Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
2.
Sci Adv ; 8(27): eabn7006, 2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35857459

RESUMO

The treatment of difficult-to-heal wounds remains a substantial clinical challenge due to deteriorative tissue microenvironment including the loss of extracellular matrix (ECM), excessive inflammation, impaired angiogenesis, and bacterial infection. Inspired by the chemical components, fibrous structure, and biological function of natural ECM, antibacterial and tissue environment-responsive glycopeptide hybrid hydrogel was developed for chronic wound healing. The hydrogel can facilitate the cell proliferation and macrophage polarization to M2 phenotype, and show potent antibacterial efficacy against both Gram-negative and Gram-positive bacteria. Significantly, the glycopeptide hydrogel accelerated the reconstruction of methicillin-resistant Staphylococcus aureus (MRSA)-infected full-thickness diabetic and scalding skin by orchestrating a pro-regenerative response indicated by abundant M2-type macrophages, attenuated inflammation, and promoted angiogenesis. Collectively, ECM-mimetic and immunomodulatory glycopeptide hydrogel is a promising multifunctional dressing to reshape the damaged tissue environment without additional drugs, exogenous cytokines, or cells, providing an effective strategy for the repair and regeneration of chronic cutaneous wounds.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Antibacterianos/química , Antibacterianos/farmacologia , Matriz Extracelular , Glicopeptídeos/farmacologia , Humanos , Hidrogéis/química , Hidrogéis/farmacologia , Inflamação , Cicatrização
3.
Regen Biomater ; 9: rbac003, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35668921

RESUMO

Titanium alloy has been widely used in orthopedic surgeries as bone defect filling. However, the regeneration of high-quality new bones is limited due to the pro-inflammatory microenvironment around implants, resulting in a high occurrence rate of implant loosening or failure in osteological therapy. In this study, extracellular matrix-mimetic polysaccharide hydrogel co-delivering BMP-2 and interleukin (IL)-4 was composited with 3D printed titanium alloy to promote the osseointegration and regulate macrophage response to create a pro-healing microenvironment in bone defect. Notably, it is discovered from the bioinformatics data that IL-4 and BMP-2 could affect each other through multiple signal pathways to achieve a synergistic effect toward osteogenesis. The composite scaffold significantly promoted the osteoblast differentiation and proliferation of human bone marrow mesenchyme stem cells (hBMSCs). The repair of large-scale femur defect in rat indicated that the dual-cytokine-delivered composite scaffold could manipulate a lower inflammatory level in situ by polarizing macrophages to M2 phenotype, resulting in superior efficacy of mature new bone regeneration over the treatment of native titanium alloy or that with an individual cytokine. Collectively, this work highlights the importance of M2-type macrophages-enriched immune-environment in bone healing. The biomimetic hydrogel-metal implant composite is a versatile and advanced scaffold for accelerating in vivo bone regeneration, holding great promise in treating orthopedic diseases.

5.
Ann Transl Med ; 10(2): 97, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35282054

RESUMO

Background: Balloon-expandable valves (BEV) and self-expanding valves (SEV) for transcatheter aortic valve replacement (TAVR) have shown promising results in Western populations. Herein, we comparatively evaluated their hemodynamics and early clinical outcomes in a Chinese population. Methods: One hundred seventy-eight patients with symptomatic aortic stenosis who had undergone transfemoral TAVR using SEV (n=153; Venus-A, 97; VitaFlow, 56) or BEV (n=25; Sapien3) from September 2020 to April 2021 were retrospectively enrolled, and 25 pairs were propensity-score matched for 10 baseline variables. The primary study outcomes were aortic valve hemodynamics and postoperative complications at discharge and 3-month follow-up. Results: TAVR was successful in all patients. Compared with SEV group, the BEV group had similarly distributed baseline characteristics, procedural time, hospital stay, new pacemaker implantation, and paravalvular regurgitation grade. We also observed that the BEV group had lower rates of balloon pre-dilation (60% vs. 92%, P=0.018), post-dilation (0 vs. 20%, P=0.050) and second valve implantation (0 vs. 24%, P=0.022); higher mean transaortic gradient (14.3±6.1 vs. 10.8±4.9, P=0.030) and proportion of patients with elevated gradients (20% vs. 0, P=0.050) at discharge; and similar rehospitalization, mean transaortic gradient, new pacemaker implantation, and paravalvular regurgitation grade than the SEV group at the 3-month follow-up. There were no deaths in either group. However, the proportion of patients with elevated gradients in SEV group was higher at 3 months than before discharge (24% vs. 0, P=0.022). Conclusions: BEV and SEV for transfemoral TAVR appear comparably safe and effective, with high device success and favorable 3-month clinical outcomes. However, the transaortic gradient and new pacemaker implantation in the SEV group increased during follow-up, warranting larger studies with longer-term follow-up.

