1.
Micromachines (Basel) ; 15(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38399008

RESUMO

Compound nerve action potentials (CNAPs) were used as a metric to assess the stimulation performance of a novel high-density, transverse, intrafascicular electrode in rat models. We show characteristic CNAPs recorded from distally implanted cuff electrodes. Evaluation of the CNAPs as a function of stimulus current and calculation of recruitment plots were used to obtain a qualitative approximation of the neural interface's placement and orientation inside the nerve. This method avoids elaborate surgeries required for the implantation of EMG electrodes and thus minimizes surgical complications and may accelerate the healing process of the implanted subject.

2.
Physiol Genomics ; 55(12): 606-617, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37746712

RESUMO

Augmented vagal signaling may be therapeutic in hypertension. Most studies to date have used stimulation of the cervical vagal branches. Here, we investigated the effects of chronic intermittent electric stimulation of the ventral subdiaphragmatic vagal nerve branch (sdVNS) on long-term blood pressure, immune markers, and gut microbiota in the spontaneously hypertensive rat (SHR), a rodent model of hypertension characterized by vagal dysfunction, gut dysbiosis, and low-grade inflammation. We evaluated the effects of sdVNS on transcriptional networks in the nucleus of the solitary tract (NTS), a major cardioregulatory brain region with direct gut vagal projections. Male juvenile SHRs were implanted with radiotelemetry transmitters and vagal nerve cuffs for chronic intermittent electric sdVNS, applied three times per day for 7 consecutive weeks followed by 1 wk of no stimulation. Blood pressure was measured once a week using telemetry in the sdVNS group as well as age-matched sham-stimulated SHR controls. At the endpoint, colonic and circulating inflammatory markers, corticosterone, and circulating catecholamines were investigated. Bacterial 16 s sequencing measured gut bacterial abundance and composition. RNA sequencing evaluated the effects of sdVNS on transcriptional networks in the NTS. SHRs that received sdVNS exhibited attenuated development of hypertension compared with sham animals. No changes in peripheral inflammatory markers, corticosterone, or catecholamines and no major differences in gut bacterial diversity and composition were observed following sdVNS, apart from decreased abundance of Defluviitaleaceale bacterium detected in sdVNS SHRs compared with sham animals. RNA sequencing revealed significant sdVNS-dependent modulation of select NTS transcriptional networks, including catecholaminergic and corticosteroid networks.NEW & NOTEWORTHY We show that stimulation of the ventral subdiaphragmatic vagal nerve branch may be a promising potential approach to treating hypertension. The data are especially encouraging given that rodents received only 30 min per day of intermittent stimulation therapy and in view of the potential of long-term blood pressure effects that are not stimulus-locked.


Assuntos
Hipertensão , Estimulação do Nervo Vago , Ratos , Animais , Masculino , Ratos Endogâmicos SHR , Núcleo Solitário , Redes Reguladoras de Genes , Corticosterona , Hipertensão/genética , Hipertensão/terapia , Catecolaminas
3.
Front Neurosci ; 17: 1179276, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37397461

RESUMO

During type 1 diabetes, an autoimmune attack destroys pancreatic ß-cells leading to the inability to maintain glucose homeostasis. These ß-cells are neuroresponsive endocrine cells which normally secrete insulin partially in response to input from the vagus nerve. This neural pathway can be utilized as a point of therapeutic intervention by delivering exogenous stimulation to drive increased insulin secretion. In this study, a cuff electrode was implanted on the pancreatic branch of the vagus nerve just prior to pancreatic insertion in rats, and a continuous glucose meter was implanted into the descending aorta. Streptozotocin (STZ) was used to induce a diabetic state, and changes in blood glucose were assessed using various stimulation parameters. Stimulation driven changes in hormone secretion, pancreatic blood flow, and islet cell populations were assessed. We found increased changes in the rate of blood glucose change during stimulation which subsided after stimulation ended paired with increased concentration of circulating insulin. We did not observe increased pancreatic perfusion, which suggests that the modulation of blood glucose was due to the activation of b-cells rather than changes in the extra-organ transport of insulin. Pancreatic neuromodulation showed potentially protective effects by reducing deficits in islet diameter, and ameliorating insulin loss after STZ treatment.

