Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Opt Lett ; 47(21): 5505-5508, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37219255

RESUMO

We present the results of experimental investigations of terahertz radiation generation conversion efficiency in an OH1 nonlinear organic crystal pumped by femtosecond laser pulses at 1240 nm wavelength. An influence of OH1 crystal thickness on the terahertz generation by optical rectification method was studied. It is shown that the optimal crystal thickness for the maximum conversion efficiency is 1 mm, which agrees with the previously made theoretical estimates.

2.
Opt Express ; 29(16): 26093-26102, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-34614922

RESUMO

We report the results of experimental studies and numerical simulation of the dynamics of the electron-hole pairs formation in silicon under the action of a two-period terahertz pulse with a maximum electric field strength of up to 23 MV/cm. It is shown that an inhomogeneous distribution of the charge carrier concentration over the depth of the silicon sample is formed, which persists for several microseconds. This inhomogeneity is formed due to a sharp increase in the rate of filling the conduction band with free carriers in the subsurface input layer of the silicon wafer, which occurs at a field strength above 15 MV/cm.

3.
Opt Express ; 28(23): 33921-33936, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33182871

RESUMO

The ideal laser source for nonlinear terahertz spectroscopy offers large versatility delivering both ultra-intense broadband single-cycle pulses and user-selectable multi-cycle pulses at narrow linewidths. Here we show a highly versatile terahertz laser platform providing single-cycle transients with tens of MV/cm peak field as well as spectrally narrow pulses, tunable in bandwidth and central frequency across 5 octaves at several MV/cm field strengths. The compact scheme is based on optical rectification in organic crystals of a temporally modulated laser beam. It allows up to 50 cycles and central frequency tunable from 0.5 to 7 terahertz, with a minimum width of 30 GHz, corresponding to the photon-energy width of ΔE=0.13 meV and the spectroscopic-wavenumber width of Δ(λ-1)=1.1 cm-1. The experimental results are excellently predicted by theoretical modelling. Our table-top source shows similar performances to that of large-scale terahertz facilities but offering in addition more versatility, multi-colour femtosecond pump-probe opportunities and ultralow timing jitter.

4.
Opt Express ; 27(19): 27273-27281, 2019 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-31674592

RESUMO

A versatile table-top high-intense source of terahertz radiation, enabling to generate pulses of both broadband and narrowband spectra with a tunable frequency up to 3 THz is presented. The terahertz radiation pulses are generated by optical rectification of femtosecond pulses of Cr:forsterite laser setup in nonlinear organic crystal OH1. Electric field strengths of broadband and narrowband terahertz pulses were achieved close to 20 MV/cm and more than 2 MV/cm, correspondingly. Experiments on excitation of spin subsystem oscillations of an antiferromagnetic NiO were carried out. Selective excitation of 0.42 THz mode was observed for the first time at room temperature by a narrowband terahertz pulses tuned close to mode frequency.

5.
Opt Lett ; 44(17): 4099-4102, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31465338

RESUMO

We present the experimental data on the direct measurements of spatial distribution of the terahertz (THz) pulse intensity profile using a commercial silicon-based charge-coupled device (CCD) camera in the spectral range from 1-3 THz. A method to measure the dimensions of a high-intensity THz radiation beam in the focal plane using the CCD camera is proposed and experimentally verified.

6.
Sci Rep ; 9(1): 9753, 2019 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-31278349

RESUMO

The experimental findings on the second harmonic generation (SHG) in centrosymmetric crystal silicon are reported. The SHG is induced by extremely high electric field (up to 15 MV/cm) parallel to the crystal surface of a short terahertz (THz) pulse while probing by an infrared femtosecond optical pulse. The SHG under such unique conditions is reported for the first time. At the electric field amplitude above 8 MV/cm, the quadratic dependence of the SHG yield integrated over the THz pulse duration on the electric field is violated and SHG yield is not changed with a further increase of the THz field. Saturation of SHG intensity at high electric fields is explained in terms of carrier density increase due to impact ionization and destructive interference of electric-field induced and current induced nonlinear polarizations.

7.
Appl Opt ; 58(14): 3815-3822, 2019 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-31158195

RESUMO

A novel computer 3D model is presented for calculations of optical parameters (transmittance, reflectance, and absorbance) of a metal-knitted mesh textile as a structural element of deployable antenna reflectors for space satellites. The model is based on geometrical-optics ray tracing upon diffuse scattering of a broadband light source (Sun) at a complex knitted mesh structure with different inclinations to the radiative source. The proposed computer model is built for the special type of metal-wire textile (two-bar large void tricot) possessing extremely high transmittance and is verified by comparison with the experimental measurements of light scattering parameters of real antenna mesh samples of data-relaying satellites (Russian series "Loutch"). The model is used for calculations of solar radiation pressure exerted on a knitted mesh antenna reflector and gives the maximal pressure value of about 0.28 µN/m2.