6.
Adv Healthc Mater ; 10(22): e2101247, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34473428

RESUMO

Clinical wound management remains a major challenge due to massive bleeding, bacterial infection, and difficult wound healing after tissue trauma. To simultaneously address these issues, composite polymer sponges for accelerating drug-resistant bacterial infected wound healing are fabricated by facilely mixing sodium polyacrylate (PAAS), double quaternary ammonium salts-conjugated chitosan (QAS-CS), and collagen (COL) in aqueous solution, followed by lyophilization. Composite sponges (PAAS/QAS-CS/COL, PQC) show highly porous microstructures (porosity ≈90%) with moderate compress modulus (≈0.3 MPa), tensile strength (0.004 MPa), and high swelling ratio (≈3500%). Importantly, PQC sponge demonstrates superior hemostasis ability over commercially available CS sponge by inducing rapid hemagglutination, and exhibits significantly better antibacterial activity against both methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli by destroying cell membrane and causing the leakage of bioactive components such as potassium ion and ß-galactosidase from treated bacterial. Furthermore, PQC sponge can efficiently promote cell proliferation. Significantly, the sponge greatly expedites the regeneration of MRSA-infected full-thickness skin wound in rabbit by successfully eradicating bacterial infection, and reducing inflammation. PQC sponge also improves both early angiogenesis and blood vessel maturation at the wound site. Overall, this multifunctional sponge is a promising wound dressing for clinical use and holds great potential for rapid clinical translation.


Assuntos
Quitosana , Hemostáticos , Staphylococcus aureus Resistente à Meticilina , Animais , Antibacterianos/farmacologia , Hemostasia , Hemostáticos/farmacologia , Inflamação/tratamento farmacológico , Polímeros , Coelhos , Cicatrização
7.
ACS Nano ; 14(10): 12905-12917, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32946218

RESUMO

Antibacterial hydrogels are attracting extensive attention in soft tissue repair and regeneration, including bacteria-infected-wound healing. The abuse of antibiotics leads to drug resistance. Recent developments have demonstrated that the delivery of inorganic bactericidal agents in hydrogels can drive the wound healing process; however, this approach is complicated by external light stimuli, cytotoxicity, nondegradability, and sophisticated fabrication. Herein, an inherent antibacterial, bioresorbable hydrogel was developed by the spontaneous self-aggregation of amphiphilic, oxadiazole-group-decorated quaternary ammonium salts (QAS)-conjugated poly(ε-caprolactone)-poly(ethylene glycol)-poly(ε-caprolactone) (PCEC-QAS) micellar nanoantimicrobials for methicillin-resistant Staphylococcus aureus (MRSA)-infected cutaneous wound healing. The PCEC-QAS hydrogel showed a stable gel state within the temperature range of 5-50 °C and antibacterial efficacy against both Gram-negative and -positive bacteria in vitro and in vivo. Additionally, the PCEC-QAS hydrogel facilitated the cell spreading, proliferation, and migration without cytotoxicity. An in vivo degradation and skin defect healing study suggested the PCEC-QAS hydrogel was totally absorbed without local or systemic toxicity and could promote wound repair in the absence of drugs, cytokines, or cells. Significantly, this hydrogel accelerated the regeneration of a MRSA-infected full-thickness impaired skin wound by successfully reconstructing an intact and thick epidermis similar to normal mouse skin. Collectively, a self-assembling PCEC-QAS antibacterial hydrogel is a promising dressing material to promote skin regeneration and prevent bacterial infection without additional drugs, cells, light irradiation, or delivery systems, providing a simple but effective strategy for treating dermal wounds.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Animais , Antibacterianos/farmacologia , Citocinas , Hidrogéis , Camundongos , Cicatrização
8.
J Cardiol ; 76(3): 236-243, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32451153

