Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Bone ; 120: 25-37, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30240961

RESUMO

Clinical retrospective studies have only reported limited improvements in hip fracture classification accuracy using finite element (FE) models compared to conventional areal bone mineral density (aBMD) measurements. A possible explanation is that state-of-the-art quasi-static models do not estimate patient-specific loads. A novel FE modeling technique was developed to improve the biofidelity of simulated impact loading from sideways falling. This included surrogate models of the pelvis, lower extremities, and soft tissue that were morphed based on subject anthropometrics. Hip fracture prediction models based on aBMD and FE measurements were compared in a retrospective study of 254 elderly female subjects from the AGES-Reykjavik study. Subject fragility ratio (FR) was defined as the ratio between the ultimate forces of paired biofidelic models, one with linear elastic and the other with non-linear stress-strain relationships in the proximal femur. The expected end-point value (EEV) was defined as the FR weighted by the probability of one sideways fall over five years, based on self-reported fall frequency at baseline. The change in maximum volumetric strain (ΔMVS) on the surface of the femoral neck was calculated between time of ultimate femur force and 90% post-ultimate force in order to assess the extent of tensile tissue damage present in non-linear models. After age-adjusted logistic regression, the area under the receiver-operator curve (AUC) was highest for ΔMVS (0.72), followed by FR (0.71), aBMD (0.70), and EEV (0.67), however the differences between FEA and aBMD based prediction models were not deemed statistically significant. When subjects with no history of falling were excluded from the analysis, thus artificially assuming that falls were known a priori with no uncertainty, a statistically significant difference in AUC was detected between ΔMVS (0.85), and aBMD (0.74). Multivariable linear regression suggested that the variance in maximum elastic femur force was best explained by femoral head radius, pelvis width, and soft tissue thickness (R2 = 0.79; RMSE = 0.46 kN; p < 0.005). Weighting the hip fracture prediction models based on self-reported fall frequency did not improve the models' sensitivity, however excluding non-fallers lead to significant differences between aBMD and FE based models. These findings suggest that an accurate assessment of fall probability is necessary for accurately identifying individuals predisposed to hip fracture.


Assuntos
Análise de Elementos Finitos , Fraturas do Quadril/classificação , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Estudos de Coortes , Feminino , Fêmur/patologia , Humanos , Islândia , Masculino , Probabilidade , Curva ROC , Estudos Retrospectivos
2.
Ann Biomed Eng ; 46(2): 270-283, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29181721

RESUMO

The limitations of areal bone mineral density measurements for identifying at-risk individuals have led to the development of alternative screening methods for hip fracture risk including the use of geometrical measurements from the proximal femur and subject specific finite element analysis (FEA) for predicting femoral strength, based on quantitative CT data (qCT). However, these methods need more development to gain widespread clinical applications. This study had three aims: To investigate whether proximal femur geometrical parameters correlate with obtained femur peak force during the impact testing; to examine whether or not failure of the proximal femur initiates in the cancellous (trabecular) bone; and finally, to examine whether or not surface fracture initiates in the places where holes perforate the cortex of the proximal femur. We found that cortical thickness around the trochanteric-fossa is significantly correlated to the peak force obtained from simulated sideways falling (R 2 = 0.69) more so than femoral neck cortical thickness (R 2 = 0.15). Dynamic macro level FE simulations predicted that fracture generally initiates in the cancellous bone compartments. Moreover, our micro level FEA results indicated that surface holes may be involved in primary failure events.


Assuntos
Osso Esponjoso , Cabeça do Fêmur , Fraturas do Quadril , Modelos Biológicos , Osso Esponjoso/patologia , Osso Esponjoso/fisiopatologia , Feminino , Cabeça do Fêmur/patologia , Cabeça do Fêmur/fisiopatologia , Análise de Elementos Finitos , Fraturas do Quadril/patologia , Fraturas do Quadril/fisiopatologia , Humanos , Masculino
3.
J Mech Behav Biomed Mater ; 78: 196-205, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29172124

RESUMO

Sideways falls are largely responsible for the highly prevalent osteoporotic hip fractures in today's society. These injuries are dynamic events, therefore dynamic FE models validated with dynamic ex vivo experiments provide a more realistic simulation than simple quasi-static analysis. Drop tower experiments using cadaveric specimens were used to identify the material mapping strategy that provided the most realistic mechanical response under impact loading. The present study tested the addition of compression-tension asymmetry, tensile bone damage, and cortical-specific strain rate dependency to the material mapping strategy of fifteen dynamic FE models of the proximal femur, and found improved correlations and reduced error for whole bone stiffness (R2 = 0.54, RSME = 0.87kN/mm) and absolute maximum force (R2 = 0.56, RSME =0.57kN), and a high correlation in impulse response (R2 = 0.82, RSME =12.38kg/s). Simulations using fully bonded nodes between the rigid bottom plate and PMMA cap supporting the femoral head had higher correlations and less error than simulations using a frictionless sliding at this contact surface. Strain rates over 100/s were observed in certain elements in the femoral neck and trochanter, indicating that additional research is required to better quantify the strain rate dependencies of both trabecular and cortical bone at these strain rates. These results represent the current benchmark in dynamic FE modeling of the proximal femur in sideways falls. Future work should also investigate improvements in experimental validation techniques by developing better displacement measurements and by enhancing the biofidelity of the impact loading wherever possible.


Assuntos
Acidentes por Quedas , Fêmur , Teste de Materiais , Fenômenos Mecânicos , Idoso , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Masculino
4.
Med Eng Phys ; 38(11): 1339-1347, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27641660

RESUMO

Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QCT. The inclusion of anisotropy measured from high resolution peripheral QCT (HR-pQCT) could potentially improve QCT-based FEA of the femur, although no improvements have yet been demonstrated in previous experimental studies. This study analyzed the effects of adding anisotropy to clinical resolution femur models by constructing six sets of FE models (two isotropic and four anisotropic) for each specimen from a set of sixteen femurs that were experimentally tested in sideways fall loading with a strain gauge on the superior femoral neck. Two different modulus-density relationships were tested, both with and without anisotropy derived from mean intercept length analysis of HR-pQCT scans. Comparing iso- and anisotropic models to the experimental data resulted in nearly identical correlation and highly similar linear regressions for both whole bone stiffness and strain gauge measurements. Anisotropic models contained consistently greater principal compressive strains, approximately 14% in magnitude, in certain internal elements located in the femoral neck, greater trochanter, and femoral head. In summary, anisotropy had minimal impact on macroscopic measurements, but did alter internal strain behavior. This suggests that organ level QCT-based FE models measuring femoral stiffness have little to gain from the addition of anisotropy, but studies considering failure of internal structures should consider including anisotropy to their models.


Assuntos
Fêmur , Análise de Elementos Finitos , Idoso , Idoso de 80 Anos ou mais , Anisotropia , Módulo de Elasticidade , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Estresse Mecânico , Tomografia Computadorizada por Raios X
5.
Med Eng Phys ; 38(7): 679-689, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27185044

RESUMO

Contributing to slow advance of finite element (FE) simulations for hip fracture risk prediction, into clinical practice, could be a lack of consensus in the biomechanics community on how to map properties to the models. Thus, the aim of the present study was first, to systematically quantify the influence of the modulus-density relationship (E-ρ) and the material mapping method (MMM) on the predicted mechanical response of the proximal femur in a side-ways fall (SWF) loading configuration and second, to perform a model-to-model comparison of the predicted mechanical response within the femoral neck for all the specimens tested in the present study, using three different modelling techniques that have yielded good validation outcome in terms of surface strain prediction and whole bone response according to the literature. We found the outcome to be highly dependent on both the E-ρ relationship and the MMM. In addition, we found that the three modelling techniques that have resulted in good validation outcome in the literature yielded different principal strain prediction both on the surface as well as internally in the femoral neck region of the specimens modelled in the present study. We conclude that there exists a need to carry out a more comprehensive validation study for the SWF loading mode to identify which combination of MMMs and E-ρ relationship leads to the best match for whole bone and local mechanical response. The MMMs tested in the present study have been made publicly available at https://simtk.org/home/mitk-gem.


Assuntos
Acidentes por Quedas , Fêmur/fisiologia , Análise de Elementos Finitos , Densidade Óssea , Humanos , Estresse Mecânico , Suporte de Carga
7.
Laeknabladid ; 83(10): 640-7, 1997 Oct.
Artigo em Islandês | MEDLINE | ID: mdl-19679910

RESUMO

Those elderly living in institutions have multiple social, health and mental problems, in addition to loss of function. The Resident Assessment Instrument assesses the individual in detail and his caring needs. Resident Assessment Protocols come with the instrument and a handbook that describes how to evaluate specific problems further. Quality indicators allow comparisons between institutions and thus the quality of care can be assessed in comparable groups of residents. The elderly can be put into defined resource utilisation groups and an average cost calculated per unit or nursing home. A pilot study was conducted in Iceland in 1994 to examine the utility of the instrument. It was shown that most of the residents were viewed as competent according to documents, even if about half of them had considerable cognitive dysfunction. Dementia was the most common diagnosis. One fourth of the residents took antidepressant medications and 54-62% took sedatives or hypnotic drugs. Eight out of 10 had dentures and one third had difficulty chewing. Many more interesting findings showed up that are described in a special report.

8.
J Theor Biol ; 113(2): 231-59, 1985 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-3999777

RESUMO

Kinetics of linear sequences of enzymatic reactions converting a single substrate into a single product are examined with emphasis on obtaining the relationship between the individual kinetic parameters and overall dynamic behavior. Chains of reactions exhibiting irreversible Michaelis-Menten kinetics are examined via scaling, linearization and modal analysis. The modal analysis gives the conditions under which the quasi-steady state assumption is applicable for one reaction relative to another in such a reaction sequence. The linearized description permits characterization of the transient response in terms of temporal moments. The moments provide useful physical insight and also provide a basis for systematic model reduction.


Assuntos
Metabolismo , Modelos Biológicos , Enzimas/metabolismo , Análise de Fourier , Cinética , Matemática
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...