Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 97(1160): 1492-1500, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38917414

RESUMO

OBJECTIVES: To investigate the usefulness of super-resolution deep learning reconstruction (SR-DLR) with cardiac option in the assessment of image quality in patients with stent-assisted coil embolization, coil embolization, and flow-diverting stent placement compared with other image reconstructions. METHODS: This single-centre retrospective study included 50 patients (mean age, 59 years; range, 44-81 years; 13 men) who were treated with stent-assisted coil embolization, coil embolization, and flow-diverting stent placement between January and July 2023. The images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR), and SR-DLR. The objective image analysis included image noise in the Hounsfield unit (HU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and full width at half maximum (FWHM). Subjectively, two radiologists evaluated the overall image quality for the visualization of the flow-diverting stent, coil, and stent. RESULTS: The image noise in HU in SR-DLR was 6.99 ± 1.49, which was significantly lower than that in images reconstructed with FBP (12.32 ± 3.01) and hybrid IR (8.63 ± 2.12) (P < .001). Both the mean SNR and CNR were significantly higher in SR-DLR than in FBP and hybrid IR (P < .001 and P < .001). The FWHMs for the stent (P < .004), flow-diverting stent (P < .001), and coil (P < .001) were significantly lower in SR-DLR than in FBP and hybrid IR. The subjective visual scores were significantly higher in SR-DLR than in other image reconstructions (P < .001). CONCLUSIONS: SR-DLR with cardiac option is useful for follow-up imaging in stent-assisted coil embolization and flow-diverting stent placement in terms of lower image noise, higher SNR and CNR, superior subjective image analysis, and less blooming artifact than other image reconstructions. ADVANCES IN KNOWLEDGE: SR-DLR with cardiac option allows better visualization of the peripheral and smaller cerebral arteries. SR-DLR with cardiac option can be beneficial for CT imaging of stent-assisted coil embolization and flow-diverting stent.


Assuntos
Aprendizado Profundo , Procedimentos Endovasculares , Aneurisma Intracraniano , Stents , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Estudos Retrospectivos , Adulto , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/métodos , Embolização Terapêutica/métodos , Razão Sinal-Ruído
2.
Br J Radiol ; 97(1159): 1286-1294, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38733576

RESUMO

OBJECTIVES: This study aimed to assess the impact of super-resolution deep learning reconstruction (SR-DLR) on coronary CT angiography (CCTA) image quality and blooming artifacts from coronary artery stents in comparison to conventional methods, including hybrid iterative reconstruction (HIR) and deep learning-based reconstruction (DLR). METHODS: A retrospective analysis included 66 CCTA patients from July to November 2022. Major coronary arteries were evaluated for image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Stent sharpness was quantified using 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD). Qualitative analysis employed a 5-point scoring system to assess overall image quality, image noise, vessel wall, and stent structure. RESULTS: SR-DLR demonstrated significantly lower image noise compared to HIR and DLR. SNR and CNR were notably higher in SR-DLR. Stent ERS was significantly improved in SR-DLR, with mean ERD values of 0.70 ± 0.20 mm for SR-DLR, 1.13 ± 0.28 mm for HIR, and 0.85 ± 0.26 mm for DLR. Qualitatively, SR-DLR scored higher in all categories. CONCLUSIONS: SR-DLR produces images with lower image noise, leading to improved overall image quality, compared with HIR and DLR. SR-DLR is a valuable image reconstruction algorithm for enhancing the spatial resolution and sharpness of coronary artery stents without being constrained by hardware limitations. ADVANCES IN KNOWLEDGE: The overall image quality was significantly higher in SR-DLR, resulting in sharper coronary artery stents compared to HIR and DLR.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Aprendizado Profundo , Razão Sinal-Ruído , Stents , Humanos , Estudos Retrospectivos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Vasos Coronários/diagnóstico por imagem , Artefatos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38806237