4.
Bioelectron Med ; 9(1): 15, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37434246

RESUMO

BACKGROUND: The purpose of this study was to evaluate if kilohertz frequency alternating current (KHFAC) stimulation of peripheral nerve could serve as a treatment for lumbar radiculopathy. Prior work shows that KHFAC stimulation can treat sciatica resulting from chronic sciatic nerve constriction. Here, we evaluate if KHFAC stimulation is also beneficial in a more physiologic model of low back pain which mimics nucleus pulposus (NP) impingement of a lumbar dorsal root ganglion (DRG). METHODS: To mimic a lumbar radiculopathy, autologous tail NP was harvested and placed upon the right L5 nerve root and DRG. During the same surgery, a cuff electrode was implanted around the sciatic nerve with wires routed to a headcap for delivery of KHFAC stimulation. Male Lewis rats (3 mo., n = 18) were separated into 3 groups: NP injury + KHFAC stimulation (n = 7), NP injury + sham cuff (n = 6), and sham injury + sham cuff (n = 5). Prior to surgery and for 2 weeks following surgery, animal tactile sensitivity, gait, and static weight bearing were evaluated. RESULTS: KHFAC stimulation of the sciatic nerve decreased behavioral evidence of pain and disability. Without KHFAC stimulation, injured animals had heightened tactile sensitivity compared to baseline (p < 0.05), with tactile allodynia reversed during KHFAC stimulation (p < 0.01). Midfoot flexion during locomotion was decreased after injury but improved with KHFAC stimulation (p < 0.05). Animals also placed more weight on their injured limb when KHFAC stimulation was applied (p < 0.05). Electrophysiology measurements at end point showed decreased, but not blocked, compound nerve action potentials with KHFAC stimulation (p < 0.05). CONCLUSIONS: KHFAC stimulation decreases hypersensitivity but does not cause additional gait compensations. This supports the idea that KHFAC stimulation applied to a peripheral nerve may be able to treat chronic pain resulting from sciatic nerve root inflammation.

5.
Front Neurosci ; 17: 1096097, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37090803

RESUMO

Intracortical recordings can be used to voluntarily control external devices via brain-machine interfaces (BMI). Multiple factors, including the foreign body response (FBR), limit the stability of these neural signals over time. Current clinically approved devices consist of multi-electrode arrays with a single electrode site at the tip of each shank, confining the recording interface to a single layer of the cortex. Advancements in manufacturing technology have led to the development of high-density electrodes that can record from multiple layers. However, the long-term stability of neural recordings and the extent of neuronal cell loss around the electrode across different cortical depths have yet to be explored. To answer these questions, we recorded neural signals from rats chronically implanted with a silicon-substrate microelectrode array spanning the layers of the cortex. Our results show the long-term stability of intracortical recordings varies across cortical depth, with electrode sites around L4-L5 having the highest stability. Using machine learning guided segmentation, our novel histological technique, DeepHisto, revealed that the extent of neuronal cell loss varies across cortical layers, with L2/3 and L4 electrodes having the largest area of neuronal cell loss. These findings suggest that interfacing depth plays a major role in the FBR and long-term performance of intracortical neuroprostheses.

6.
Curr Rheumatol Rep ; 25(1): 1-11, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36435890

RESUMO

PURPOSE OF REVIEW: The following review discusses the therapeutic potential of targeting the autonomic nervous system (ANS) for osteoarthritis (OA) treatment and encourages the field to consider the candidacy of bioelectronic medicine as a novel OA treatment strategy. RECENT FINDINGS: The study of OA pathogenesis has focused on changes occurring at the joint level. As such, treatments for OA have been aimed at the local joint environment, intending to resolve local inflammation and decrease pain. However, OA pathogenesis has shown to be more than joint wear and tear. Specifically, OA-related peripheral and central sensitization can prompt neuroplastic changes in the nervous system beyond the articular joint. These neuroplastic changes may alter physiologic systems, like the neuroimmune axis. In this way, OA and related comorbidities may share roots in the form of altered neuroimmune communication and autonomic dysfunction. ANS modulation may be able to modify OA pathogenesis or reduce the impact of OA comorbidities. Moreover, blocking chronic nociceptive drive from the joint may help to prevent maladaptive nervous system plasticity in OA.