RESUMO

BACKGROUND: Percutaneous balloon pulmonary valvuloplasty (PBPV) is the procedure of choice for uncomplicated severe or symptomatic pulmonary stenosis. Echocardiography (echo)-guided PBPV can completely avoid the use of radiation and contrast agents compared to fluoroscopy-guided PBPV. Although we have confirmed that echo-guided PBPV is feasible in humans, the poor visibility of the traditional catheter under echo greatly limits the promotion of this new technology. METHODS: We produced a novel double-balloon catheter to make the catheter easy to be detected by echo through adding a guiding balloon at the distal end of the catheter. Echo-guided PBPV was performed on thirty healthy swine using either a novel catheter or a traditional catheter to evaluate the feasibility and safety of the novel double-balloon catheter. The feasibility was evaluated by the success rate of balloon inflation at the pulmonary valve annulus and the operating time. The safety was evaluated by the frequency of balloon slippage and the incidence of complications. RESULTS: There were no significant between-group differences in terms of weight and the ratio of balloon diameter to pulmonary annulus diameter. The success rate was 93.3% and 60% in the novel and traditional groups, respectively. The novel group had significantly (p<0.05) lower mean procedure time (6.33±6.86min vs 24.8±9.79min) and lower frequency of balloon slippage (0.07±0.26 vs 0.53±0.52), arrhythmia (0.07±0.26 vs 0.47±0.52), and tricuspid regurgitation (6.7% vs 40%) than the traditional group. No myocardial hematoma or pericardial tamponade occurred in the novel catheter group. CONCLUSION: Although further studies and improvements are required, the study results indicate that the novel double-balloon catheter for echo-guided PBPV is feasible and safe.


Assuntos
Valvuloplastia com Balão/instrumentação , Catéteres , Ecocardiografia/métodos , Valva Pulmonar/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Valvuloplastia com Balão/métodos , Desenho de Equipamento , Estudos de Viabilidade , Modelos Animais , Estenose da Valva Pulmonar/cirurgia , Suínos , Resultado do Tratamento
9.
Ann Thorac Surg ; 110(3): 980-987, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32087135

RESUMO

BACKGROUND: A percutaneous approach for pulmonary valve replacement (PVR) is a feasible alternative to surgical PVR in selected patients with severe pulmonary regurgitation after repair of tetralogy of Fallot. However, large right ventricular outflow tract (diameter ≥ 25 mm) remains challenging. METHODS: This retrospective multicenter study enrolled consecutive patients with large right ventricular outflow tract who underwent percutaneous PVR (Venus P-valve, Venus MedTech Inc, Hangzhou, China) (n = 35) or surgical PVR (homograft valve; n = 30) between May 2014 and April 2017. Patients were followed up at 1, 3, 6, and 12 months, and yearly thereafter. Main study outcomes were pulmonary valve function and right ventricular function at discharge and midterm follow-up. RESULTS: PVR was successful in all patients. Percutaneous compared with surgical PVR group had: similarly distributed baseline characteristics; shorter hospitalization, intensive care unit stay, and endotracheal intubation duration; lower cost; lower pulmonary valve gradient before discharge; lower pulmonary valve regurgitant grade (mean difference, -0.63; 95% CI -1.11 to -0.20, P = .022), pulmonary valve gradient (mean difference, -5.7 mm Hg; 95% CI -9.4 to -2.2 mm Hg, P = .005), and right ventricular end-diastolic volume index (mean difference, -9.5 mL/m2; 95% CI -16.9 to -3.1 mL/m2, P = .022); and greater right ventricular ejection fraction (mean difference, 5.4%; 95% CI 2.4%-8.3%, P = .002) at median 36 months follow-up, without deaths in either group. CONCLUSIONS: Percutaneous PVR using Venus P-valve appeared to be a safe, efficacious and minimally invasive alternative to surgical PVR in selected patients with large right ventricular outflow tract yielding better right ventricular and pulmonary valve function at midterm follow-up.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Volume Sistólico/fisiologia , Função Ventricular Direita/fisiologia , Adulto , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos
10.
Soft Matter ; 16(8): 2141-2148, 2020 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-32016231

