1.
J Am Soc Echocardiogr ; 14(11): 1107-11, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11696836

RESUMO

The Doppler-derived mean mitral valve gradient (DeltaP(M)) based on the simplified Bernoulli equation requires computerized integration of the Doppler signal and evaluation by a technician with the use of special equipment. We have noted empirically that the DeltaP(M) can be derived by the equation DeltaP(M) = (P(P) - P(T)) / 3 + P(T). Peak (P(P)) and trough (P(T)) pressures are derived from the simplified Bernoulli equation (P = 4V(2)). This equation can be used by the experienced observer to calculate the mean mitral valve gradient without specialized equipment. The purpose of this study is to validate the above empirically derived equation in patients with mitral stenosis. We retrospectively reviewed 41 consecutive studies done at our institution from October 1, 1997, through September 30, 1998, in which mean mitral valve gradient was assessed. Each study was reviewed and the DeltaP(M), P(P), and P(T) were measured for 3 beats by using the software package on an HP Sonos 2500. DeltaP(M) was also calculated with our formula. A linear regression model was used to compare the results of the measured versus the calculated DeltaP(M). The following sub-categories were also evaluated: transthoracic studies (TTE), transesophageal studies (TEE), native valve gradients (NV), prosthetic valve gradients (PV), sinus rhythm (SR), and atrial fibrillation (AF). The results of the regression analysis of the entire population of mean versus calculated DeltaP(M) are n = 41, r = 0.99, P <.001, and standard error of the estimate (SEE) = 0.67. The regression results for the subgroups are as follows: TTE: n = 30, r = 0.99, P <.001, SEE = 0.51; TEE: n = 11, r = 0.99, P <.001, SEE = 59; NV: n = 26, r = 0.99, P <.001, SEE = 0.59; PV: n = 15, r = 0.98, P <.001, SEE = 0.84; SR: n = 23, r = 0.99, P <.001, SEE = 0.58; and AF: n = 18, r = 0.98, P <.001, SEE = 0.82. In conclusion, the simple formula that we have derived is an accurate method for calculation of mean mitral valve gradient, and it is accurate over multiple subgroups. Furthermore, the formula allows visual verification of mean mitral gradient without specialized software.


Assuntos
Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Matemática , Pessoa de Meia-Idade , Valva Mitral/patologia , Estenose da Valva Mitral/fisiopatologia , Análise de Regressão , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador
2.
Clin Cardiol ; 22(6): 426-8, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10376185

RESUMO

Exercise testing is commonly performed to assess the functional result of coronary revascularization procedures and is usually not associated with any complications. However, this report documents a rare case of coronary dissection and thrombosis, which resulted in an acute myocardial infarction, in a patient who underwent stress testing 3 months following successful coronary stent implantation.


Assuntos
Angioplastia Coronária com Balão , Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Trombose Coronária/etiologia , Teste de Esforço , Infarto do Miocárdio/etiologia , Idoso , Dissecção Aórtica/diagnóstico , Angioplastia Coronária com Balão/efeitos adversos , Aneurisma Aórtico/diagnóstico , Angiografia Coronária , Trombose Coronária/diagnóstico , Eletrocardiografia , Teste de Esforço/efeitos adversos , Humanos , Masculino , Infarto do Miocárdio/diagnóstico , Stents , Tomografia Computadorizada de Emissão de Fóton Único
4.
J Am Soc Echocardiogr ; 9(5): 663-7, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8887869

RESUMO

Mycotic aneurysms of the aorta are prone to rupture. Thus rapid and accurate diagnosis is essential so that surgical repair can be undertaken. We report a case of mycotic aortic aneurysm caused by mitral valve endocarditis. The aneurysm situated at the junction of the thoracoabdominal aorta was readily detected by transesophageal echocardiography. Computed tomography and aortography were complementary to transesophageal echocardiography in establishing the diagnosis. The patient underwent successful repair and acute inflammation of the aneurysm was present at histologic examination.


