Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Nucl Sci ; 67(1)2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34140746

RESUMO

We used Gaussian separation and receiver operating characteristic (ROC) curves to optimize the neutron sensitivity and gamma rejection of an ultra-thin 6LiF:ZnS(Ag)-scintillator-based neutron detector paired with a silicon photomultiplier (SiPM). We recorded the waveforms while operating the detector in a monochromatic cold neutron beam and in the presence of isotopic 137Cs and 60Co gamma sources. We used a two-window charge comparison (CC) pulse-shape discrimination (PSD) technique to distinguish the neutron capture events from other types of signals. By feeding the recorded waveforms through variants of this algorithm, it was possible to optimize the duration of the integration windows [(0-100 ns) for the prompt window and (100-2300 ns)] for the delayed window. We then computed the detector's ROC curve from waveform recordings and compared that with the experimental performance. We also used this procedure to compare a series of detector configurations to select the optimal bias voltage for the SiPM photosensor.

2.
Appl Radiat Isot ; 151: 317-330, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31376719

RESUMO

A new radio-HPLC detection system for measuring radioactivity in plasma samples during Positron Emission Tomography [PET] studies was developed. It is based on detecting both the positron and one of the annihilation photons. The system focused on improving the measurement of radioactivity concentrations on an unmetabolized positron emitting a radiopharmaceutical [PER] in the presence of its radioactive metabolites, all containing the same positron emitter. This paper presents a new detection configuration that improves the minimal detectible activity (MDA), simplify the measuring systems and reduces the error caused by the metabolites. The detector is based on a plastic scintillator and a BGO scintillation crystal, that produces different light output spectra for signal and noise events. By summing the positron and the annihilated photon light outputs, different spectra are obtained for the metabolite and for the parent compound tracer and for tracer marked by different positron emitting isotopes. This new detection system can improve quantitative analysis of plasma samples. The spectrum change provides up to a three-fold improvement in sensitivity compared to the currently used detection systems that measure only the annihilation coincidence events. Results showed that for 11C the MDA was improved by approximately 520%. Furthermore, it provides the additional advantage of reliability by providing a method for separating the signal and noise readings from the gross detector readout. Accurate reconstruction algorithm of the signal was achieved over a wide measuring range even when the signal was only 5% of the gross measurement.


Assuntos
Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/sangue , Algoritmos , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...