Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 248: 116311, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38901157

RESUMO

Neuroblastoma (NB), an embryonic tumor of the autonomous nervous system, poses a significant threat to the health and lives of children. Accurate measurement of vanillylmandelic acid (VMA) and homovanillic acid (HVA) in human urine is crucial for screening and diagnosis of NB. Although various laboratories have developed liquid chromatography tandem mass spectrometry (LC-MS/MS) method to detect VMA and HVA, the comparability between the results obtained from different laboratories and methods was poor. The absence of reference method for VMA and HVA hinders the standardization of their measurements. Therefore, a candidate reference measurement procedure (cRMP) based on isotope dilution LC-MS/MS (ID-LC-MS/MS) for the detection of VMA and HVA in human urine was established. Urine samples were spiked with VMA-d3 and HVA-d5 as internal standards and extracted using a protein precipitation method. The cRMP exhibited desirable precision with the total imprecision below 5 %. The accuracy of this cRMP was demonstrated by the high analytical recovery (98.64 % - 102.22 % and 98.41 % - 100.97 % for VMA and HVA, respectively), and comparability between different reference systems. The limit of detection for HVA and VMA were 15.625 ng/mL and 3.906 ng/mL, respectively; the quantification limits were 62.5 ng/mL and 7.813 ng/mL, respectively, which can meet the clinical detection requirements. The linear range was from 78.125 ng/mL to 20 µg/mL. Specificity evaluations showed no corresponding interference from structurally similar analogs. In conclusion, we have established a cRMP based on ID-LC-MS/MS for the measurement of VMA and HVA in urine samples, demonstrating well-defined method performance including accuracy, precision, and specificity. This newly established cRMP is suitable for routine assay standardization and evaluation of clinical samples. Furthermore, this method has the potential to significantly enhance the diagnostic accuracy for neuroblastoma.

3.
J Gastrointest Oncol ; 14(6): 2574-2586, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38196542

RESUMO

Background: Microtubules are attractive targets for anticancer drugs. However, the microtubule-targeting agents (MTAs) currently in clinical use exhibit inevitable drug resistance. Therefore, there is an urgent need to discover novel MTAs for the clinical treatment of cancer. Methods: Bioactive compounds extracted from Lithospermum erythrorhizon were assessed for in vitro anti-proliferative activities against a panel of human cancer cell lines using cell counting kit-8 (CCK-8) assay. Tubulin polymerization inhibition assay, colchicine competitive binding site assay, and immunofluorescence were used to validate the tubulin inhibition effect of acetylshikonin. Flow cytometry, Hoechst staining, and caspase-3 activity evaluation were performed to assess cell cycle arrest and cell apoptosis. 5,5',6,6'-tetrachloro-1,1',3,3'-tetramethylbenzimidazolylcarbocyanine iodide (JC-1) staining and dichloro-dihydro-fluorescein diacetate (DCFH-DA) staining were used to evaluate mitochondrial membrane potential (MMP) and reactive oxygen species (ROS), respectively. Results: Acetylshikonin exhibited potent anti-proliferative activities against a panel of human cancer cell lines (IC50 values: 1.09-7.26 µM) and displayed comparable cytotoxicity against several drug-resistant cell lines. Further mechanism studies revealed that acetylshikonin induced cell cycle arrest of MHCC-97H cells at G2/M phase, and significantly promoted apoptosis marked by a collapse of MMP and abnormal ROS accumulation. Conclusions: In this study, acetylshikonin was identified as MTA against hepatocellular carcinoma and can serve as a promising lead compound for further development of anti-cancer drug, underscoring its potential clinical significance.

4.
J Med Chem ; 65(6): 4687-4708, 2022 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-35282680

RESUMO

Microtubule targeting agents (MTAs) are used as clinically effective chemotherapies for cancer treatment but might be limited by the acquired or intrinsic resistance of cancer cells to apoptosis. The vulnerability of therapy-resistant cancers to ferroptosis provides an alternative way to overcome drug resistance. In this study, on the basis of the MTAs obtained in our previous studies, a series of MTAs were synthesized, and detailed structure-activity relationships were obtained through extensive molecular dynamics studies. Among them, a diphenylethene derivative, compound 33, displayed the most potent activity in vitro and in vivo, with IC50 values of 10-50 nM toward six cancer cell lines and a 78.6% tumor growth inhibition in vivo. Interestingly, although it acted as the MTA, compound 33 triggered cell death mainly through cell ferroptosis rather than apoptosis, which might provide an alternative way to eradicate apoptosis-related drug resistance.