Assuntos
Aneurisma Infectado/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Infecções Estreptocócicas/diagnóstico por imagem , Aortografia , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
6.
J Am Soc Echocardiogr ; 8(6): 874-8, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8611287

RESUMO

Continuous-wave Doppler echocardiography of aortic flow velocity has a variety of clinical and research applications. Recently, continuous-wave Doppler echocardiography has been added to transesophageal echocardiographic systems. However, alignment of the Doppler beam with aortic flow is not possible with standard single and biplane views. A modified transesophageal echocardiographic view; the transgastric five-chamber (TG5C) view, allows for measurement of aortic flow velocity but its feasibility and accuracy in an unselected consecutive population have not yet been described. The feasibility of obtaining the TG5C view and measuring aortic flow velocity was assessed in 58 consecutive transesophageal echocardiographic investigations. The TG5C view was obtained in 97% and adequate Doppler flow velocity signals were obtained in 91% of patients. The accuracy of measurements was assessed in 24 patients in whom flow signals from both the TG5C and standard transthoracic views could be obtained. The correlation between TG5C and transthoracic views was excellent, with r values of 0.968 and 0.952 for peak aortic flow velocity and mean aortic flow velocity, respectively. Accurate aortic flow velocity measurements can be obtained in most patients during transesophageal echocardiography with the TG5C view. This view has great utility in a variety of situations in which adequate transthoracic imaging is not possible, especially the operating room and intensive care unit.


Assuntos
Valva Aórtica/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Adolescente , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Criança , Ecocardiografia Doppler/métodos , Estudos de Viabilidade , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
7.
J Am Soc Echocardiogr ; 8(6): 933-7, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8611296

RESUMO

We present an unusual case of biopsy-proven myocardial sarcoidosis in which the transthoracic and transesophageal echocardiographic findings suggested metastatic tumor involvement of the myocardium and pericardium. The pathologic, clinical, and echocardiographic features of cardiac sarcoidosis are reviewed, with emphasis on the role of echocardiography.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Ecocardiografia , Neoplasias Cardíacas/diagnóstico por imagem , Sarcoidose/diagnóstico por imagem , Adulto , Diagnóstico Diferencial , Ecocardiografia/métodos , Ecocardiografia Transesofagiana , Feminino , Neoplasias Cardíacas/secundário , Humanos , Pericárdio/diagnóstico por imagem
8.
Z Kardiol ; 84(4): 264-9, 1995 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-7785297

RESUMO

The risk of valve-related complications and the necessity of anticoagulation in patients with prosthetic valves, has led to new operative techniques in the correction of severe aortic insufficiency. In the last 2 years, 35 patients (mean age 41.3 years, range 10-80 years) with aortic insufficiency underwent reconstructive valves surgery. Eighteen patients had a commissuroplasty with or without triangular resection. In 5 patients with perforation, the valves could be reconstructed with a pericardial patch. In 12 patients with insufficiency due to aortic aneurysm, the valves were resuspended within the aortic prosthesis. In 2 patients the aortic valves were replaced intraoperatively because of unsatisfactory results. The perioperative mortality was 5.7%. The echocardiographic degree of aortic insufficiency decreased from 3.3 +/- 0.5 preoperatively to 0.45 +/- 0.53 postoperatively. Two patients were reoperated within the first week. Five of 23 patients at 1-year follow-up have mild to moderate aortic insufficiency. Mean ventricular dimensions and function at discharge and after 1-year follow-up are normal. With the new operative techniques described recently, valve-sparing corrections of aortic insufficiency are possible in an increasing number of patients, and autologous valve tissue can be saved. With more refinement of surgical technique, early postoperative results will further improve.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Prótese Vascular , Volume Cardíaco/fisiologia , Criança , Ecocardiografia , Feminino , Seguimentos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/transplante , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Reoperação , Função Ventricular Esquerda/fisiologia
9.
Eur Heart J ; 16(3): 402-5, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7789384