RESUMO

Poly(l-lactic acid) (PLLA) scaffolds have been used in regenerative medicine, however, they commonly suffer from low flexibility, restricting their application in the repair and reconstruction of soft tissues. In this study, poly(l-lactide-co-ε-caprolactone) (PLCL) copolymers were examined to modulate the elasticity of PLLA with the random presence of CL units in PLLA. Thermodynamic analysis revealed that the introduction of PCL could significantly decrease the melting point and glass transition temperature of PLLA, benefiting the extrusion and printing of PLCL. Diverse scaffolds with designed architectures including porous cubes with or without large holes, cambered plates with holes and round tubes could be easily constructed by 3D printing. In the process of elastic deformation, the maximum elastic stress of the copolymer scaffold was obviously increased from 19.6 to 31.5 MPa when the relative content of PCL was increased to 70%, while the elongation at break was evidently increased from 388% to about 1974%. The Young's modulus of PLCL was also significantly decreased (P < 0.05) in comparison with that of PLLA. PLCL scaffolds have good platelet and endotheliocyte adhesion ability and no obvious hemolysis was observed. In vivo subcutaneous implantation of PLCL scaffolds demonstrated superior biocompatibility. Collectively, this work highlights that copolymerization of PCL segments into PLLA is an effective approach to tune the 3D printability and the stiffness and elasticity of PLLA scaffolds. PLCL scaffolds hold great promise for the regeneration of soft tissues including but not limited to cartilage, myocardium, muscle, tendon and nervous tissues.


Assuntos
Poliésteres/química , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/química , Fenômenos Biomecânicos , Plaquetas/citologia , Adesão Celular , Proliferação de Células , Elasticidade , Células Endoteliais da Veia Umbilical Humana/citologia , Humanos , Impressão Tridimensional , Coelhos , Engenharia Tecidual/instrumentação
11.
Adv Healthc Mater ; 8(19): e1900840, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31512403

RESUMO

Mesoporous silica nanoparticles (MSNs) show great promise to be exploited as versatile multifunctional nanocarriers for effective cancer diagnosis and treatment. In this work, perfluorohexane (PFH)-encapsulated MSNs with indocyanine green (ICG)-polydopamine (PDA) layer and poly(ethylene glycol)-folic acid coating (designated as MSNs-PFH@PDA-ICG-PEG-FA) are successfully fabricated to achieve tumor ultrasonic (US)/near-infrared fluorescence (NIRF) imaging as well as photothermal therapy (PTT)/photodynamic therapy (PDT). MSNs-PFH@PDA-ICG-PEG-FA exhibits good monodispersity with high ICG loading, significantly enhances ICG photostability, and greatly improves cellular uptake. Upon single 808 nm NIR irradiation, the nanocarrier not only efficiently generates hyperthermia to realize PTT, but also produces reactive oxygen species (ROS) for effective PDT. Meanwhile, NIR irradiation can trigger PFH to undergo vaporization and provide a super-resolution US image. Thus, the PTT/PDT combination therapy can be dually guided by PFH-induced US imaging and ICG-induced NIRF imaging. In vivo antitumor studies demonstrate that PTT/PDT from MSNs-PFH@PDA-ICG-PEG-FA significantly inhibits tumor growth and achieves a cure rate of 60% (three out of five mice are completely cured). Hence, the multifunctional MSNs appear to be a promising theragnostic nanoplatform for multimodal cancer imaging and therapy.