RESUMO

BACKGROUND AND PURPOSE: The cerebral metabolic rate of oxygen (CMRO2) is considered a robust marker of the infarct core in 15°-tracer- based positron emission tomography. We aimed to delineate the infarct core in patients with acute ischemic stroke using commonly used relative cerebral blood flow (rCBF) < 30% and oxygen metabolism parameter of CMRO2 on CT perfusion in comparison with pre-treatment diffusion- weighted imaging (DWI)-derived infarct core volume. MATERIALS AND METHODS: Patients with acute ischemic stroke who met the inclusion criteria were recruited. The CMRO2 and CBF maps in CT perfusion were automatically generated using post-processing software. The infarct core volume was quantified with relative (r) CMRO2 < 20% - 30% and rCBF < 30%. The optimal threshold was defined as those that demonstrated the smallest mean absolute error, lowest mean infarct core volume difference, narrowest 95% limit of agreement, and largest intraclass correlation coefficient (ICC) against the DWI. RESULTS: This study included 76 patients (mean age ± standard deviation, 69.97 ± 12.15 years, 43 males). The optimal thresholds of rCMRO2 < 26% resulted in the lowest mean infarct core volume difference, narrowest 95% limit of agreement, and largest ICC among different thresholds. Bland-Altman analysis demonstrated a volumetric bias of 1.96 mL between DWI and rCMRO2 < 26%, whereas in cases of DWI and rCBF < 30%, the bias was notably larger at 14.10 mL. The highest correlation was observed for rCMRO2 < 26% (ICC=0.936), whereas rCBF < 30% showed a slightly lower ICC of 0.934. CONCLUSIONS: CT perfusion-derived CMRO2 is a promising parameter for estimating the infarct core volume in patients with acute ischemic stroke. ABBREVIATIONS: CMRO2 = cerebral metabolic rate of oxygen.

4.
Tomography ; 10(3): 368-377, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38535771

RESUMO

(1) Background: The intravoxel incoherent motion (IVIM) model can provide information about both molecular diffusion and blood flow for the evaluation of skeletal muscle inflammation. MRI-based fat quantification is advantageous for assessing fat infiltration in skeletal muscle. (2) Purpose: We aimed to quantitatively measure various parameters associated with IVIM diffusion-weighted imaging (DWI) and fat quantification in the muscles of patients with polymyositis and dermatomyositis using magnetic resonance imaging and to investigate the relationship between these parameters and electromyography (EMG) findings. (3) Material and methods: Data were retrospectively evaluated for 12 patients with polymyositis and dermatomyositis who underwent thigh MRI, including IVIM-DWI and fat quantification. The IVIM-derived parameters included the pure diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f). Fat fraction values were assessed using the six-point Dixon technique. Needle EMG was performed within 9 days of the MRI. (4) Results: The f values (19.02 ± 4.87%) in muscles with pathological spontaneous activity on EMG were significantly higher than those (14.60 ± 5.31) in muscles without pathological spontaneous activity (p < 0.027). There were no significant differences in D, D*, ADC, or fat fraction between muscles with and without pathologic spontaneous activity. Significant negative correlations were observed between fat fraction and amplitude (r = -0.402, p < 0.015) and between fat fraction and duration (r = -0.360, p < 0.031). (5) Conclusion: The current study demonstrates that IVIM-DWI and fat quantification using 3.0 T MRI may aid in predicting EMG findings in patients with polymyositis and dermatomyositis and promote the pathophysiological study of idiopathic inflammatory myopathies.


Assuntos
Dermatomiosite , Miosite , Polimiosite , Humanos , Eletromiografia , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética
5.
Diagnostics (Basel) ; 13(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37296714

RESUMO

BACKGROUND: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients. OBJECTIVE: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR). METHODS: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR. RESULTS: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR. CONCLUSION: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.

6.
Acta Radiol ; 64(8): 2393-2400, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37211615

RESUMO

BACKGROUND: The reference protocol for the quantification of coronary artery calcium (CAC) should be updated to meet the standards of modern imaging techniques. PURPOSE: To assess the influence of filtered-back projection (FBP), hybrid iterative reconstruction (IR), and three levels of deep learning reconstruction (DLR) on CAC quantification on both in vitro and in vivo studies. MATERIAL AND METHODS: In vitro study was performed with a multipurpose anthropomorphic chest phantom and small pieces of bones. The real volume of each piece was measured using the water displacement method. In the in vivo study, 100 patients (84 men; mean age = 71.2 ± 8.7 years) underwent CAC scoring with a tube voltage of 120 kVp and image thickness of 3 mm. The image reconstruction was done with FBP, hybrid IR, and three levels of DLR including mild (DLRmild), standard (DLRstd), and strong (DLRstr). RESULTS: In the in vitro study, the calcium volume was equivalent (P = 0.949) among FBP, hybrid IR, DLRmild, DLRstd, and DLRstr. In the in vivo study, the image noise was significantly lower in images that used DLRstr-based reconstruction, when compared images other reconstructions (P < 0.001). There were no significant differences in the calcium volume (P = 0.987) and Agatston score (P = 0.991) among FBP, hybrid IR, DLRmild, DLRstd, and DLRstr. The highest overall agreement of Agatston scores was found in the DLR groups (98%) and hybrid IR (95%) when compared to standard FBP reconstruction. CONCLUSION: The DLRstr presented the lowest bias of agreement in the Agatston scores and is recommended for the accurate quantification of CAC.