RESUMO

In the present study, biplane transoesophageal echocardiography (TEE) was scheduled as part of an aneurysm surveillance programme during routine ambulatory follow-up of 37 patients following aortic aneurysm surgery. Time from surgery ranged from 3-72 months. Twenty-two patients had had aortic dissection and 15 non-dissecting aneurysms. Nineteen patients received an interposition graft of the ascending aorta, 12 valved conduit and six an interposition graft of the descending thoracic aorta. TEE showed enlargement of the sinus of Valsalva > 45 mm in seven patients. Dilatation > 45 mm of one or more aortic segments was found in four patients. An intimal flap was present in all patients, with primary aortic dissection if the initial dissection extended beyond the replaced segment. This was the case in 17 of 22 patients with aortic dissection. One to four intimal tears were identified in 15 of these patients. In all patients with intimal tears, flow was detected by colour flow Doppler in the false lumen. Thrombus formation was nil or minimal in the false lumen in 12 patients. TEE significantly influenced further management in 14 of 37 patients (38%). More frequent follow-up was scheduled in eight patients. Aortic surgery was performed electively for the second or third time in six patients based on TEE findings. We conclude that after surgical repair of aortic aneurysm, the incidence of pathological findings by TEE is high. These may have significant influence on further patient management and emphasize the need for careful follow-up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Prótese Vascular , Ecocardiografia Transesofagiana , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler em Cores , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Reoperação
10.
Anaesthesia ; 49(5): 432-7, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8209989

RESUMO

Fourteen patients with severe hypotension and adult respiratory distress syndrome after trauma (n = 7), general surgery (n = 6) or burns (n = 1) were studied. After volume loading with 6 ml.kg-1 hydroxyethyl starch over 30 min (time I), dobutamine was infused intravenously at 5 micrograms.kg-1.min-1 (time II) and 10 micrograms.kg-1.min-1 (time III). A 5 MHz transoesophageal echocardiographic probe was used to image a standard transgastric short axis view of the left ventricle. Haemodynamic data were obtained from thermodilution studies using pulmonary flotation catheterisation. Echocardiographic measurements (off-line from videotape) and qualitative visual assessment of left ventricular function (visual assessment, on-line) were performed. All measurements were made after fluid replacement, and during infusion of the two dobutamine doses. An improvement in mean systemic arterial blood pressure and mean stroke volume occurred from time I to the end of dobutamine infusion (p < 0.05). All patients, after volume infusion, were normovolaemic according to transoesophageal echocardiography and there was a good correlation between end-diastolic area and stroke volume (r = 0.73). During dobutamine infusion, echocardiographic measurements showed no significant dose-related increase in mean (SD) percentage left ventricular short axis area change from baseline after hydroxyethyl starch (time I: 60 (2); time II: 63 (2); time III: 64 (2)). However, a significant increase in short axis area change was seen in nine of the 14 patients (67%). Analysis of the end-diastolic area/short axis area change relationship revealed a heterogeneous response to dobutamine.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cateterismo Cardíaco , Dobutamina/uso terapêutico , Ecocardiografia Transesofagiana , Hemodinâmica/efeitos dos fármacos , Síndrome do Desconforto Respiratório/tratamento farmacológico , Adulto , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/tratamento farmacológico , Síndrome do Desconforto Respiratório/diagnóstico por imagem
11.
Eur J Emerg Med ; 1(1): 19-26, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9422132

RESUMO

In addition to the invasive haemodynamic monitoring procedures, an on-line assessment of cardiac performance by means of transoesophageal echocardiography might have a certain role in small volume resuscitation of patients with acute respiratory failure or Adult Respiratory Distress Syndrome (ARDS). The goal of this investigation was therefore to determine the effects of a hypertonic hyperoncotic solution, hypertonic hydoxyethl-starch (HHES), (HHES = HES [200.000/0.6-0.66; 60 g l-1; Leopold, Graz; Austria] combined with NaCl [75 g l-1) on haemodynamics and cardiac performance using the transoesophageal echocardiography. After institutional approval we investigated 23 patients suffering from septic ARDS after trauma or major surgery during four periods of resuscitation. Phase I = control values after infusion of 20 ml kg-1 crystalloid solution, phase II = 50% hypertonic hydroxyethyl-starch solution (2 ml kg-1), phase III = at the end of HHES (4 ml kg-1), IV = 30 min after the end of HHES. Before HHES-infusion, all patients showed arterial hypotension with mean arterial pressures of 64 +/- 2 mmHg. The infusion of 2 ml kg-1 HHES resulted in a significant increase of systemic and pulmonary arterial pressures over the study period. A significant improvement in cardiac output was associated with increasing stroke volumes, oxygen delivery and oxygen consumption (see Tables 1 and 2). Small volume resuscitation also resulted in significant increases of endsystolic and endiastolic left ventricular areas and the corresponding calculated wall stress (Figs 1-3). We conclude from our preliminary data that when using HHES, only modest fluid resuscitation was sufficient to restore adequate preload and oxygen delivery in patients with sepsis-related acute respiratory failure.


