Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Cardiovasc Imaging ; 21(6): 640-652, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31326995

RESUMO

AIMS: Plaque burden (PB) measurement using intravascular optical coherence tomography (IVOCT) is currently thought to be inferior to intravascular ultrasound (IVUS). We developed an automated IVOCT image processing algorithm to enhance the external elastic lamina (EEL) contour. Thus, we investigated the accuracies of standard IVOCT and an IVOCT enhancement algorithm for measuring PB using IVUS as the reference standard. METHODS AND RESULTS: The EEL-enhancement algorithm combined adaptive attenuation compensation, exponentiation, angular registration, and image averaging using three sequential frames. In two different laboratories with intravascular imaging expertise, PB was quantified on 200 randomized, matched IVOCT and IVUS images by four independent observers. Fibroatheroma, fibrocalcific plaque, fibrous plaque, pathological intimal thickening (PIT), and mixed plaque were included in each set. Pearson's correlation coefficients between IVUS and standard IVOCT measurements of PB were 0.61, 0.67, 0.76, 0.78, and 0.87 for fibroatheromas, mixed plaques, fibrocalcific plaques, fibrous plaques, and PIT plaques, respectively. Pearson's correlation coefficients increased to 0.81, 0.83, 0.83, 0.84, and 0.90 when using the EEL-enhanced images (P = 0.003, P = 0.004, P = 0.08, P = 0.12, and P = 0.23, respectively). EEL-enhanced IVOCT analysis was associated with a lower EEL-area measurement absolute error for fibroatheromas, mixed plaques, and all pooled plaques (P = 0.006, P = 0.02, and P < 0.001, respectively). Compared with standard IVOCT, the EEL-enhanced IVOCT images had a higher sensitivity (79% vs. 28%, P < 0.001) and specificity (98% vs. 85%, P = 0.03) for plaques with an IVUS PB ≥70%. CONCLUSION: EEL-enhanced IVOCT can be used to reliably measure PB in all types of coronary atherosclerotic lesions, including fibroatheromas and mixed plaques.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...