Assuntos
Doença da Artéria Coronariana , Interpretação de Imagem Radiográfica Assistida por Computador , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Algoritmos , Cálcio , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Aprendizado Profundo , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Feminino
7.
PLoS One ; 18(4): e0284793, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37079597

RESUMO

BACKGROUND AND PURPOSE: This study aimed to investigate the potential of contrast enhancement (CE)-boost technique in the head and neck computed tomography (CT) angiography in terms of the objective and subjective image quality. MATERIALS AND METHODS: Consecutive patients who underwent head and neck CT angiography between May 2022 and July 2022 were included. The CE-boost images were generated by combining the subtracted iodinated image and contrast-enhanced image. The objective image analysis was compared for each image with and without CE-boost technique using the CT attenuation, image noise, signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), and image sharpness (full width at half width maximum, FWHM). The subjective image analysis was evaluated by two independent experienced radiologists in the following aspects: the overall image quality, motion artifact, vascular delineation, and vessel sharpness. RESULTS: A total of 65 patients (mean age, 59.48 ± 13.71 years; range, 24-87 years; 36 women) were included. The CT attenuation of the vertebrobasilar arteries was significantly (p < 0.001) higher in the images obtained using CE-boost technique than in conventional images. Image noise was significantly (p < 0.001) lower for CE-boost images (6.09 ± 1.93) than for conventional images (7.79 ± 1.73). Moreover, CE-boost technique yielded higher SNR (64.43 ± 17.17 vs. 121.37 ± 38.77, p < 0.001) and CNR (56.90 ± 18.79 vs. 116.65 ± 57.44, p < 0.001) than conventional images. CE-boost resulted in shorter FWHM than conventional images (p < 0.001). Higher subjective image quality scores were also demonstrated by the CE-boost than images without CE-boost technique. CONCLUSIONS: In both objective and subjective image analysis, the CE-boost technique provided higher image quality without increasing the flow rate and concentration of contrast media in the head and neck CT angiography. Furthermore, the vessel completeness and delineation were superior in CE-boost images than in conventional images.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem , Razão Sinal-Ruído , Angiografia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
8.
J Stroke Cerebrovasc Dis ; 32(6): 107062, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36948076

RESUMO

OBJECTIVE: Although computed tomography perfusion (CTP) is used to select and guide decision-making processes in patients with acute ischemic stroke, there is no clear standardization of the optimal threshold to predict ischemic core volume accurately. The infarct core volume with a relative cerebral blood flow(rCBF) threshold of < 30% is commonly used. We aimed to assess the volumetric agreement of the infarct core volume with different CTP parameters and thresholds using CTP software (RAPID, VITREA) and the infarct volume on diffusion-weighted imaging (DWI), with a short interval time (within 60 min) between CTP and follow-up DWI. MATERIALS AND METHODS: This retrospective study included 42 acute ischemic stroke patients with occlusion of the large artery in the anterior circulation between April 2017-November 2020. RAPID identified infarct core as tissue rCBF < 20-38%. VITREA defined the infarct core as cerebral blood volume (CBV) < 26-56%. Olea Sphere was used to measure infarct core volume on DWI. The CTP-infarct core volume with different thresholds of perfusion parameters (CBF threshold vs CBV threshold) were compared with DWI-infarct core volumes. RESULTS: The median time between CTP and DWI was 37.5min. The commonly used threshold of CBV< 41% (4.3 mL) resulted in lower median infarct core volume difference compared to the commonly used thresholds of rCBF < 30% (8.2mL). On the other hand, the optimal thresholds of CBV < 26% (-1.0mL; 95% CI, -53.9 to 58.1 mL; 0.945) resulted in the lowest median infarct core volume difference, narrowest limits of agreement, and largest interclass correlation coefficient compared with the optimal thresholds of rCBF < 38% (4.9 mL; 95% CI, -36.4 to 62.9 mL; 0.939). CONCLUSION: Our study found that the both optimal and commonly used thresholds of CBV provided a more accurate prediction of the infarct core volume in patients with AIS than rCBF.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Perfusão , Circulação Cerebrovascular , Infarto , Imagem de Perfusão/métodos , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia
9.
Acta Radiol ; 64(3): 1007-1017, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35979586