Assuntos
Hemodinâmica/efeitos dos fármacos , Derivados de Hidroxietil Amido/administração & dosagem , Substitutos do Plasma/administração & dosagem , Síndrome do Desconforto Respiratório/terapia , Ressuscitação/métodos , Função Ventricular Esquerda/efeitos dos fármacos , Adolescente , Adulto , Idoso , Análise de Variância , Relação Dose-Resposta a Droga , Ecocardiografia Transesofagiana , Feminino , Humanos , Soluções Hipertônicas/administração & dosagem , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Consumo de Oxigênio/efeitos dos fármacos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/etiologia , Ressuscitação/instrumentação , Síndrome de Resposta Inflamatória Sistêmica/complicações , Resultado do Tratamento
12.
Thorac Cardiovasc Surg ; 42(1): 29-31, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8184390

RESUMO

Surgical advances and the introduction of new more rapid and accurate diagnostic techniques have led to significant improvement in the survival of patients with aortic aneurysms. However, considerable long-term morbidity and mortality remains a concern. In the present study we report on the occurrence of sinus of Valsalva (SV) aneurysm after repair of the ascending aorta for aortic dissection as a significant long-term complication. Since transesophageal echocardiography (TEE) became available it has been used for the follow-up of 33 hospital survivors after ascending aortic replacement for a mean of 27 +/- 20 months. Those patients who received a valved conduit were excluded from this analysis. The aortic valve was conserved in 22 patients: 17 had a dissecting aneurysm involving the ascending aorta and 4 patients non-dissecting aneurysms. A sinus of Valsalva diameter > 45 mm was considered an aneurysm and was found in a total of 7 patients (33%), 5 being patients with aortic dissection. The overall reoperation rate on account of SV aneurysms was 24%. We conclude that SV aneurysm is a significant long-term complication of patients after repair of the ascending aorta. In the light of these results we have changed our operative policy of repair to include resorcin glue as a reinforcing agent or to perform more extensive repair.


Assuntos
Aneurisma Aórtico/etiologia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Seio Aórtico , Prótese Vascular , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias
13.
J Thorac Cardiovasc Surg ; 103(6): 1113-7; discussion 1117-8, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1597975

RESUMO

The diagnostic accuracy and benefit of transesophageal echocardiography were investigated in 32 patients with suspected aortic dissection. Results of transesophageal echocardiography were compared with surgical assessment. The Stanford classification was used for differentiation of dissection type. Examination time was 5 to 15 minutes. Twenty-eight patients were correctly identified to have aortic dissection; four patients had nondissecting aneurysms of the ascending aorta. Both sensitivity and specificity for detection of aortic dissection were 100%. Type of dissection was misdiagnosed in one patient. Classification of dissection type was correct in 96%. The primary entry site was correctly identified in 25 patients (89%). Aortic regurgitation was found in 57% of patients. Pericardial effusion was detected in 21%, with tamponade in one patient. Myocardial infarction was suggested by transesophageal echocardiography in 7%, and 14% had significantly reduced left ventricular function. Eight patients underwent operation based on transesophageal echocardiography alone. Intraoperative transesophageal echocardiography, performed in 20 patients, verified retrograde flow in the true lumen after femoral cannulation. Transesophageal echocardiography documented postrepair persistence of the intimal flap in aortic segments that were not operated on in all patients. Secondary tears and flow in the false lumen were detected in 35% of patients. We conclude that transesophageal echocardiography allows expedient and accurate diagnosis and classification of aortic dissection, and we recommend it as the primary bedside diagnostic modality. It can especially identify patients requiring surgical intervention without further delay caused by other diagnostic procedures.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Ecocardiografia Doppler/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aneurisma Aórtico/complicações , Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia Doppler/instrumentação , Emergências , Esôfago , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Sensibilidade e Especificidade
14.
J Heart Lung Transplant ; 11(2 Pt 1): 348-9, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1374266

RESUMO

Twenty patients undergoing orthotopic heart transplantation were randomized preoperatively to receive either the serine proteinase inhibitor aprotinin in a low dose (560 mg; n = 10) or a placebo (control group, n = 10) at the time of transplantation. Blood loss 24 and 48 hours after transplantation was significantly lower in the group treated with aprotinin (i.e., 510 ml vs 820 ml, p less than 0.01, and 690 ml vs 1000 ml, p less than 0.03, respectively. Accordingly, the aprotinin group required significantly less transfused blood in the first 48 postoperative hours 0 to 250 ml versus 0 to 1000 ml (p less than 0.04). Seventy percent of the patients treated with aprotinin underwent transplantation without the need of nonautologous blood, compared with only 30% in the control group.


