Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Infect Dis ; 21(1): 937, 2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34503469

RESUMO

BACKGROUND: Malaria and schistosomiasis present considerable disease burden in tropical and sub-tropical areas and severity is worsened by co-infections in areas where both diseases are endemic. Although pathogenesis of these infections separately is well studied, there is limited information on the pathogenic disease mechanisms and clinical disease outcomes in co-infections. In this study, we investigated the prevalence of malaria and schistosomiasis co-infections, and the hematologic and blood chemistry abnormalities in asymptomatic adults in a rural fishing community in western Kenya. METHODS: This sub-study used samples and data collected at enrollment from a prospective observational cohort study (RV393) conducted in Kisumu County, Kenya. The presence of malaria parasites was determined using microscopy and real-time-PCR, and schistosomiasis infection by urine antigen analysis (CCA). Hematological analysis and blood chemistries were performed using standard methods. Statistical analyses were performed to compare demographic and infection data distribution, and hematologic and blood chemistry parameters based on different groups of infection categories. Clinically relevant hematologic conditions were analyzed using general linear and multivariable Poisson regression models. RESULTS: From February 2017 to May 2018, we enrolled 671 participants. The prevalence of asymptomatic Plasmodium falciparum was 28.2% (157/556) and schistosomiasis 41.2% (229/562), with 18.0% (100/556) of participants co-infected. When we analyzed hematological parameters using Wilcoxon rank sum test to evaluate median (IQR) distribution based on malarial parasites and/or schistosomiasis infection status, there were significant differences in platelet counts (p = 0.0002), percent neutrophils, monocytes, eosinophils, and basophils (p < 0.0001 each). Amongst clinically relevant hematological abnormalities, eosinophilia was the most prevalent at 20.6% (116/562), whereas thrombocytopenia was the least prevalent at 4.3% (24/562). In univariate model, Chi-Square test performed for independence between participant distribution in different malaria parasitemia/schistosomiasis infection categories within each clinical hematological condition revealed significant differences for thrombocytopenia and eosinophilia (p = 0.006 and p < 0.0001, respectively), which was confirmed in multivariable models. Analysis of the pairwise mean differences of liver enzyme (ALT) and kidney function (Creatinine Clearance) indicated the presence of significant differences in ALT across the infection groups (parasite + /CCA + vs all other groups p < .003), but no differences in mean Creatinine Clearance across the infection groups. CONCLUSIONS: Our study demonstrates the high burden of asymptomatic malaria parasitemia and schistosomiasis infection in this rural population in Western Kenya. Asymptomatic infection with malaria or schistosomiasis was associated with laboratory abnormalities including neutropenia, leukopenia and thrombocytopenia. These abnormalities could be erroneously attributed to other diseases processes during evaluation of diseases processes. Therefore, evaluating for co-infections is key when assessing individuals with laboratory abnormalities. Additionally, asymptomatic infection needs to be considered in control and elimination programs given high prevalence documented here.


Assuntos
Coinfecção , Malária Falciparum , Malária , Esquistossomose , Adulto , Infecções Assintomáticas/epidemiologia , Coinfecção/epidemiologia , Estudos Transversais , Humanos , Quênia/epidemiologia , Malária/complicações , Malária/epidemiologia , Malária Falciparum/complicações , Malária Falciparum/epidemiologia , Plasmodium falciparum , Prevalência , Estudos Prospectivos , População Rural , Esquistossomose/complicações , Esquistossomose/epidemiologia
2.
J Health Pollut ; 9(21): 190307, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30931167

RESUMO

BACKGROUND: The informal settlement of Owino Uhuru near an abandoned lead smelter attracted international attention due to an apparent lead poisoning event. Despite this attention, the environmental data collected to date do not indicate high levels of residual contamination. OBJECTIVES: To further confirm previous findings and determine any necessary risk mitigation measures, an assessment of surface soil lead concentrations was conducted in the community. METHODS: Investigators carried out an assessment of the soil in a ~12,000 m2 section of the Owino Uhuru neighborhood over the course of a single day in June 2017 with the assistance of community leaders. Fifty-nine in situ soil measurements were taken using an Innov-X tube-based (40 kV) alpha X-ray fluorescence instrument (pXRF). RESULTS: The assessment found that mean surface soil lead concentrations in areas conducive to exposure were 110 mg/kg (95% CI: 54-168); below United States Environmental Protection Agency and the Environment Canada screening levels of 400 mg/kg and 140 mg/kg, respectively. CONCLUSIONS: There is likely no current need for risk mitigation activities in the community. These results could inform discussions on the allocation of public health spending. COMPETING INTERESTS: The authors declare no competing financial interests. BE, VOO, CN and JSF are employees of Pure Earth. MPT sits on the Editorial Board of the Journal of Health and Pollution.

3.
Malar J ; 16(1): 221, 2017 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-28545579

RESUMO

BACKGROUND: One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. METHODS: From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. RESULTS: Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. CONCLUSIONS: Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.


Assuntos
Testes Diagnósticos de Rotina/métodos , Laboratórios/estatística & dados numéricos , Malária/diagnóstico , Microscopia/métodos , Controle de Qualidade , Instalações de Saúde/estatística & dados numéricos , Humanos , Quênia , Projetos Piloto , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...