RESUMO

BACKGROUND: The demand for homogeneous and higher vascular contrast enhancement is critical to provide an appropriate interpretation of abnormal vascular findings in coronary computed tomography angiography (CTA). PURPOSE: To evaluate the effect of various contrast media concentrations (Iohexol-370, Iohexol-300, Iohexol-240) and image reconstructions (filtered back projection [FBP], hybrid iterative reconstruction [IR], and deep learning reconstruction [DLR]) on coronary CTA. MATERIAL AND METHODS: A total of 63 patients referred for coronary CTA between July and October 2021 were enrolled in this prospective study, and they randomly received one of three contrast media. CTA images were reconstructed with FBP, hybrid IR, and DLR. The CT attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for all three images. The images were subjectively evaluated by two radiologists in terms of overall image quality, artifacts, image noise, and vessel wall delineation on a 5-point Likert scale. RESULTS: The application of DLR resulted in significantly lower image noise; higher CT attenuation, SNR, and CNR; and better subjective analysis among the three different concentrations of contrast media groups (P < 0.001). There was no significant difference in the CT attenuation of the left ventricle (P = 0.089) and coronary arteries (P = 0.072) between hybrid IR at Iohexol-300 and DLR at Iohexol-240. Furthermore, application of DLR to the Iohexol-240 significantly improved SNR and CNR; it achieved higher subjective scores compared with hybrid IR at Iohexol-300 (P < 0.001). CONCLUSION: We suggest that using DLR with Iohexol-240 contrast media is preferable to hybrid IR with Iohexol-300 contrast media in coronary CTA.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Humanos , Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Angiografia Coronária/métodos , Vasos Coronários , Iohexol , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
10.
Korean J Radiol ; 23(11): 1044-1054, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36196766

RESUMO

OBJECTIVE: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. MATERIALS AND METHODS: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. RESULTS: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. CONCLUSION: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Humanos , Masculino , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Algoritmos , Doses de Radiação , Angiografia Coronária/métodos
11.
J Comput Assist Tomogr ; 46(5): 729-734, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36103677

RESUMO

OBJECTIVE: This study aimed to evaluate chest computed tomography (CT) angiography image quality using the contrast enhancement (CE)-boost technique compared with conventional images. METHODS: Forty patients who underwent contrast-enhanced chest CT were included. Combined CT angiography images of the iodinated image obtained from the subtraction of nonenhanced CT images and CT angiography images were used to generate CE-boost images. Computed tomography attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for the right and left pulmonary arteries as the central and subsegmental arteries as peripheral vessels were assessed. Subjective image quality was rated on a 5-point scale by 2 radiologists. Image quality was assessed using a paired t test. RESULTS: Computed tomography attenuation in the main pulmonary artery was significantly higher for the CE-boost images (311.05 ± 91.94) than for the conventional images (221.25 ± 61.21, P < 0.001). Similarly, the CE-boost images resulted in significantly higher CT attenuation in the subsegmental arteries (right, 305.34 ± 90.13; left, 313.05 ± 97.21) than in the conventional images (right, 218.45 ± 63.16; left, 223.89 ± 74.27). The CE-boost technique demonstrated marked improvement in the visualization of the peripheral pulmonary artery without the administration of a higher iodine delivery rate. The mean SNR and CNR were also significantly higher in the central and peripheral vessels in the CE-boost images than in the conventional images (P < 0.001). In the subjective analysis, the image contrast and vascular contrast edge were significantly higher for the CE-boost images than for conventional images (P < 0.001). CONCLUSIONS: The CE-boost technique increases not only the visualization of peripheral arteries by improving vascular attenuation but also the SNR and CNR.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Angiografia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
12.
J Integr Neurosci ; 20(4): 967-976, 2021 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-34997719

RESUMO

To evaluate the ability of a commercialized deep learning reconstruction technique to depict intracranial vessels on the brain computed tomography angiography and compare the image quality with filtered-back-projection and hybrid iterative reconstruction in terms of objective and subjective measures. Forty-three patients underwent brain computed tomography angiography, and images were reconstructed using three algorithms: filtered-back-projection, hybrid iterative reconstruction, and deep learning reconstruction. The image noise, computed tomography attenuation value, signal-to-noise ratio, and contrast-to-noise ratio were measured in the bilateral cavernous segment of the internal carotid artery, vertebral artery, basilar apex, horizontal segment of the middle cerebral artery and used for the objective assessment of the image quality among the three different reconstructions. The subjective image quality score was significantly higher for the deep learning reconstruction than hybrid iterative reconstruction and filtered-back-projection images. The deep learning reconstruction markedly improved the reduction of blooming artifacts in surgical clips and coiled aneurysms. The deep learning reconstruction method generally improves the image quality of brain computed tomography angiography in terms of objective measurement and subjective grading compared with filtered-back-projection and hybrid iterative reconstruction. Especially, deep learning reconstruction is deemed advantageous for better depiction of small vessels compared to filtered-back projection and hybrid iterative reconstruction.


Assuntos
Artérias Cerebrais/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/normas , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/diagnóstico por imagem , Estudos Retrospectivos , Artéria Vertebral/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...