Assuntos
Nanopartículas/química , Neoplasias/terapia , Fototerapia/métodos , Dióxido de Silício/química , Nanomedicina Teranóstica/instrumentação , Animais , Feminino , Fluorocarbonos/química , Ácido Fólico/química , Humanos , Hipertermia Induzida , Verde de Indocianina/química , Indóis/química , Células MCF-7 , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Microscopia Confocal , Fotoquimioterapia , Polietilenoglicóis/química , Polímeros/química , Espécies Reativas de Oxigênio/química , Temperatura , Nanomedicina Teranóstica/métodos
12.
J Thorac Dis ; 11(6): 2297-2304, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31372266

RESUMO

BACKGROUND: Conventional percutaneous closure of patent foramen ovale (PFO) is usually performed under the guidance of fluoroscopy. Whether closure of PFO under transthoracic echocardiography (TTE) guidance only is safe and effective is unknown. The present study therefore aimed to assess the safety and efficacy of percutaneous closure of PFO under TTE guidance only. METHODS: This study retrospectively enrolled a total of 52 consecutive patients (55.8% male, mean age 34.0±13.0 years, range, 10-59 years) with PFO treated at our institution from June 2015 to September 2017 by percutaneous closure under echocardiographic guidance only. The patients mean body weight was 58.7±10.8 kg. Patients underwent follow-up by TTE immediately post procedure by electrocardiogram and TTE at 1, 3, 6 and 12 months after discharge and annually thereafter, and by clinical evaluation at all time points. RESULTS: Of the 52 patients, 47 (90.4%) were successfully treated by percutaneous closure under TTE guidance. The mean procedure duration (from puncture to sheath removal) was 21.0±6.2 (range, 11-33) minutes. A trivial residual shunt which disappeared 24 hours later was observed in only 1 (1.9%) patient immediately post procedure. Median hospital stay was 3.0 days without severe complications such as peripheral vascular injury or cardiac perforation at discharge. At median 15.5 (11.3, 18.0) months follow-up, there were no complications such as death, stroke, transient ischemic attack (TIA) and residual shunt. CONCLUSIONS: In this single center study of mostly lean patients, percutaneous closure of PFO under TTE guidance as the only imaging tool appeared effective at midterm follow-up, while avoiding radiation exposure, endotracheal intubation and contrast agent use.

13.
J Biomed Nanotechnol ; 14(12): 2018-2030, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30305210

RESUMO

We have developed redox-sensitive folic acid-conjugated PCL-PEG-PCL (PCEP) nanoparticles for co-delivering chemotherapeutic agent doxorubicin (DOX) and imaging and hyperthermia agent indocyanine green (ICG) with simultaneous imaging and combined therapy for breast cancer. DOX and ICG were entrapped into PCEP nanoparticles through the thin-film hydration and ultrasonic dispersion. Then nanoparticles were surface decorated with folic acid ligands against FR overexpressing breast cancers. Drug-loading nanoparticles exhibited an enhanced reduction-sensitivity in the presence of 10 mM glutathione. Nanoparticle-mediated treatment had synergistic cytotoxicity against mammary cancer cells. The conjugation of folic acid improved the uptake of nanoparticles in EMT-6 breast cancer overexpressing cell lines, and the uptake efficacy of DOX was remarkably increased by the laser irradiation. Furthermore, ex vivo fluorescence imaging confirmed that folate conjugation also improved drug accumulation in tumor. Our unique FA-DINPs system has potential for combination of chemotherapy and photothermal therapy for breast cancer.


Assuntos
Neoplasias da Mama , Nanopartículas , Doxorrubicina , Ácido Fólico , Humanos , Oxirredução
14.
J Healthc Eng ; 2018: 5784567, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30057731