Assuntos
Osteoartrite , Humanos , Osteoartrite/terapia , Dor , Inflamação
7.
J Neural Eng ; 19(5)2022 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-35998559

RESUMO

Objective. Although neural-enabled prostheses have been used to restore some lost functionality in clinical trials, they have faced difficulty in achieving high degree of freedom, natural use compared to healthy limbs. This study investigated thein vivofunctionality of a flexible and scalable regenerative peripheral-nerve interface suspended within a microchannel-embedded, tissue-engineered hydrogel (the magnetically aligned regenerative tissue-engineered electronic nerve interface (MARTEENI)) as a potential approach to improving current issues in peripheral nerve interfaces.Approach. Assembled MARTEENI devices were implanted in the gaps of severed sciatic nerves in Lewis rats. Both acute and chronic electrophysiology were recorded, and channel-isolated activity was examined. In terminal experiments, evoked activity during paw compression and stimulus response curves generated from proximal nerve stimulation were examined. Electrochemical impedance spectroscopy was performed to assess the complex impedance of recording sites during chronic data collection. Features of the foreign-body response (FBR) in non-functional implants were examined using immunohistological methods.Main results. Channel-isolated activity was observed in acute, chronic, and terminal experiments and showed a typically biphasic morphology with peak-to-peak amplitudes varying between 50 and 500µV. For chronic experiments, electrophysiology was observed for 77 days post-implant. Within the templated hydrogel, regenerating axons formed minifascicles that varied in both size and axon count and were also found to surround device threads. No axons were found to penetrate the FBR. Together these results suggest the MARTEENI is a promising approach for interfacing with peripheral nerves.Significance. Findings demonstrate a high likelihood that observed electrophysiological activity recorded from implanted MARTEENIs originated from neural tissue. The variation in minifascicle size seen histologically suggests that amplitude distributions observed in functional MARTEENIs may be due to a combination of individual axon and mini-compound action potentials. This study provided an assessment of a functional MARTEENI in anin vivoanimal model for the first time.


Assuntos
Nervos Periféricos , Nervo Isquiático , Animais , Axônios/fisiologia , Eletrônica , Hidrogéis , Regeneração Nervosa/fisiologia , Nervos Periféricos/fisiologia , Ratos , Ratos Endogâmicos Lew , Nervo Isquiático/fisiologia
8.
Front Neurosci ; 16: 876142, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35784835

RESUMO

Intracortical microstimulation (ICMS) has shown promise in restoring quality of life to patients suffering from paralysis, specifically when used in the primary somatosensory cortex (S1). However, these benefits can be hampered by long-term degradation of electrode performance due to the brain's foreign body response. Advances in microfabrication techniques have allowed for the development of neuroprostheses with subcellular electrodes, which are characterized by greater versatility and a less detrimental immune response during chronic use. These probes are hypothesized to enable more selective, higher-resolution stimulation of cortical tissue with long-term implants. However, microstimulation using physiologically relevant charges with these smaller-scale devices can damage electrode sites and reduce the efficacy of the overall device. Studies have shown promise in bypassing this limitation by spreading the stimulation charge between multiple channels in an implanted electrode array, but to our knowledge the usefulness of this strategy in laminar arrays with electrode sites spanning each layer of the cortex remains unexplored. To investigate the efficacy of simultaneous multi-channel ICMS in electrode arrays with stimulation sites spanning cortical depth, we implanted laminar electrode arrays in the primary somatosensory cortex of rats trained in a behavioral avoidance paradigm. By measuring detection thresholds, we were able to quantify improvements in ICMS performance using a simultaneous multi-channel stimulation paradigm. The charge required per site to elicit detection thresholds was halved when stimulating from two adjacent electrode sites, although the overall charge used by the implant was increased. This reduction in threshold charge was more pronounced when stimulating with more than two channels and lessened with greater distance between stimulating channels. Our findings suggest that these improvements are based on the synchronicity and polarity of each stimulus, leading us to conclude that these improvements in stimulation efficiency per electrode are due to charge summation as opposed to a summation of neural responses to stimulation. Additionally, the per-site charge reductions are seen regardless of the cortical depth of each utilized channel. This evocation of physiological detection thresholds with lower stimulation currents per electrode site has implications for the feasibility of stimulation regimes in future advanced neuroprosthetic devices, which could benefit from reducing the charge output per site.