Assuntos
Antineoplásicos , Ferroptose , Neoplasias , Estilbenos , Antineoplásicos/uso terapêutico , Apoptose , Linhagem Celular Tumoral , Humanos , Microtúbulos , Neoplasias/tratamento farmacológico , Estilbenos/farmacologia
5.
Anal Bioanal Chem ; 414(7): 2523-2531, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35211786

RESUMO

To solve long-term lack of traceability of commercial calibrator kits and standardize clinical routine assays, we developed a human serum matrix-based unconjugated estriol (uE3) reference material (RM) with five concentration gradients. The RMs of uE3 were certified by the National Institute of Metrology (NIM) with the codes of GBW (E) 091048, GBW (E) 091049, GBW (E) 091050, GBW (E) 091051, and GBW (E) 091052. The RMs were determined by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) reference method which was developed in our group and recommended by the Joint Committee on Traceability on Laboratory Medicine (JCTLM). GBW09224 is intended for use as a primary reference material to enable the SI-traceable measurement of uE3. This study describes the development process of these certified RMs. The candidate material was prepared by collecting from the remaining serum samples after routine clinical testing. Satisfactory homogeneity and stability were shown in these RMs. They are also commutable between the reference method and the three routine clinical immunoassay systems. To improve the accuracy of value assignment, a collaborative study in nine reference laboratories was conducted which was performed according to ISO/WD 15725-1 and all of the reference laboratories have been confirmed by China National Accreditation Service for Conformity Assessment (CNAS). The raw results were statistically analyzed and processed, coupled with uncertainty evaluation, to obtain the certified value: GBW (E) 091048 is 22.1 ± 1.3 nmol/L, GBW (E) 091049 is 33.6 ± 1.6 nmol/L, GBW (E) 091050 is 10.4 ± 0.8 nmol/L, GBW (E) 091051 is 15.5 ± 1.0 nmol/L, GBW (E) 091052 is 47.0 ± 2.0 nmol/L. The preparation process of human serum matrix-based reference material and the lack of these type of secondary (commutable) reference material of unconjugated estriol lead to the interruption of its traceability chain, which is a problem to be solved in its standardization as mentioned in the metrological traceability in ISO 17511, 2020.


Assuntos
Estriol , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Humanos , Técnica de Diluição de Radioisótopos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos
6.
Ann Clin Lab Sci ; 52(1): 154-160, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35181629

RESUMO

OBJECTIVE: Adenosine deaminase (ADA) plays a major role in maintaining metabolic homeostasis via catalysis of hydrolytic deamination of adenosine to inosine. The ADA1 isoenzyme of ADA is an analyte tested in clinical laboratories; however, lack of quality control (QC) material in terms of enzyme homogeneity, stability, and coverage of the clinically relevant analytical measurement range (AMR), poses a challenge for adequate monitoring of this analyte. The aim of this study was to address the need for manufacture of QC material through recombinant expression of catalytically active ADA1 in eukaryotic cells (Pichia pastoris GS115). METHODS: The coding region of ADA1 gene was amplified by PCR and ligated into plasmid pPICZαA, followed by transfer into P. pastoris using electroporation. Recombinant ADA1 produced by P. pastoris was purified using a Ni-NTA resin column, yielding 5 mL of purified ADA1 with an activity of 4200.6 U/L. Purified ADA1 protein was added to human donor serum as the appropriate matrix for QC materials preparation. RESULTS: One hundred vials of lyophilized ADA1 were prepared at clinically significant concentrations at 41.6 U/L and 115.5 U/L (50 vials each). Both concentrations were homogenous and stable at room temperature (RT, 22-24°C) for at least 7 d, at 4°C for 3 months, and at -20°C for 12 months. Reconstituted aliquots of QC material were found to be stable at -20°C for up to 60 d and should be used within 8 h or 48 h when stored at RT or 4°C, respectively. CONCLUSION: Success of this ADA1 expression system presents a potential solution to increase production options available to clinical laboratories.