RESUMO

Objective: To assess the effectiveness of a novel ultrasound wire for echo-guiding percutaneous atrial septal defect (ASD) closure in a sheep model. Methods: After right lateral thoracotomy, ASDs were created in 20 sheep by transseptal needle puncture followed by balloon dilatation. Animals were evenly randomized into 2 groups to undergo ASD closure using echography as the only imaging tool with either COOK wire (control group) or new ultrasound wire (study group). The total procedural time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into the right atrium, frequency of arrhythmias, and 1-week rate of complications were compared between the two groups. Results: All animals survived defect creation procedures uneventfully. ASD devices were successfully implanted in all sheep. Compared with the control group, the study group had significantly (P < 0.05) lower mean procedure time (15.36 ± 4.86 versus 25.82 ± 7.85 min), lower mean passing time (2.69 ± 0.82 versus 5.58 ± 3.34 min), lower frequency of the guide wire dropping into the right atrium (0% versus 40%), and lower frequency of atrial (4.41 ± 2.61 versus 9.60 ± 3.68) or ventricular premature contractions (0.75 ± 0.36 versus 1.34 ± 0.68), respectively, without serious complications up to one week. Conclusion: The novel ultrasound specialized guide wire was effective in echo-guiding percutaneous ASD closure.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial , Dispositivo para Oclusão Septal , Animais , Feminino , Seguimentos , Distribuição Aleatória , Ovinos , Toracotomia/métodos , Resultado do Tratamento , Ultrassonografia
15.
Echocardiography ; 35(10): 1507-1511, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29920758

RESUMO

OBJECTIVE: Percutaneous balloon mitral valvuloplasty (PBMV) is the treatment of choice in patients with isolated mitral stenosis. This study aimed to assess the feasibility of PBMV under echocardiography guidance only of isolated mitral stenosis (MS). METHODS: From October 2016 to Dec 2017, 20 consecutive patients with severe MS underwent PBMV with echocardiography as the only imaging modality at a single center. Outpatient follow-up including chest radiography, electrocardiography, and transthoracic echocardiography was conducted at 1, 3,6, and 12 months after the procedure. RESULTS: All 20 patients successfully underwent PBMV under echocardiography guidance without radiation and contrast agent. Among them, 2 patients were pregnant, 5 had chronic renal failure, and 1 had history of allergy to contrast. Mitral transvalvular pressure gradient measured at catheterization dropped from 13.35 ± 2.85 mm Hg to 5.10 ± 1.17 mm Hg (P < .01). Mitral valve area increased from 0.82 ± 0.10 cm2 pre-PBMV to 1.88 ± 0.24 cm2 post-PBMV (P < .01). Mean balloon diameter was 26.63 ± 0.93 mm. Mild mitral regurgitation developed in 6 patients. Mean follow-up duration was 6.27 ± 3.12 months. At last follow-up, mitral valve area remained high (1.71 ± 0.14 cm2 ) and mean transmitral pressure gradient low (6.07 ± 1.03 mm Hg). No pericardial effusion or peripheral vascular complications occurred. CONCLUSION: In this small experience, PBMV could be successfully performed under only echocardiography guidance and appeared safe and effective while avoiding radiation and contrast agent use.


Assuntos
Valvuloplastia com Balão/métodos , Ecocardiografia/métodos , Estenose da Valva Mitral/terapia , Valva Mitral/diagnóstico por imagem , Radiologia Intervencionista/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/diagnóstico por imagem , Resultado do Tratamento
16.
Ann Thorac Surg ; 105(1): 175-180, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28964424

RESUMO

BACKGROUND: Surgical or percutaneous interventional treatment of severe congenital aortic valve stenosis (CAS) in early infancy remains challenging. This single-center, retrospective study analyzed midterm outcomes of a hybrid balloon valvuloplasty procedure through the ascending aorta by way of median sternotomy, including cases with improved technique. METHODS: Included were 45 consecutive infants (aged <90 days) with CAS and selected for biventricular repair who underwent hybrid balloon valvuloplasty in a hybrid or ordinary operating room from October 2010 to March 2016. Patients were assessed at 1, 3, 6, and 12 months and yearly thereafter. RESULTS: Hybrid balloon valvuloplasty was successful in all patients, with the last 8 treated in an ordinary operating room under only echocardiography guidance with a new sheath. Thirty-two patients were successfully rescued from low heart rate or left ventricular systolic dysfunction, or both, by cardiac massage under direct visualization; none required cardiopulmonary bypass. The degree of new aortic insufficiency was mild in 7 patients and changed from mild to moderate in 1 patient. Aortic valve pressure gradient decreased from 70.6 ± 17.5 mm Hg preoperatively to 15.2 ± 4.2 mm Hg immediately postoperatively (p < 0.001). Fluoroscopy time was 4.8 ± 2.3 minutes. At a median of 32.1 months (range, 1 to 68 months) follow-up, all patients were alive and healthy. Aortic valve pressure gradient remained low (19.1 ± 5.2 mm Hg). Left ventricular ejection fraction increased from 0.515 ± 0.134 (range, 0.21 to 0.70) preoperatively to 0.633 ± 0.035 (range, 0.58 to 0.75; p < 0.001). No aortic insufficiency developed, and no patient required reintervention. CONCLUSIONS: For infants with severe CAS, hybrid balloon valvuloplasty through the ascending aorta by way of a median sternotomy appears efficacious and safe up to midterm follow-up.