9.
Front Neurosci ; 16: 908858, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35769707

RESUMO

Intracortical microstimulation (ICMS) of the somatosensory cortex (S1) can restore sensory function in patients with paralysis. Studies assessing the stability of ICMS have reported heterogeneous responses across electrodes and over time, potentially hindering the implementation and translatability of these technologies. The foreign body response (FBR) and the encapsulating glial scar have been associated with a decay in chronic performance of implanted electrodes. Moreover, the morphology, intrinsic properties, and function of cells vary across cortical layers, each potentially affecting the sensitivity to ICMS as well as the degree of the FBR across cortical depth. However, layer-by-layer comparisons of the long-term stability of ICMS as well as the extent of the astrocytic glial scar change across cortical layers have not been well explored. Here, we implanted silicon microelectrodes with electrode sites spanning all the layers of S1 in rats. Using a behavioral paradigm, we obtained ICMS detection thresholds from all cortical layers for up to 40 weeks. Our results showed that the sensitivity and long-term performance of ICMS is indeed layer dependent. Overall, detection thresholds decreased during the first 7 weeks post-implantation (WPI). This was followed by a period in which thresholds remained stable or increased depending on the interfacing layer: thresholds in L1 and L6 exhibited the most consistent increases over time, while those in L4 and L5 remained the most stable. Furthermore, histological investigation of the tissue surrounding the electrode showed a biological response of microglia and macrophages which peaked at L1, while the area of the astrocytic glial scar peaked at L2/3. Interestingly, the biological response of these FBR markers is less exacerbated at L4 and L5, suggesting a potential link between the FBR and the long-term stability of ICMS. These findings suggest that interfacing depth can play an important role in the design of chronically stable implantable microelectrodes.

10.
eNeuro ; 9(1)2022.
Artigo em Inglês | MEDLINE | ID: mdl-35058311

RESUMO

Over half of all spinal cord injuries (SCIs) are cervical, which can lead to paralysis and respiratory compromise, causing significant morbidity and mortality. Effective treatments to restore breathing after severe upper cervical injury are lacking; thus, it is imperative to develop therapies to address this. Epidural stimulation has successfully restored motor function after SCI for stepping, standing, reaching, grasping, and postural control. We hypothesized that closed-loop stimulation triggered via healthy hemidiaphragm EMG activity has the potential to elicit functional neuroplasticity in spinal respiratory pathways after cervical SCI (cSCI). To test this, we delivered closed-loop, electrical, epidural stimulation (CLES) at the level of the phrenic motor nucleus (C4) for 3 d after C2 hemisection (C2HS) in freely behaving rats. A 2 × 2 Latin Square experimental design incorporated two treatments, C2HS injury and CLES therapy resulting in four groups of adult, female Sprague Dawley rats: C2HS + CLES (n = 8), C2HS (n = 6), intact + CLES (n = 6), intact (n = 6). In stimulated groups, CLES was delivered for 12-20 h/d for 3 d. After C2HS, 3 d of CLES robustly facilitated the slope of stimulus-response curves of ipsilesional spinal motor evoked potentials (sMEPs) versus nonstimulated controls. To our knowledge, this is the first demonstration of CLES eliciting respiratory neuroplasticity after C2HS in freely behaving animals. These findings suggest CLES as a promising future therapy to address respiratory deficiency associated with cSCI.


Assuntos
Traumatismos da Medula Espinal , Animais , Diafragma , Feminino , Plasticidade Neuronal , Ratos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica/fisiologia , Respiração , Medula Espinal/metabolismo , Traumatismos da Medula Espinal/complicações
12.
Biomaterials ; 279: 121212, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34717196

