Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(4): e26391, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38434080

RESUMO

In diffusion magnetic resonance imaging, oscillating gradient spin echo (OGSE) has an extremely short diffusion time if motion probing gradient (MPG) is applied to the waveform. Further, it can detect microstructural specificity. OGSE changes sensitivity to spin displacement velocity based on the MPG phase. The current study aimed to investigate the restricted diffusion characteristics of each OGSE waveform using the capillary phantom with various b-values, frequencies, and MPG phases. We performed OGSE (b-value = 300, 500, 800, 1200, 1600, and 2000 s/mm2) for the sine and cosine waveforms using the capillary phantom (6, 12, 25, 50, and 100 µm and free water) with a 9.4-T experimental magnetic resonance imaging system and a solenoid coil. We evaluated the axial and radial diffusivity (AD, RD) of each structure size. The output current of the MPG was assessed with an oscilloscope and analyzed with the gradient modulation power spectra by fast Fourier transform. In sine, the sidelobe spectrum was enhanced with increasing frequency, and the central spectrum slightly increased. The difference in RD was detected at 6 and 12 µm; however, it did not depend on the structure scale at 50 or 100 µm and free water. In cosine, the diffusion spectrum was enhanced, whereas the central spectrum decreased with increasing frequency. Both AD and RD in cosine had a frequency dependence, and AD and RD increased with a higher frequency regardless of structure size. AD and RD in either sine or cosine had no evident b-value dependence. We evaluated the OGSE-restricted diffusion characteristics. The measurements obtained diffusion information similar to the pulsed gradient spin echo. Hence, the cosine measurements indicated that a higher frequency could capture faster diffusion within the diffusion phenomena.

2.
PLoS One ; 19(2): e0297273, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38300967

RESUMO

Currently, we can label the certain cells by transducing specific genes, called reporter genes, and distinguish them from other cells. For example, fluorescent protein such as green fluorescence protein (GFP) is commonly used for cell labeling. However, fluorescent protein is difficult to observe in living animals. We can observe the reporter signals of the luciferin-luciferase system from the outside of living animals using in vivo imaging systems, although the resolution of this system is low. Therefore, in this study, we examined the reporter genes, which allowed the MRI-mediated observation of labeled cells in living animals. As a preliminary stage of animal study, we transduced some groups of plasmids that coded the protein that could take and store metal ions to the cell culture, added metal ions solutions, and measured their T1 or T2 relaxation values. Finally, we specified the best reporter gene combination for MRI, which was the combination of transferrin receptor, DMT1, and Ferritin-M6A for T1WI, and Ferritin-M6A for T2WI.


Assuntos
Ferritinas , Imageamento por Ressonância Magnética , Animais , Genes Reporter , Ferritinas/genética , Linhagem Celular Tumoral , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Imageamento por Ressonância Magnética/métodos , Íons/metabolismo
3.
Magn Reson Med Sci ; 23(2): 136-145, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36754420

RESUMO

PURPOSE: Diffusion MRI is a physical measurement method that quantitatively indicates the displacement of water molecules diffusing in voxels. However, there are insufficient data to characterize the diffusion process physically in a uniform structure such as a phantom. This study investigated the transitional relationship between structure scale, temperature, and diffusion time for simple restricted diffusion using a capillary phantom. METHODS: We performed diffusion-weighted pulsed-gradient stimulated-echo acquisition mode (STEAM) MRI with a 9.4 Tesla MRI system (Bruker BioSpin, Ettlingen, Germany) and a quadrature coil with an inner diameter of 86 mm (Bruker BioSpin). We measured the diffusion coefficients (radial diffusivity [RD]) of capillary plates (pore sizes 6, 12, 25, 50, and 100 µm) with uniformly restricted structures at various temperatures (10ºC, 20ºC, 30ºC, and 40ºC) and multiple diffusion times (12-800 ms). We evaluated the characteristics of scale, temperature, and diffusion time for restricted diffusion. RESULTS: The RD decayed and became constant depending on the structural scale. Diffusion coefficient fluctuations with temperature occurred mostly under conditions of a large structural scale and short diffusion time. We obtained data suggesting that temperature-dependent changes in the diffusion coefficients follow physical laws. CONCLUSION: No water molecules were observed outside the glass tubes in the capillary plates, and the capillary plates only reflected a restricted diffusion process within the structure.We experimentally evaluated the characteristics of simple restricted diffusion to reveal the transitional relationship of the diffusion coefficient with diffusion time, structure scale, and temperature through composite measurement.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Temperatura , Imagem de Difusão por Ressonância Magnética/métodos , Difusão , Transporte Biológico , Imagens de Fantasmas , Água
4.
Heliyon ; 8(11): e11714, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36439771