8.
Phys Rev Lett ; 120(8): 085704, 2018 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-29543009

RESUMO

We report on the experimental observation of high-power terahertz-radiation-induced damage in a thin aluminum film with a thickness less than a terahertz skin depth. Damage in a thin metal film produced by a single terahertz pulse is observed for the first time. The damage mechanism induced by a single terahertz pulse could be attributed to thermal expansion of the film causing debonding of the film from the substrate, film cracking, and ablation. The damage pattern induced by multiple terahertz pulses at fluences below the damage threshold is quite different from that observed in single-pulse experiments. The observed damage pattern resembles an array of microcracks elongated perpendicular to the in-plane field direction. A mechanism related to microcracks' generation and based on a new phenomenon of electrostriction in thin metal films is proposed.

9.
Opt Lett ; 42(23): 4889-4892, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29216136

RESUMO

The results of high-field terahertz transmission experiments on n-doped silicon (carrier concentration of 8.7×1016 cm-3) are presented. We use terahertz pulses with electric field strengths up to 3.1 MV cm-1 and a pulse duration of 700 fs. A huge transmittance enhancement of ∼90 times is observed with increasing of the terahertz electric field strengths within the range of 1.5-3.1 MV cm-1.

10.
Ontogenez ; 48(1): 63-72, 2017.
Artigo em Russo | MEDLINE | ID: mdl-30277222

RESUMO

In this study, modern techniques of laser microsurgery of cell spheroids have been used to develop a new simple, reproducible model for studying the mechanisms of repair and regeneration in vitro. Nanosecond laser pulses were applied to perform a microdissection of the outer and the inner zones of the spheroids from dermal fibroblasts. To achieve effective dissection and preservation of spheroid viability, the optimal parameters were chosen: 355 nm wavelength, 100 Hz frequency, 2 ns pulse duration, laser pulses in the range of 7­9 µ J. After microdissection, we observed injury of the spheroids : the edges of the wound surface opened and the angular opening reached a value of more than 180°. As early as during the first hour after spheroid microdissection with laser radiation, the surviving cells changed their shape: cells on the spheroid surface and directly in the damaged area became rounded. One day after microdissection, the structure of the spheroids began to partially recover, the cells in the surface layers began to take the original flattened shape; debris of dead damaged cells and their fragments was gradually cleared from the spheroid composition. In the proposed model, the first data on stimulation of structure recovery of injured spheroids from dermal fibroblasts with a P199 synthetic polypeptide, which is used in cosmetology for the initiation of antiaging and regenerative effects in the skin, were received. After microdissection, recovery of the spheroids structure with a few surface layers of flattened imbricated arranged cells and polygonal cells of the inner zone in the presence of P199 peptide was faster than in the control group, and was completed within 7 days, presumably due to the remodeling of the survived cells.


Assuntos
Terapia a Laser/métodos , Microcirurgia/métodos , Modelos Biológicos , Regeneração , Esferoides Celulares/metabolismo , Humanos , Terapia a Laser/instrumentação , Microcirurgia/instrumentação , Esferoides Celulares/citologia
11.
Biol Open ; 5(7): 993-1000, 2016 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27334698

RESUMO

Modern techniques of laser microsurgery of cell spheroids were used to develop a new simple reproducible model for studying repair and regeneration in vitro Nanosecond laser pulses (wavelength 355 nm, frequency 100 Hz, pulse duration 2 ns) were applied to perform a microdissection of the outer and the inner zones of human bone marrow multipotent mesenchymal stromal cells (BM MMSC) spheroids. To achieve effective dissection and preservation of spheroid viability, the energy of laser pulses was optimized and adjusted in the range 7-9 µJ. After microdissection, the edges of the wound surface opened and the angular opening reached a value of more than 180°. The destruction of the initial spheroid structure was observed in the wound area, with surviving cells changing their shape into a round one. Partial restoration of a spheroid form took place in the first six hours. The complete structure restoration accompanying the reparative processes occurred gradually over seven days due to remodelling of surviving cells.

12.
Artigo em Russo | MEDLINE | ID: mdl-28091496

RESUMO

Clinical characteristics of neurological forms of hepatolenticular degeneration (HLD) were studied in one of the regions of Russia (Primorsky Krai) in the sample of 111 patients at the wide age range (average 35.6 years); mean time since the diagnosis was 13.7 years. According to N.V. Konovalov's classification, 4 groups of patients were identified: I arrhythmic-hyperkinetic form (n=61), II extra-pyramidal cortical form (n=30), III tremulous form (n=15), IV tremulous-rigid form (n=6). A main body of clinical manifestations of the pathology at the stage of cerebral signal of HLD manifestation was determined; three degrees of the severity of its course were established. Correlation between clinical HLD manifestation severityand the time since the diagnosis of neurological stage of the disease and its form was noted. Age parameters of the development of different extra-pyramidal disturbances and predictors of the severity of the course were specified.


