Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Control Release ; 365: 348-357, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37972762

RESUMO

Three-dimensional (3D) printing is revolutionising the way that medicines are manufactured today, paving the way towards more personalised medicine. However, there is limited in vivo data on 3D printed dosage forms, and no studies to date have been performed investigating the intestinal behaviour of these drug products in humans, hindering the complete translation of 3D printed medications into clinical practice. Furthermore, it is unknown whether conventional in vitro release tests can accurately predict the in vivo performance of 3D printed formulations in humans. In this study, selective laser sintering (SLS) 3D printing technology has been used to produce two placebo torus-shaped tablets (printlets) using different laser scanning speeds. The printlets were administered to 6 human volunteers, and in vivo disintegration times were assessed using magnetic resonance imaging (MRI). In vitro disintegration tests were performed using a standard USP disintegration apparatus, as well as an alternative method based on the use of reduced media volume and minimal agitation. Printlets fabricated at a laser scanning speed of 90 mm/s exhibited an average in vitro disintegration time of 7.2 ± 1 min (measured using the USP apparatus) and 25.5 ± 4.1 min (measured using the alternative method). In contrast, printlets manufactured at a higher laser scanning speed of 130 mm/s had an in vitro disintegration time of 2.8 ± 0.8 min (USP apparatus) and 18.8 ± 1.9 min (alternative method). When tested in humans, printlets fabricated at a laser scanning speed of 90 mm/s showed an average disintegration time of 17.3 ± 7.2 min, while those manufactured at a laser scanning speed of 130 mm/s exhibited a shorter disintegration time of 12.7 ± 6.8 min. Although the disintegration times obtained using the alternative method more closely resembled those obtained in vivo, no clear correlation was observed between the in vitro and in vivo disintegration times, highlighting the need to develop better in vitro methodology for 3D printed drug products.


Assuntos
Lasers , Impressão Tridimensional , Humanos , Comprimidos , Composição de Medicamentos , Imageamento por Ressonância Magnética , Tecnologia Farmacêutica/métodos , Liberação Controlada de Fármacos
2.
Br J Radiol ; 95(1130): 20210511, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34757835

RESUMO

OBJECTIVE: The aim of this study is to investigate whether the primary tumour response to neoadjuvant chemotherapy (NAC), based on the increase in the ADC-values (apparent diffusion coefficient) within the breast lesion, could help to predict axillary complete response. METHODS: We retrospectively included 74 patients who were treated with NAC followed by surgery at Lucus Augusti Hospital between January 2015 and September 2020. Simple logistic regression was used to evaluate the factors associated with axillary pathological complete response, including the changes in breast tumour ADC-values due to the treatment. RESULTS: Axillary complete response was correlated with negative oestrogen receptor status, Her2 positivity and response of primary tumour. It was achieved in 31% of the patients. In addition, the increase in the tumour ADC-values with NAC was higher for responders. Among the tumours that demonstrated an increase in ADC-value >0.92 ×10-3 mm2/s, 42.8% (15/35) showed axillary complete response. Eight (20.5%) breast cancers with an increase in ADC below the cut-off value were found to have no metastatic nodes after treatment (p = 0.038). CONCLUSION: Our results suggest that the performance of models predicting axillary response to NAC can be improved by adding the tumour response determined also using diffusion-weighted imaging. ADVANCES IN KNOWLEDGE: For the fist time, we investigate the relation between tumour response to NAC, assessed using diffusion-weighted imaging, and axillary pathologic complete response.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Imagem de Difusão por Ressonância Magnética/métodos , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/tratamento farmacológico , Terapia Neoadjuvante/métodos , Adulto , Idoso , Axila , Neoplasias da Mama/química , Neoplasias da Mama/patologia , Quimioterapia Adjuvante/métodos , Feminino , Humanos , Modelos Logísticos , Metástase Linfática/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
3.
J Radiol Case Rep ; 9(10): 18-25, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26629290

RESUMO

Wandering spleen is a rare condition, characterized by a mobile spleen that is attached only by an elongated vascular pedicle, allowing it to migrate to any part of the abdomen or pelvis. Mesenteroaxial gastric volvulus usually occurs in children and may be associated with wandering spleen. Both entities result from abnormal laxity or absence of the peritoneal attachments due to abnormal fusion of the peritoneal mesenteries. Pancreatic volvulus is a very rare anomaly, with only a few isolated case reports described in association with wandering spleen. Anomalous right sided descending and sigmoid colon is a very rare entity and its association with wandering spleen has not been previously reported. We report a case of wandering spleen associated with mesenteroaxial gastric volvulus, pancreatic volvulus and rightward shift of the splenic flexure of the colon and right sided descending and sigmoid colon in a young female.


Assuntos
Colo Descendente/anormalidades , Colo Sigmoide/anormalidades , Volvo Intestinal/complicações , Pâncreas/anormalidades , Volvo Gástrico/complicações , Anormalidade Torcional/complicações , Baço Flutuante/complicações , Colo Descendente/diagnóstico por imagem , Colo Sigmoide/diagnóstico por imagem , Feminino , Humanos , Volvo Intestinal/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Prognóstico , Radiografia , Volvo Gástrico/diagnóstico por imagem , Volvo Gástrico/etiologia , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/etiologia , Baço Flutuante/diagnóstico por imagem , Baço Flutuante/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...