RESUMO

Peripheral nerve injuries can be debilitating to motor and sensory function, with severe cases often resulting in complete limb amputation. Over the past two decades, prosthetic limb technology has rapidly advanced to provide users with crude motor control of up to 20° of freedom; however, the nerve-interfacing technology required to provide high movement selectivity has not progressed at the same rate. The work presented here focuses on the development of a magnetically aligned regenerative tissue-engineered electronic nerve interface (MARTEENI) that combines polyimide "threads" encapsulated within a magnetically aligned hydrogel scaffold. The technology exploits tissue-engineered strategies to address concerns over traditional peripheral nerve interfaces including poor axonal sampling through the nerve and rigid substrates. A magnetically templated hydrogel is used to physically support the polyimide threads while also promoting regeneration in close proximity to the electrode sites on the polyimide. This work demonstrates the utility of magnetic templating for use in tuning the mechanical properties of hydrogel scaffolds to match the stiffness of native nerve tissue while providing an aligned substrate for Schwann cell migration in vitro. MARTEENI devices were fabricated and implanted within a 5-mm-long rat sciatic-nerve transection model to assess regeneration at 6 and 12 weeks. MARTEENI devices do not disrupt tissue remodeling and show axon densities equivalent to fresh tissue controls around the polyimide substrates. Devices are observed to have attenuated foreign-body responses around the polyimide threads. It is expected that future studies with functional MARTEENI devices will be able to record and stimulate single axons with high selectivity and low stimulation regimes.


Assuntos
Regeneração Nervosa , Tecido Nervoso , Animais , Axônios , Eletrônica , Ratos , Células de Schwann , Nervo Isquiático , Engenharia Tecidual
13.
Front Neurosci ; 15: 712578, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34566563

RESUMO

Intracortical microelectrodes are neuroprosthetic devices used in brain-machine interfaces to both record and stimulate neural activity in the brain. These technologies have been improved by advances in microfabrication, which have led to the creation of subcellular and high-density microelectrodes. The greater number of independent stimulation channels in these devices allows for improved neuromodulation selectivity, compared to single-site microelectrodes. Elements of electrode design such as electrode-site placement can influence the long-term performance of neuroprostheses. Previous studies have shown that electrode-sites placed on the edge of a planar microelectrode have greater chronic recording functionality than sites placed in the center. However, the effect of electrode-site placement on long-term intracortical microstimulation (ICMS) is still unknown. Here, we show that, in rats chronically implanted with custom-made planar silicon microelectrodes, electrode-sites on the tip of the device outperformed those on both the edge and center in terms of the effect per charge delivered, though there is still a slight advantage to using edge sites over center sites for ICMS. Longitudinal analysis of ICMS detection thresholds over a 16-week period revealed that while all sites followed a similar trend over time, the tip and edge sites consistently elicited the behavioral response with less charge compared to center sites. Furthermore, we quantified channel activity over time and found that edge sites remained more active than center sites over time, though the rate of decay of active sites for center and edge sites was comparable. Our results demonstrate that electrode-site placement plays an important role in the long-term stability of intracortical microstimulation and could be a potential factor to consider in the design of future intracortical electrodes.

14.
Adv Nanobiomed Res ; 1(8)2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34485991

RESUMO

Imbalance of oxidants is a universal contributor to the failure of implanted devices and tissues. A sustained oxidative environment leads to cytotoxicity, prolonged inflammation, and ultimately host rejection of implanted devices/grafts. The incorporation of antioxidant materials can inhibit this redox/inflammatory cycle and enhance implant efficacy. Cerium oxide nanoparticles (CONP) is a highly promising agent that exhibits potent, ubiquitous, and self-renewable antioxidant properties. Integrating CONP as surface coatings provides ease in translating antioxidant properties to various implants/grafts. Herein, we describe the formation of CONP coatings, generated via the sequential deposition of CONP and alginate, and the impact of coating properties, pH, and polymer molecular weight, on their resulting redox profile. Investigation of CONP deposition, layer formation, and coating uniformity/thickness on their resulting oxidant scavenging activity identified key parameters for customizing global antioxidant properties. Results found lower molecular weight alginates and physiological pH shift CONP activity to a higher H2O2 to O2 --scavenging capability. The antioxidant properties measured for these various coatings translated to distinct antioxidant protection to the underlying encapsulated cells. Information gained from this work can be leveraged to tailor coatings towards specific oxidant-scavenging applications and prolong the function of medical devices and cellular implants.

