Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 11(1): 4949, 2020 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-33009388

RESUMO

Electron microscopy (EM) is widely used for studying cellular structure and network connectivity in the brain. We have built a parallel imaging pipeline using transmission electron microscopes that scales this technology, implements 24/7 continuous autonomous imaging, and enables the acquisition of petascale datasets. The suitability of this architecture for large-scale imaging was demonstrated by acquiring a volume of more than 1 mm3 of mouse neocortex, spanning four different visual areas at synaptic resolution, in less than 6 months. Over 26,500 ultrathin tissue sections from the same block were imaged, yielding a dataset of more than 2 petabytes. The combined burst acquisition rate of the pipeline is 3 Gpixel per sec and the net rate is 600 Mpixel per sec with six microscopes running in parallel. This work demonstrates the feasibility of acquiring EM datasets at the scale of cortical microcircuits in multiple brain regions and species.


Assuntos
Processamento de Imagem Assistida por Computador , Microscopia Eletrônica de Transmissão , Rede Nervosa/ultraestrutura , Neurônios/ultraestrutura , Animais , Automação , Camundongos , Neocórtex/diagnóstico por imagem , Software
3.
PLoS One ; 8(7): e69058, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23935923

RESUMO

We present "molecular threading", a surface independent tip-based method for stretching and depositing single and double-stranded DNA molecules. DNA is stretched into air at a liquid-air interface, and can be subsequently deposited onto a dry substrate isolated from solution. The design of an apparatus used for molecular threading is presented, and fluorescence and electron microscopies are used to characterize the angular distribution, straightness, and reproducibility of stretched DNA deposited in arrays onto elastomeric surfaces and thin membranes. Molecular threading demonstrates high straightness and uniformity over length scales from nanometers to micrometers, and represents an alternative to existing DNA deposition and linearization methods. These results point towards scalable and high-throughput precision manipulation of single-molecule polymers.


Assuntos
Ar , DNA/química , Conformação de Ácido Nucleico , Soluções/química , DNA/ultraestrutura , DNA de Cadeia Simples/química , DNA de Cadeia Simples/ultraestrutura , Microscopia Eletrônica/métodos , Microscopia de Fluorescência/métodos , Reprodutibilidade dos Testes , Propriedades de Superfície , Tecnologia/instrumentação , Tecnologia/métodos
4.
Nature ; 464(7288): 571-4, 2010 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-20336141

RESUMO

Direct imaging and chemical identification of all the atoms in a material with unknown three-dimensional structure would constitute a very powerful general analysis tool. Transmission electron microscopy should in principle be able to fulfil this role, as many scientists including Feynman realized early on. It images matter with electrons that scatter strongly from individual atoms and whose wavelengths are about 50 times smaller than an atom. Recently the technique has advanced greatly owing to the introduction of aberration-corrected optics. However, neither electron microscopy nor any other experimental technique has yet been able to resolve and identify all the atoms in a non-periodic material consisting of several atomic species. Here we show that annular dark-field imaging in an aberration-corrected scanning transmission electron microscope optimized for low voltage operation can resolve and identify the chemical type of every atom in monolayer hexagonal boron nitride that contains substitutional defects. Three types of atomic substitutions were found and identified: carbon substituting for boron, carbon substituting for nitrogen, and oxygen substituting for nitrogen. The substitutions caused in-plane distortions in the boron nitride monolayer of about 0.1 A magnitude, which were directly resolved, and verified by density functional theory calculations. The results demonstrate that atom-by-atom structural and chemical analysis of all radiation-damage-resistant atoms present in, and on top of, ultra-thin sheets has now become possible.


Assuntos
Técnicas de Química Analítica , Microscopia Eletrônica/métodos , Compostos de Boro/química
5.
Philos Trans A Math Phys Eng Sci ; 367(1903): 3683-97, 2009 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-19687060

RESUMO

An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability comparable to systems using monochromators and spectrometers that are raised to near the high voltage of the instrument. It will also be able to correct the chromatic aberration of the probe-forming column. It should be able to provide variable energy resolution down to approximately 10 meV and spatial resolution less than 1 A.

6.
Ultramicroscopy ; 107(6-7): 543-50, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17240530

RESUMO

A 2-beam model is used to simulate precession electron diffraction (PED) intensities. It is shown that this model can be inverted with minimal knowledge of the underlying crystal structure, permitting structure factor amplitudes to be deduced directly from measured intensities within the 2-beam approximation. This approach may be used in conjunction with direct methods to obtain correct, kinematically interpretable structure indications for data sets from relatively thin crystals (less than approximately 400A), and an experimental example based on (Ga,In)(2)SnO(5) is presented. The failure of this approach at large thickness is illustrated by an additional data set for MFI zeolite. The 2-beam approximation provides a simple model for PED intensities, and inversion using this model shows advantages over a kinematical approximation. It is however too rough approximation to be of general use and ultimately it is to be hoped that more accurate models with similar ease of use can be derived to treat PED data.

7.
J Phys Chem B ; 109(22): 11158-62, 2005 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-16852361

RESUMO

A novel method to produce solution-phase triangular silver nanoparticles is presented. Ag nanoparticles are prepared by nanosphere lithography and are subsequently released into solution. The resulting nanoparticles are asymmetrically functionalized to produce either single isolated nanoparticles or dimer pairs. The structural and optical properties of Ag nanoparticles have been characterized. Mie theory and the Discrete Dipole Approximation method (DDA) have been used to model and interpret the optical properties of the released Ag nanoparticles.

8.
Microsc Microanal ; 10(1): 96-104, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15306071

RESUMO

Kinematical and two-beam calculations have been conducted and are compared to experimental precession data for the large unit cell crystal La4Cu3MoO12. Precession electron diffraction intensities are found to exhibit approximate two-beam behavior and demonstrate clear advantages over conventional SADP intensities for use in structure solution.


Assuntos
Microscopia Eletrônica/métodos , Óxidos/química , Difração de Raios X , Cobre/análise , Cristalização , Processamento de Imagem Assistida por Computador , Lantânio/análise , Microscopia Eletrônica/instrumentação , Molibdênio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...