RESUMO

Caffeine is a psychoactive substance that not only improves wakefulness, but also slows the cognitive decline caused by aging. However, at present, there are no reports about the effects of caffeine withdrawal, including headaches and changes in brain functional networks (nerve activity). Headache may occur approximately 24 h after discontinuing caffeine intake in chronic caffeine drinkers. The current study aimed to examine the brain functional activity via resting-state functional magnetic resonance imaging in chronically caffeinated and decaffeinated groups to investigate changes in brain activity caused by caffeine. C57BL/6J mice were included in the analysis, and they underwent 9.4-T ultrahigh-field magnetic resonance imaging. The mice were classified into the control, chronic caffeinated, and caffeine withdrawal grsoups. Mice were divided into three groups: 1) not exposed to caffeine (control); 2) treated with caffeine at a concentration of 0.3 mg/mL for 4 weeks (chronic caffeinated); and 3) treated as before with caffeine and withdrawn from caffeine for 24 h. After the three groups were examined, functional connectivity matrices were calculated using brain imaging analysis tools, and independent component analysis was performed. The results showed that caffeine administration activated neural activity areas in the stress response system. Furthermore, 24h after caffeine withdrawal, the results showed an increase in pain-related neural activity. In addition, caffeine administration was shown to activate the dentate gyrus, one of the hippocampal regions, and to decrease the neural activity in the olfactory bulb and anterior cingulate cortex. In the current research, the neural activity of specific brain regions changed after chronic caffeine administration and withdrawal.

5.
Leg Med (Tokyo) ; 49: 101836, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33476946

RESUMO

Japanese individuals have a unique culture of soaking in a bathtub, and forensic pathologists have experienced fatal cases due to drowning. However, T1 and T2 relaxation times of a drowning lung are poorly documented. In the present study, we investigated the relationship between drowning water temperature and T1 and T2 relaxation times of drowning lung tissues at 9.4 T MRI (Bruker, BioSpec94/20USR). The mice used as animal drowning models were directly submerged in freshwater. Water temperature was set to 8 °C-10 °C (cold), 20 °C-22 °C (normal), 30 °C, and 45 °C. The regions of interest (ROIs) on the axial section of the third slice were set at the central and peripheral areas of each-the left and the right-lung. T1 relaxation times measured immediately after death differed by the presence or absence of soaking water, except in case of cold water temperature. In the drowning groups, T1 relaxation time showed a linear dependency on water temperature. By contrast, T2 relaxation time was almost constant regardless of the presence of drowning under the same temperature condition; when compared in the lung areas of the same individuals, the times were uniformly reduced in drowning models. To minimize the effects of hypostasis and decomposition, we performed measurements immediately after death and were able to determine the noticeable difference in drowning water temperature. These results may be useful for qualitative assessments of a drowning lung and may serve as a basis when imaging the human body during forensic autopsy cases.


Assuntos
Imagem de Tensor de Difusão , Afogamento/patologia , Patologia Legal/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Mudanças Depois da Morte , Temperatura , Água , Animais , Autopsia , Camundongos Endogâmicos C57BL , Modelos Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...