15.
J Neurophysiol ; 126(2): 607-626, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34232771

RESUMO

Traumatic cervical spinal cord injury (cSCI) can lead to damage of bulbospinal pathways to the respiratory motor nuclei and consequent life-threatening respiratory insufficiency due to respiratory muscle paralysis/paresis. Reports of electrical epidural stimulation (EES) of the lumbosacral spinal cord to enable locomotor function after SCI are encouraging, with some evidence of facilitating neural plasticity. Here, we detail the development and success of EES in recovering locomotor function, with consideration of stimulation parameters and safety measures to develop effective EES protocols. EES is just beginning to be applied in other motor, sensory, and autonomic systems; however, there has only been moderate success in preclinical studies aimed at improving breathing function after cSCI. Thus, we explore the rationale for applying EES to the cervical spinal cord, targeting the phrenic motor nucleus for the restoration of breathing. We also suggest cellular/molecular mechanisms by which EES may induce respiratory plasticity, including a brief examination of sex-related differences in these mechanisms. Finally, we suggest that more attention be paid to the effects of specific electrical parameters that have been used in the development of EES protocols and how that can impact the safety and efficacy for those receiving this therapy. Ultimately, we aim to inform readers about the potential benefits of EES in the phrenic motor system and encourage future studies in this area.


Assuntos
Respiração , Traumatismos da Medula Espinal/terapia , Estimulação da Medula Espinal/métodos , Animais , Medula Cervical/fisiopatologia , Humanos , Plasticidade Neuronal , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/reabilitação
16.
Neurobiol Learn Mem ; 184: 107498, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34332068

RESUMO

Cognitive flexibility is a prefrontal cortex-dependent neurocognitive process that enables behavioral adaptation in response to changes in environmental contingencies. Electrical vagus nerve stimulation (VNS) enhances several forms of learning and neuroplasticity, but its effects on cognitive flexibility have not been evaluated. In the current study, a within-subjects design was used to assess the effects of VNS on performance in a novel visual discrimination reversal learning task conducted in touchscreen operant chambers. The task design enabled simultaneous assessment of acute VNS both on reversal learning and on recall of a well-learned discrimination problem. Acute VNS delivered in conjunction with stimuli presentation during reversal learning reliably enhanced learning of new reward contingencies. Enhancement was not observed, however, if VNS was delivered during the session but was not coincident with presentation of to-be-learned stimuli. In addition, whereas VNS delivered at 30 HZ enhanced performance, the same enhancement was not observed using 10 or 50 Hz. Together, these data show that acute VNS facilitates reversal learning and indicate that the timing and frequency of the VNS are critical for these enhancing effects. In separate rats, administration of the norepinephrine reuptake inhibitor atomoxetine also enhanced reversal learning in the same task, consistent with a noradrenergic mechanism through which VNS enhances cognitive flexibility.


Assuntos
Reversão de Aprendizagem , Estimulação do Nervo Vago , Inibidores da Captação Adrenérgica , Animais , Cloridrato de Atomoxetina/farmacologia , Baclofeno/farmacologia , Condicionamento Operante/efeitos dos fármacos , Condicionamento Operante/fisiologia , Aprendizagem por Discriminação/efeitos dos fármacos , Aprendizagem por Discriminação/fisiologia , Agonistas dos Receptores de GABA-B/farmacologia , Masculino , Ratos , Ratos Endogâmicos BN , Reversão de Aprendizagem/efeitos dos fármacos , Reversão de Aprendizagem/fisiologia
17.
Front Hum Neurosci ; 15: 644593, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33953663

RESUMO

We estimate that 208,000 deep brain stimulation (DBS) devices have been implanted to address neurological and neuropsychiatric disorders worldwide. DBS Think Tank presenters pooled data and determined that DBS expanded in its scope and has been applied to multiple brain disorders in an effort to modulate neural circuitry. The DBS Think Tank was founded in 2012 providing a space where clinicians, engineers, researchers from industry and academia discuss current and emerging DBS technologies and logistical and ethical issues facing the field. The emphasis is on cutting edge research and collaboration aimed to advance the DBS field. The Eighth Annual DBS Think Tank was held virtually on September 1 and 2, 2020 (Zoom Video Communications) due to restrictions related to the COVID-19 pandemic. The meeting focused on advances in: (1) optogenetics as a tool for comprehending neurobiology of diseases and on optogenetically-inspired DBS, (2) cutting edge of emerging DBS technologies, (3) ethical issues affecting DBS research and access to care, (4) neuromodulatory approaches for depression, (5) advancing novel hardware, software and imaging methodologies, (6) use of neurophysiological signals in adaptive neurostimulation, and (7) use of more advanced technologies to improve DBS clinical outcomes. There were 178 attendees who participated in a DBS Think Tank survey, which revealed the expansion of DBS into several indications such as obesity, post-traumatic stress disorder, addiction and Alzheimer's disease. This proceedings summarizes the advances discussed at the Eighth Annual DBS Think Tank.