Assuntos
Aprotinina/uso terapêutico , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Transplante de Coração , Cardiomiopatia Dilatada/cirurgia , Humanos , Masculino
15.
Acta Med Austriaca ; 19(5): 125-9, 1992.
Artigo em Alemão | MEDLINE | ID: mdl-1298139

RESUMO

Following the development of new techniques in echocardiography and especially of Doppler color flow imaging, a new dimension of cardiac surgery has been brought about. The use of transesophageal probes facilitates routine surgery to be performed without interferences and, also, comparability between repeated ultrasonic measurements. Originally, echocardiography was mainly applied for quality control by comparing pre- and postoperative echocardiograms. Now it is equally important in perioperative strategy planning guiding the surgeon's decision throughout the operation as well as in cardiac emergencies. Using intraoperative echocardiography routinely in cardiac surgery establishes a more and more close cooperation between surgeons, cardiologists, and anesthesiologists. In order to evaluate the clinical relevance of echo findings, they have to be repeatedly correlated to surgical realities and to long term results of clinical outcome.


Assuntos
Ecocardiografia Doppler , Ecocardiografia , Cardiopatias/cirurgia , Complicações Intraoperatórias/diagnóstico por imagem , Adulto , Criança , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Cardiopatias/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Humanos
16.
Clin Ther ; 13(2): 289-303, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1863944

RESUMO

The primary factor limiting the number of heart transplantation performed is the lack of adequate donor hearts. One of the main factors contributing to this is the relatively short period a donor heart can be preserved. Clinical studies demonstrate that ischemic times over five hours lead to early heart failure after transplantation. A considerable increase in preservation time would be necessary to enlarge the donor pool. In spite of intensive research, it is not yet possible to increase the preservation period above four hours, which was achieved in 1978. An increase of the cold ischemia period to more than four hours without the risk of transplanted heart damage may only be achieved by improving cardioplegic management.


Assuntos
Soluções Cardioplégicas/farmacologia , Coração , Preservação de Órgãos/métodos , Transplante de Coração , Humanos
17.
Eur J Cardiothorac Surg ; 5(9): 492-7, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1931094

RESUMO

Transesophageal echocardiography (TEE) has assumed an increasing importance in cardiothoracic surgery, but its use in patients with mechanically assisted circulation is unclear. We performed TEE in 11 patients: total artificial heart (TAH) 2, right ventricular assist device (RVAD) 2, left ventricular assist device (LVAD) 6, biventricular assist device (BVAD) 1. TEE was helpful in three areas. (1) selection of the assist device (AD): evaluation of left and right ventricular function allows differentiation of left, right or biventricular failure. (2) management of patient and optimization of pump performance: in all patients, correct cannula position and pump flow could be identified. Right ventricular failure in the presence of LVAD was found to cause hemodynamic instability in 4 patients. In 1 patient with repeated RV dilation and hypotension despite RVAD, TEE allowed optimal pump settings to be determined. (3) weaning from AD: Recovery of ventricular function can be assessed prior to weaning and repeatedly monitored during weaning. TEE in TAH is limited to problems such as identification of atrial thrombus or inflow valve dysfunction. We conclude that TEE is useful in the setting of mechanically assisted circulation for AD selection, improvement of patient management, optimization of pump performance and during weaning from AD.


Assuntos
Ecocardiografia/métodos , Coração Artificial , Coração Auxiliar , Circulação Assistida , Velocidade do Fluxo Sanguíneo , Débito Cardíaco , Baixo Débito Cardíaco/fisiopatologia , Cardiomiopatias/cirurgia , Ecocardiografia Doppler/métodos , Esôfago , Feminino , Transplante de Coração/reabilitação , Humanos , Cuidados Intraoperatórios , Masculino , Infarto do Miocárdio/cirurgia , Cuidados Pós-Operatórios , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita