1.
Appl Radiat Isot ; 80: 23-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23811634

RESUMO

A low cost Si-PIN photodiode-based radon monitor was successfully designed and produced to monitor precursory earthquake indicators in the Northern Anatolian Fault Line. The spatial distribution of (214)Po ions was determined by comparing the 7.69 MeV (214)Po peak in the MCA spectrum and the Geant4 energy distribution of alpha particles at various detector source distances.

2.
Appl Radiat Isot ; 78: 1-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23583920

RESUMO

Monitoring the (222)Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center.


Assuntos
Telefone Celular/instrumentação , Fotometria/instrumentação , Monitoramento de Radiação/instrumentação , Radônio/análise , Tecnologia de Sensoriamento Remoto/instrumentação , Telefone Celular/economia , Desenho de Equipamento , Análise de Falha de Equipamento , Fotometria/economia , Doses de Radiação , Monitoramento de Radiação/economia , Tecnologia de Sensoriamento Remoto/economia , Semicondutores/economia , Turquia
3.
J Radiol Prot ; 29(4): 527-34, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19923646

RESUMO

Radon concentrations in the working sections of the Zonguldak coal mines were determined and activity concentration measurements of natural (226)Ra, (232)Th and (40)K radionuclides were performed with high resolution passive gamma-ray spectrometry for coal samples collected from these sections. The (222)Rn concentration was found to be between 15 and 78 Bq m(-3), well below the action limit of 1000 Bq m(-3) according to ICRP65. The annual effective dose to miners due to inhalation of radon was determined to be between 60 and 312 microSv. Activity concentrations of (226)Ra, (232)Th and (40)K in the coal samples were found to be 13-164, 13-215 and 344-1100 Bq kg(-1), respectively. Radium equivalent activity, dose rate in air and average annual effective dose equivalents were calculated in the range of 66-602 Bq kg(-1), 32-265 nGy h(-1) and 30-244 microSv, respectively. The resultant total annual effective doses can be used to minimise the radiological risk to the coal miners.


Assuntos
Minas de Carvão/estatística & dados numéricos , Exposição Ocupacional/análise , Modelos de Riscos Proporcionais , Poluentes do Solo/análise , Carga Corporal (Radioterapia) , Raios gama , Humanos , Medição de Risco/métodos , Fatores de Risco , Turquia/epidemiologia
4.
Phys Rev Lett ; 100(9): 091602, 2008 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-18352695

RESUMO

The spin precession frequency of muons stored in the (g-2) storage ring has been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT violation signatures were searched for a nonzero delta omega a(=omega a mu+ - omega a mu-) and a sidereal variation of omega a mu+/-). No significant effect is found, and the following limits on the standard-model extension parameters are obtained: bZ = -(1.0+/-1.1) x 10(-23) GeV; (m mu dZ0 + HXY)=(1.8+/-6.0) x 10(-23) GeV; and the 95% confidence level limits b perpendicular mu+ <1.4 x 10(-24) GeV and b perpendicular mu- <2.6 x 10(-24) GeV.

5.
Phys Rev Lett ; 99(3): 032001, 2007 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-17678280

RESUMO

The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau(micro)=2.197 013(24) micros, is in excellent agreement with the previous world average. The new world average tau(micro)=2.197 019(21) micros determines the Fermi constant G(F)=1.166 371(6)x10(-5) GeV-2 (5 ppm). Additionally, the precision measurement of the positive-muon lifetime is needed to determine the nucleon pseudoscalar coupling g(P).

6.
Phys Rev Lett ; 99(3): 032002, 2007 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-17678281

RESUMO

The rate of nuclear muon capture by the proton has been measured using a new technique based on a time projection chamber operating in ultraclean, deuterium-depleted hydrogen gas, which is key to avoiding uncertainties from muonic molecule formation. The capture rate from the hyperfine singlet ground state of the microp atom was obtained from the difference between the micro(-) disappearance rate in hydrogen and the world average for the micro(+) decay rate, yielding Lambda(S)=725.0+/-17.4 s(-1), from which the induced pseudoscalar coupling of the nucleon, g(P)(q(2)=-0.88m(2)(micro))=7.3+/-1.1, is extracted.

7.
Phys Rev Lett ; 92(16): 161802, 2004 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-15169217

RESUMO

The anomalous magnetic moment of the negative muon has been measured to a precision of 0.7 ppm (ppm) at the Brookhaven Alternating Gradient Synchrotron. This result is based on data collected in 2001, and is over an order of magnitude more precise than the previous measurement for the negative muon. The result a(mu(-))=11 659 214(8)(3) x 10(-10) (0.7 ppm), where the first uncertainty is statistical and the second is systematic, is consistent with previous measurements of the anomaly for the positive and the negative muon. The average of the measurements of the muon anomaly is a(mu)(exp)=11 659 208(6) x 10(-10) (0.5 ppm).

8.
Phys Rev Lett ; 89(10): 101804, 2002 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-12225185

RESUMO

A higher precision measurement of the anomalous g value, a(mu)=(g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron, based on data collected in the year 2000. The result a(mu(+))=11 659 204(7)(5)x10(-10) (0.7 ppm) is in good agreement with previous measurements and has an error about one-half that of the combined previous data. The present world average experimental value is a(mu)(expt)=11 659 203(8)x10(-10) (0.7 ppm).

9.
Appl Radiat Isot ; 55(1): 9-12, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11339537

RESUMO

Thickness determination of Ta2O5 thin films, deposited on the glass substrates and metallic indium and gold thin films on both glass and aluminum substrates, were performed by neutron activation analysis. Thickness determination of these thin films were made by comparing gamma-rays emitted from the radio-isotopes in the thin film with the substrate material followed by the neutron irradiations. The method led to determination of the film thicknesses without using any standard sample. A complementary optical transmission measurement was also applied on multi-layered Ta2O5 thin films for determining the individual layer densities.

10.
Phys Rev Lett ; 86(11): 2227-31, 2001 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-11289896

RESUMO

A precise measurement of the anomalous g value, a(mu) = (g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron. The result a(mu+) = 11 659 202(14) (6) x 10(-10) (1.3 ppm) is in good agreement with previous measurements and has an error one third that of the combined previous data. The current theoretical value from the standard model is a(mu)(SM) = 11 659 159.6(6.7) x 10(-10) (0.57 ppm) and a(mu)(exp) - a(mu)(SM) = 43(16) x 10(-10) in which a(mu)(exp) is the world average experimental value.