18.
J Neural Eng ; 18(5)2021 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-33706301

RESUMO

Objective. Intracortical microstimulation of the primary somatosensory cortex (S1) has shown great progress in restoring touch sensations to patients with paralysis. Stimulation parameters such as amplitude, phase duration, and frequency can influence the quality of the evoked percept as well as the amount of charge necessary to elicit a response. Previous studies in V1 and auditory cortices have shown that the behavioral responses to stimulation amplitude and phase duration change across cortical depth. However, this depth-dependent response has yet to be investigated in S1. Similarly, to our knowledge, the response to microstimulation frequency across cortical depth remains unexplored.Approach. To assess these questions, we implanted rats in S1 with a microelectrode with electrode-sites spanning all layers of the cortex. A conditioned avoidance behavioral paradigm was used to measure detection thresholds and responses to phase duration and frequency across cortical depth.Main results. Analogous to other cortical areas, the sensitivity to charge and strength-duration chronaxies in S1 varied across cortical layers. Likewise, the sensitivity to microstimulation frequency was layer dependent.Significance. These findings suggest that cortical depth can play an important role in the fine-tuning of stimulation parameters and in the design of intracortical neuroprostheses for clinical applications.


Assuntos
Córtex Somatossensorial , Percepção do Tato , Animais , Estimulação Elétrica , Humanos , Microeletrodos , Ratos , Tato
19.
J Med Eng Technol ; 45(3): 187-196, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33729074

RESUMO

Activation of peripheral nervous system (PNS) fibres to produce variable tactile and proprioceptive sensations in advanced bidirectional prosthetic limbs relies on neural stimulators with high spatial selectivity, dynamic range and resolution. A multi-channel application-specific integrated circuit (ASIC) is developed for PNS fibre activation using a wide dynamic range (10 nA-5 mA), high-resolution (30 nA step, 100 ns pulse accuracy) current stimulator, dissipating 0.73-2.75 mW at 3 V. The ASIC also enables encoding of external pressure signals via an integrate-and-fire methodology. Electrophysiological data of compound nerve action potentials were recorded for a range of stimulus amplitudes and pulse widths. This data was used to benchmark the performance of the ASIC with a known neural stimulator.


Assuntos
Nervos Periféricos
20.
Commun Biol ; 4(1): 107, 2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33495588

RESUMO

Respiratory insufficiency is a leading cause of death due to drug overdose or neuromuscular disease. We hypothesized that a stimulation paradigm using temporal interference (TI) could restore breathing in such conditions. Following opioid overdose in rats, two high frequency (5000 Hz and 5001 Hz), low amplitude waveforms delivered via intramuscular wires in the neck immediately activated the diaphragm and restored ventilation in phase with waveform offset (1 Hz or 60 breaths/min). Following cervical spinal cord injury (SCI), TI stimulation via dorsally placed epidural electrodes uni- or bilaterally activated the diaphragm depending on current and electrode position. In silico modeling indicated that an interferential signal in the ventral spinal cord predicted the evoked response (left versus right diaphragm) and current-ratio-based steering. We conclude that TI stimulation can activate spinal motor neurons after SCI and prevent fatal apnea during drug overdose by restoring ventilation with minimally invasive electrodes.


Assuntos
Apneia/prevenção & controle , Diafragma/fisiologia , Terapia por Estimulação Elétrica/métodos , Overdose de Opiáceos/complicações , Traumatismos da Medula Espinal/complicações , Animais , Apneia/etiologia , Feminino , Masculino , Modelos Biológicos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...