Pharm ; 62(21): 2241-51, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16239414

RESUMO

PURPOSE: Clinical information regarding paclitaxel-eluting coronary artery stents is reviewed. SUMMARY: Restenosis is a significant complication of percutaneous coronary intervention. Coronary artery stenting has reduced restenosis compared with traditional balloon angioplasty, although restenosis still occurs with bare-metal coronary artery stents. The pathogenesis of in-stent restenosis is believed to involve smooth-muscle-cell proliferation and migration in response to vessel injury. A neointimal layer of extracellular matrix and collagen forms, which may impinge on the vessel lumen. Paclitaxel inhibits vascular smooth-muscle-cell proliferation and reduces neointimal mass. Local delivery of paclitaxel through a coronary stent has been shown to reduce restenosis rates and percent diameter stenosis and to produce other angiographic benefits compared with bare-metal stents. Fewer major adverse coronary events are seen with paclitaxel-eluting stents, predominantly because of a reduction in the need for target-vessel revascularization with minimal impact on rates of mortality and myocardial infarction (MI). The Taxus Express(2) stent, the only approved paclitaxel-eluting stent in the United States, costs about three times as much as a bare-metal stent. Cost-effectiveness analyses are needed to determine if the Taxus stent is cost-effective in clinical practice. CONCLUSION: Paclitaxel-eluting stents reduce the rates of restenosis and target-vessel revascularization compared with bare-metal stents and have comparable effects on mortality and MI rates.


Assuntos
Antineoplásicos/uso terapêutico , Doença da Artéria Coronariana/terapia , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Paclitaxel/uso terapêutico , Stents , Antineoplásicos/administração & dosagem , Antineoplásicos/economia , Ensaios Clínicos como Assunto , Humanos , Paclitaxel/administração & dosagem , Paclitaxel/economia , Sirolimo/uso terapêutico , Stents/efeitos adversos
3.
Pacing Clin Electrophysiol ; 27(7): 1008-10, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15271026

RESUMO

Cardiac device infections are a rare complication of pacing and defibrillator therapy. The number of implanted devices will likely continue to rise with increasing implantation of the cardioverter defibrillator and cardiac resynchronization devices. This report describes a case of an uncommon pathogen for device-associated endocarditis.


Assuntos
Endocardite Bacteriana/etiologia , Infecções por Haemophilus/etiologia , Haemophilus parainfluenzae , Marca-Passo Artificial/efeitos adversos , Adulto , Endocardite Bacteriana/diagnóstico , Infecções por Haemophilus/diagnóstico , Humanos , Masculino
5.
Cardiol Rev ; 12(1): 49-55, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14667265

RESUMO

Cardiac involvement in patients with advanced HIV/AIDS is common, including pericardial effusion and pulmonary hypertension. Although there is an increased incidence of pericardial effusion in patients with AIDS, most are small and asymptomatic. The presence of a pericardial effusion and/or pulmonary hypertension is associated with shortened survival. We present a case of a 43-year-old man with AIDS and advanced cardiovascular involvement who developed severe cor pulmonale and a large pericardial effusion with cardiac tamponade.


Assuntos
Síndrome da Imunodeficiência Adquirida/complicações , Tamponamento Cardíaco/etiologia , Hipertensão Pulmonar/etiologia , Derrame Pericárdico/etiologia , Doença Cardiopulmonar/etiologia , Adulto , Autopsia , Tamponamento Cardíaco/diagnóstico , Diagnóstico Diferencial , Ecocardiografia , Evolução Fatal , Humanos , Hipertensão Pulmonar/diagnóstico , Masculino , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/terapia , Pericardiocentese , Doença Cardiopulmonar/diagnóstico
7.
Catheter Cardiovasc Interv ; 56(2): 162-5, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12112906

RESUMO

We prospectively evaluated 59 patients who were deemed candidates for coronary bypass surgery after coronary artery angiography for subclavian artery narrowing, which could compromise the ipsilateral internal thoracic artery graft. Bilateral arm blood pressure (BP) measurements, auscultation for supraclavicular or cervical bruits, and questioning about cerebrovascular ischemic symptoms were compared to brachiocephalic-subclavian arteriography. One neurologic complication occurred during arteriography. An upper extremity BP difference of > or = 15 mm Hg identified all patients with > or = 50% subclavian artery narrowing. We recommend brachiocephalic-subclavian arteriography only in patients with abnormal noninvasive screening for subclavian stenosis, not routinely.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Ponte de Artéria Coronária , Artéria Subclávia/patologia , Idoso , Pressão Sanguínea , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Radiografia , Artéria Subclávia/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...