Assuntos
Degeneração Hepatolenticular , Adulto , Progressão da Doença , Degeneração Hepatolenticular/diagnóstico , Degeneração Hepatolenticular/patologia , Humanos , Federação Russa , Índice de Gravidade de Doença , Fatores de Tempo
13.
Opt Express ; 23(4): 4573-80, 2015 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-25836494

RESUMO

We investigated Terahertz generation in organic crystals DSTMS, DAST and OH1 directly pumped by a Cr:forsterite laser at central wavelength of 1.25 µm. This pump laser technology provides a laser-to-THz energy conversion efficiency higher than 3 percent. Phase-matching is demonstrated over a broad 0.1-8 THz frequency range. In our simple setup we achieved hundred µJ pulses in tight focus resulting in electric and magnetic field larger than 10 MV/cm and 3 Tesla.

14.
Radiats Biol Radioecol ; 55(5): 467-73, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26863776

RESUMO

The characteristic of medical and dosimetric register database of Siberian Group of Chemical Enterprises personnel is represented. This characteristic includes the description of the database structure, main sources of information, quantitative composition of the cohort under study, methods of evaluation of the external and internal irradiation doses, modern data on cancer incidence and reasons of death. The database is the basis for estimating the risk of the cancer and non-cancer effects after a long-term radiation exposure and dependence of "dose-response" at different levels: from population and group to cell and molecular. Now the database of register contains the information about more than 66,500 employees at the Siberian Group of Chemical Enterprises, about 22,000 of whom were exposed to external irradiation and more than 7500 employees--to internal irradiation. The register is the information resource of a large biological material bank. Using this bank, the research of chronic radiation exposure genetic effects and markers of individual radio sensitivity is performed.


Assuntos
Bases de Dados Factuais , Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação/epidemiologia , Humanos , Lesões por Radiação/genética , Lesões por Radiação/fisiopatologia , Radiação Ionizante , Radiometria , Federação Russa , Sibéria
15.
Opt Lett ; 39(23): 6632-5, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25490639

RESUMO

We report on high-field terahertz transients with 0.9-mJ pulse energy produced in a 400 mm² partitioned organic crystal by optical rectification of a 30-mJ laser pulse centered at 1.25 µm wavelength. The phase-locked single-cycle terahertz pulses cover the hard-to-access low-frequency range between 0.1 and 5 THz and carry peak fields of more than 42 MV/cm and 14 Tesla with the potential to reach over 80 MV/cm by choosing appropriate focusing optics. The scheme based on a Cr:Mg2SiO4 laser offers a high conversion efficiency of 3% using uncooled organic crystal. The collimated pump laser configuration provides excellent terahertz focusing conditions.

18.
Voen Med Zh ; 333(7): 22-7, 2012 Jul.
Artigo em Russo | MEDLINE | ID: mdl-23038956

RESUMO

The tendency of psychogenetic neurological disorders increases with predominance in young persons being students of high schools, students of military, technical and other lyceum was shown. The origin of diseases are psychotraumas (family, work), stress. Also genetic and hereditary factors take place that are indicative for individual rehabilitation organization. The basics of psychosomatic diseases pathogenesis are the disintegration mechanisms in brain structure activity,the disorders of integrative apparatus which provides the relationship between somatic, emotional and vegetative functions. The confirmation of brain work disintegration is achieved by modern computer diagnostic systems. As psychogenic diseases increase the need in methods of computer electroencephalography, evoked potentials, and rheoencephalography application is more actual.


Assuntos
Diagnóstico por Computador , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/fisiopatologia , Estresse Fisiológico , Adolescente , Adulto , Encéfalo/fisiopatologia , Eletrocardiografia , Humanos , Masculino , Doenças do Sistema Nervoso/epidemiologia , Doenças do Sistema Nervoso/etiologia
20.
Bull Exp Biol Med ; 151(1): 154-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-22442822

RESUMO

Practical advantages of using femtosecond laser pulses for manipulations in cell surgery were demonstrated. The use of femtosecond laser pulses enables precision punching of the zona pellucida of the embryo without damaging its cells. With the help of femtosecond laser tweezers/scalpel, auxillary laser hatching was performed and a technique of optical biopsy of mammalian embryo was developed, which enabled non-contact sampling of embryonic material for preimplantation diagnostics. Our findings suggest that about 90% embryos retained the ability to develop at least to the blastula stage after this manipulation.


Assuntos
Lasers , Microcirurgia/métodos , Pinças Ópticas/efeitos adversos , Diagnóstico Pré-Implantação/métodos , Animais , Biópsia , Embrião de Mamíferos , Feminino , Camundongos , Microscopia , Microcirurgia/instrumentação , Gravidez , Diagnóstico Pré-Implantação/instrumentação , Zona Pelúcida/ultraestrutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...