Assuntos
Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Aorta , Valvuloplastia com Balão/instrumentação , Seguimentos , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Índice de Gravidade de Doença , Esternotomia , Resultado do Tratamento
17.
Eur J Cardiothorac Surg ; 51(3): 478-482, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28082474

RESUMO

Objectives: To assess safety and effectiveness of symmetric and asymmetric occluders in perventricular device closure without cardiopulmonary bypass of perimembranous ventricular septal defects (pmVSDs). Methods: The present retrospective study enrolled 581 patients who underwent perventricular device closure of pmVSDs under transoesophageal echocardiography guidance from May 2011 to April 2016, and outpatient electrocardiography and transthoracic echocardiography assessments at 1, 3, 6 and 12 months, and yearly thereafter. Results: The overall success rate of device implantation was 92.6% (43 surgical conversions immediately). Between patients receiving symmetric ( n = 353) and asymmetric ( n = 185) occluders, there were no significant differences in age, weight and defect diameter distributions; however, both before discharge and at mean 28.6 ± 21.2 (range, 1-60)-month follow-up, the symmetric group had lower rates of trivial residual shunt (5.7% vs 11.4%, P = 0.018; and 0.8% vs 5.9%, P = 0.001) and bundle branch block (0.8% vs 5.4%, P = 0.002; and 0.6% vs 3.8%, P = 0.009); and at follow-up, the asymmetric group had lower residual shunt (47.6% vs 85.0%, P = 0.020) and similar branch block (30.0% vs 33.3%, P = 1.000) disappearance rates. There were no severe complications, i.e. aortic regurgitation, malignant arrhythmias, haemolysis or device dislocation. Conclusions: Perventricular device closure of pmVSDs appears safe and effective with symmetric and asymmetric occluders. However, the lower residual shunt disappearance and higher branch block incidence rates for asymmetric occluders would favour more proactive conversion to surgical repair immediately when residual shunt is present intraoperatively.


Assuntos
Comunicação Interventricular/cirurgia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Eletrocardiografia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
Congenit Heart Dis ; 11(6): 716-720, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27346469

RESUMO

OBJECTIVE: The objective of this study was to assess the feasibility of percutaneous balloon pulmonary valvuloplasty (PBPV) under echocardiographic guidance only. SETTING: PBPV has become the preferred choice for pulmonary valve stenosis (PS). We report the first-in-human successful PBPV under only echocardiography guidance for isolated PS. METHODS: From March 2013 to December 2014, 34 patients with congenital PS underwent PBPV with echocardiography as the only imaging modality in the ordinary operation room or catheter lab. Outpatient follow-up including chest radiography, electrocardiography, and transthoracic echocardiography (TTE) was conducted at 1, 3, 6, and 12 months. RESULTS: All 34 patients successfully underwent PBPV under echocardiography guidance without radiation and contrast agent. The pulmonic transvalvular pressure gradient dropped from 62.8 ± 10.1 mm Hg to 14.7 ± 4.2 mm Hg measured on catheterization (P < .05). The balloon diameter/pulmonary annulus diameter ratio was 1.34 ± 0.07. Slight regurgitation of the pulmonary valve occurred in five patients and mild pulmonary regurgitation occurred in one patients. The pulmonic transvalvular pressure gradient measured on TTE 12 months after the procedure was 14.1 ± 4.6 mm Hg. No pericardial effusion and peripheral vascular complications occurred. CONCLUSION: This study demonstrated that PBPV can be successfully performed under only echocardiography guidance and appears safe and effective while avoiding radiation and contrast agent use.


