Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; 12(4): e2202021, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36337006

RESUMO

Accurate measurements of skin hydration are of great interest to dermatological science and clinical practice. This parameter serves as a relevant surrogate of skin barrier function, a key representative benchmark for overall skin health. The skin hydration sensor (SHS) is a soft, skin-interfaced wireless system that exploits a thermal measurement method, as an alternative to conventional impedance-based hand-held probes. This study presents multiple strategies for maximizing the sensitivity and reliability of this previously reported SHS platform. An in-depth analysis of the thermal physics of the measurement process serves as the basis for structural optimizations of the electronics and the interface to the skin. Additional engineering advances eliminate variabilities associated with manual use of the device and with protocols for the measurement. The cumulative effect is an improvement in sensitivity by 135% and in repeatability by 36% over previously reported results. Pilot trials on more than 200 patients in a dermatology clinic validate the practical utility of the sensor for fast, reliable measurements.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Reprodutibilidade dos Testes , Pele/química , Eletrônica/métodos , Tecnologia sem Fio
2.
J Reconstr Microsurg ; 39(3): 231-237, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35952677

RESUMO

BACKGROUND: Commercially available near infrared spectroscopy devices for continuous free flap tissue oxygenation (StO2) monitoring can only be used on flaps with a cutaneous component. Additionally, differences in skin quality and pigmentation may alter StO2 measurements. Here, we present a novel implantable heat convection probe that measures microvascular blood flow for peripheral monitoring of free flaps, and is not subject to the same issues that limit the clinical utility of near-infrared spectroscopy. METHODS: The intratissue microvascular flow-sensing device includes a resistive heater, 4 thermistors, a small battery, and a Bluetooth chip, which allows connection to a smart device. Convection of applied heat is measured and mathematically transformed into a measurement of blood flow velocity. This was tested alongside Vioptix T.Ox in a porcine rectus abdominis myocutaneous flap model of arterial and venous occlusion. After flap elevation, the thermal device was deployed intramuscularly, and the cutaneous T.Ox device was applied. Acland clamps were alternately applied to the flap artery and veins to achieve 15 minutes periods of flap ischemia and congestion with a 15 minutes intervening recovery period. In total, five devices were tested in three flaps in three separate pigs over 16 vaso-occlusive events. RESULTS: Flow measurements were responsive to both ischemia and congestion, and returned to baseline during recovery periods. Flow measurements corresponded closely with measured StO2. Cross-correlation at zero lag showed agreement between these two sensing modalities. Two novel devices tested simultaneously on the same flap showed only minor variations in flow measurements. CONCLUSION: This novel probe is capable of detecting changes in tissue microcirculatory blood flow. This device performed well in a swine model of flap ischemia and congestion, and shows promise as a potentially useful clinical tool. Future studies will investigate performance in fasciocutaneous flaps and characterize longevity of the device over a period of several days.


Assuntos
Retalhos de Tecido Biológico , Retalho Miocutâneo , Suínos , Animais , Microcirculação , Retalhos de Tecido Biológico/irrigação sanguínea , Isquemia , Complicações Pós-Operatórias , Artérias
3.
Biosens Bioelectron ; 206: 114145, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35278852

RESUMO

Vascular pedicle thrombosis after free flap transfer or solid organ transplantation surgeries can lead to flap necrosis, organ loss requiring re-transplantation, or even death. Although implantable flow sensors can provide early warning of malperfusion and facilitate operative salvage, measurements performed with existing technologies often depend on extrinsic conditions such as mounting methods and environmental fluctuations. Furthermore, the mechanisms for fixing such probes to vascular or skeletal structures may disrupt the normal blood flow or cause unnecessary tissue damage. Requirements for wired connections to benchtop readout systems also increase costs, complicate clinical care and constrain movements of the patient. Here, we report a wireless, miniaturized flow sensing system that exploits sub-millimeter scale, multi-nodal thermal probes, with biodegradable barbs that secure the probes to the surrounding tissues in a manner that facilitates removal after a period of use. These smartphone-readable devices, together with experimentally validated analytical models of the thermal transport physics, enable reliable, accurate flow sensing in ways that are largely immune to variations in temperature and mechanical perturbations. In vivo demonstrations of this technology in porcine myocutaneous flap and kidney malperfusion models highlight the essential capabilities in microsurgical and transplantation-related biomedical application scenarios.