Assuntos
Adenosina Desaminase , Saccharomycetales , Adenosina Desaminase/biossíntese , Adenosina Desaminase/genética , Humanos , Laboratórios Clínicos , Controle de Qualidade , Saccharomycetales/genética , Saccharomycetales/metabolismo
7.
Anal Bioanal Chem ; 413(17): 4471-4481, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34018033

RESUMO

Accurate quantitation of aldosterone is clinically important in standardized testing for primary aldosteronism. The results are often variable when performed by clinical immunoassays. To standardize and ensure the accuracy of clinical systems, reference measurement procedures (RMPs) with higher metrological order are required. A simple and reliable isotope dilution LC-IDMS/MS-based measurement procedure for human plasma aldosterone has been developed. This method involved plasma spiked with a deuterium-labelled internal standard, equilibrated for 0.5 h, and extracted by liquid-liquid extraction (LLE) without derivatization. Aldosterone and its structural analogues were baseline separated with a C18-packed UHPLC column with gradient elution within 7 min. The signal intensity variability and measurement imprecision were reduced by bracketing calibration during plasma aldosterone value assignment. The limit of detection (LoD) was 19.4 pmol/L with a signal-to-noise ratio (S/N) > 3. The lowest limit of quantification (LLoQ) was 27.7 pmol/L (S/N > 10 and CV < 10.0%). LLE was performed with 1 mL of n-hexane/ethyl acetate (3:2, v/v), and the extraction recovery was determined to be 92.15 ± 3.54%. The imprecisions were ≤ 3.18% for samples at 124.8, 867.0, and 2628.5 pmol/L. The recoveries were 98.11-101.61%. The relative bias between this candidate RMP and the established RMP was 2.76-1.89%. The linearity response ranged from 27.7 to 2774.4 pmol/L with R2 = 0.999. The method performance met the requirements of RMPs (≤ 5% total CV and ≤ 3% bias). Furthermore, the developed method was applied to evaluate immunoassays through 41 patient sample comparisons. The calibration and measurement capability (CMC) of this method were also evaluated by measuring these samples. The candidate RMP can serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials. Selected ion chromatograms by LC-MS/MS using a C18 column for aldosterone and its structural analogues.


Assuntos
Aldosterona/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Técnicas de Diluição do Indicador , Isótopos/sangue , Limite de Detecção , Extração Líquido-Líquido/métodos
8.
Clin Lab ; 67(3)2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33739036

RESUMO

BACKGROUND: The aim of this study is to verify the analytical performance of four homocysteine detection systems made in China and to explore the comparability of homocysteine detection systems by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) reference method. METHODS: The intra-batch precision, inter-batch precision, accuracy, and linear range of four homocysteine detection systems were evaluated. The ID-LC-MS/MS reference method was used to evaluate the comparability and accuracy of fresh frozen serum samples in four different detection systems of homocysteine. The ID-LC-MS/MS reference method is used to assign samples as calibrators to calibrate each system. The variation and deviation of fresh serum samples between different systems before and after calibration were compared. RESULTS: The intra-batch imprecision of the four detection systems was less than 5%, and the coefficient of variation of inter-batch imprecision was less than 6.7%. The precision met the clinical requirements. Before calibration, the results measured by detection system 2 are consistent with the ID-LC-MS/MS reference method, which meets the requirements of accuracy verification. The regression equation of R² ≥ 0.975 in the regression equation of linear analysis of the four systems, the linearity of the four detection systems is good in the range of evaluation concentration, and all of them can meet the declared linear range. The absolute average bias of fresh serum measured by the four detection systems after calibration decreased from 3.76 µmol/L, 0.96 µmol/L, 1.30 µmol/L, -1.56 µmol/L to 0.31 µmol/L, 0.28 µmol/L, 0.4 µmol/L, 0.40 µmol/L, respectively. The relative average bias decreased from 22.6%, 7.50%, 11.0% and -8.50% to 1.98%, 1.78%, 2.59%, 2.34%, respectively. After calibration, the slope and intercept of the regression curve of the fresh serum measured by the four detection systems and the reference method are closer to 1 and 0 than before calibration. CONCLUSIONS: The precision, reference interval, and linear evaluation of the four detection systems are good. The ID-LC-MS/MS reference method assigning fresh frozen serum samples as calibrators can improve the accuracy and comparability of the results of different detection systems.


Assuntos
Homocisteína , Espectrometria de Massas em Tandem , Calibragem , China , Cromatografia Líquida , Humanos
9.
Ground Water ; 54(4): 569-78, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26728919

RESUMO

There can be marked variations in soil hydraulic properties in a soil vertical profile from the soil surface to the base of the root zone. Many existing two-layer soil moisture (TLSM) models cannot well describe typical stratified soil profiles. A modified TLSM model is presented in this study. The modified model results and those from two existing models are compared with field observations. The modified TLSM model had the best agreement with the field observations. In both the surface layer and the root zone layer, the root mean square errors of soil moisture estimated by the modified model were smaller than those for the other models. The parameters in the modified TLSM model are relatively easy to determine. The modified TLSM model offers clear advantages over current TLSM models.


Assuntos
Água Subterrânea , Solo , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...