Assuntos
Valvuloplastia com Balão/métodos , Ecocardiografia , Estenose da Valva Pulmonar/terapia , Valva Pulmonar/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Adolescente , Valvuloplastia com Balão/efeitos adversos , Criança , Pré-Escolar , China , Ecocardiografia/efeitos adversos , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Masculino , Segurança do Paciente , Valor Preditivo dos Testes , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/congênito , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos
19.
Ann Thorac Surg ; 100(4): 1398-402, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26234660

RESUMO

BACKGROUND: Transesophageal echocardiogram-guided minimally invasive periventricular device closure of perimembranous ventricular septal defects (pmVSDs) without cardiopulmonary bypass is a treatment option for pmVSDs. We introduce our improvements to this technique and mid-term follow-up results. METHODS: From May 2011 to May 2014, 187 patients with pmVSDs aged 6 months to 31 years (8.2 ± 10.2 years) were enrolled in this study. The procedure was performed through a new transthoracic approach of 1 to 2 cm without sternotomy. Device selection and the operative procedure were monitored by transesophageal echocardiogram. The patients underwent follow-up examinations of echocardiography and electrocardiogram at 1 month, 3 months, 6 months, and 1 year after the operation and annually thereafter. RESULTS: The defects were closed successfully in 179 patients (95.7%), and in 8 patients the operation was converted to conventional surgical repair. Six patients (3.4%) had an incomplete right bundle branch block. One patient experienced an intermittent complete atrioventricular block on the fourth day after the operation, and sinus rhythm was restored by corticosteroid therapy after 5 days. A trivial residual shunt was observed in 8 patients (4.5%) during the procedure. The average hospital stay was 3.1 ± 0.9 days. Follow-up in all patients ranged from 1 month to 36 months (median, 12.6 months), and aortic regurgitation, malignant arrhythmia, and device dislocation were not observed in any patients. However, 3 patients (1.7%) still had a trivial residual shunt at their last follow-up. CONCLUSIONS: Periventricular device closure through a modified transthoracic approach without sternotomy is a potentially safe and effective treatment option for pmVSDs. Controlled studies with long-term follow-up are necessary.


Assuntos
Ecocardiografia Transesofagiana/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Cirurgia Assistida por Computador , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia Transesofagiana/instrumentação , Seguimentos , Humanos , Lactente , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Fatores de Tempo , Adulto Jovem
20.
J Interv Cardiol ; 28(4): 390-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26077469

RESUMO

OBJECTIVE: Demonstrate the benefits of percutaneous atrial septal defect (ASD) closure under guidance of transthoracic echocardiography (TTE) without fluoroscopy. METHODS: From February 2013 to April 2014, 127 consecutive patients with an isolated type II ASD were recruited to undergo percutaneous closure under either TTE (n = 60, TTE group) or TEE (n = 67, TEE group) guidance. The TTE group received local anesthesia or sedation with propofol, and the TEE group received general anesthesia with endotracheal intubation. Follow-up examinations were performed for both groups at 1 month, 3 months, 6 months, and 1 year after discharge and annually thereafter. RESULTS: The TTE group had a significantly shorter procedure time and respirator ventilation duration than the TEE group. The dose of propofol required, the cost, and the pharyngeal complication rate were significantly lower in the TTE group than in the TEE group. The median follow-up of 11.6 months was uneventful in all patients. CONCLUSIONS: Percutaneous ASD closure with TTE guidance as the only imaging tool avoids fluoroscopy, endotracheal intubation, and probe insertion and is associated with a satisfactory procedural success rate and lower costs. This procedure is a safe and reliable treatment for ASD.


Assuntos
Cateterismo Cardíaco , Ecocardiografia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Anestesia Geral , Anestesia Local , Criança , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Hipnóticos e Sedativos/administração & dosagem , Intubação Intratraqueal , Masculino , Propofol/administração & dosagem , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...