Assuntos
Técnicas Biossensoriais , Transplantes , Animais , Humanos , Microcirculação , Próteses e Implantes , Suínos
4.
NPJ Digit Med ; 3: 29, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32195364

RESUMO

Hydrocephalus is a common disorder caused by the buildup of cerebrospinal fluid (CSF) in the brain. Treatment typically involves the surgical implantation of a pressure-regulated silicone tube assembly, known as a shunt. Unfortunately, shunts have extremely high failure rates and diagnosing shunt malfunction is challenging due to a combination of vague symptoms and a lack of a convenient means to monitor flow. Here, we introduce a wireless, wearable device that enables precise measurements of CSF flow, continuously or intermittently, in hospitals, laboratories or even in home settings. The technology exploits measurements of thermal transport through near-surface layers of skin to assess flow, with a soft, flexible, and skin-conformal device that can be constructed using commercially available components. Systematic benchtop studies and numerical simulations highlight all of the key considerations. Measurements on 7 patients establish high levels of functionality, with data that reveal time dependent changes in flow associated with positional and inertial effects on the body. Taken together, the results suggest a significant advance in monitoring capabilities for patients with shunted hydrocephalus, with potential for practical use across a range of settings and circumstances, and additional utility for research purposes in studies of CSF hydrodynamics.

5.
ACS Sens ; 5(1): 13-18, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31833351

RESUMO

Environmental hazards typically are encountered in the gaseous phase; however, selective sensing modalities for identifying and quantitating compounds of interest in an inexpensive, pseudo-real-time format are severely lacking. Here, we present a novel proof-of-concept that combines an Air2Liquid sampler in conjunction with an oil-in-water microfluidic assay for detection of organophosphates. We believe this proof-of-concept will enable development of a new platform technology for semivolatile detection that we have demonstrated to detect 50 pmoles (2 ppb) of neurotoxic organophosphates.


Assuntos
Técnicas Biossensoriais/métodos , Gases/química , Organofosfatos/metabolismo
6.
Proc Natl Acad Sci U S A ; 116(43): 21427-21437, 2019 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-31601737

RESUMO

Pharmacology and optogenetics are widely used in neuroscience research to study the central and peripheral nervous systems. While both approaches allow for sophisticated studies of neural circuitry, continued advances are, in part, hampered by technology limitations associated with requirements for physical tethers that connect external equipment to rigid probes inserted into delicate regions of the brain. The results can lead to tissue damage and alterations in behavioral tasks and natural movements, with additional difficulties in use for studies that involve social interactions and/or motions in complex 3-dimensional environments. These disadvantages are particularly pronounced in research that demands combined optogenetic and pharmacological functions in a single experiment. Here, we present a lightweight, wireless, battery-free injectable microsystem that combines soft microfluidic and microscale inorganic light-emitting diode probes for programmable pharmacology and optogenetics, designed to offer the features of drug refillability and adjustable flow rates, together with programmable control over the temporal profiles. The technology has potential for large-scale manufacturing and broad distribution to the neuroscience community, with capabilities in targeting specific neuronal populations in freely moving animals. In addition, the same platform can easily be adapted for a wide range of other types of passive or active electronic functions, including electrical stimulation.


Assuntos
Optogenética/métodos , Farmacologia/métodos , Animais , Encéfalo/metabolismo , Química Encefálica , Channelrhodopsins/metabolismo , Estimulação Elétrica , Feminino , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Optogenética/instrumentação , Farmacologia/instrumentação , Próteses e Implantes , Tecnologia sem Fio/instrumentação
7.
Lab Chip ; 19(9): 1545-1555, 2019 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-30912557

RESUMO

The rich range of biomarkers in sweat and the ability to collect sweat in a non-invasive manner create interest in the use of this biofluid for assessments of health and physiological status, with potential applications that range from sports and fitness to clinical medicine. This paper introduces two important advances in recently reported classes of soft, skin-interfaced microfluidic systems for sweat capture and analysis: (1) a simple, broadly applicable means for collection of sweat that bypasses requirements for physical/mental exertion or pharmacological stimulation and (2) a set of enzymatic chemistries and colorimetric readout approaches for determining the concentrations of creatinine and urea in sweat, throughout ranges that are physiologically relevant. The results allow for routine, non-pharmacological capture of sweat for patient populations, such as infants and the elderly, that cannot be expected to sweat through exercise, and they create potential opportunities in the use of sweat for kidney disease screening/monitoring. Studies on human subjects demonstrate these essential capabilities, with quantitative comparisons to standard methods. The results expand the range of options available in microfluidic sampling and sensing of sweat for disease diagnostics and health monitoring.


Assuntos
Colorimetria/instrumentação , Nefropatias/metabolismo , Dispositivos Lab-On-A-Chip , Suor/metabolismo , Biomarcadores/metabolismo , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...