Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Chromatogr A ; 1713: 464498, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37980809

RESUMO

When therapeutic proteins are analysed under hydrophilic interaction liquid chromatography (HILIC) conditions, there is an inherent mismatch between the sample diluent (proteins must be solubilised in aqueous media) and the mobile phase, which is mostly composed of aprotic solvent (acetonitrile). This difference in eluent strength between sample diluent and mobile phase is responsible for severe analyte breakthrough and peak distortion. As demonstrated with therapeutic proteins of different sizes (insulin of 6 kDa, anakinra of 17 kDa and rituximab subunits of 25 and 50 kDa), only very small volumes of 0.1-0.2 µL can be injected without breakthrough effects, when performing rapid analysis on short HILIC columns of 20-50 mm, leading to poor sensitivity. In order to avoid the undesired effect of the strong sample diluent, a special injection program should be preferred. This consists in the addition and automatic injection of a defined volume of weak solvent (acetonitrile) along with the sample to increase retention factors during sample loading. Various injection programs were tested, including the addition of a pre-injection or post-injection or both (bracketed injection) of acetonitrile plugs. Several weak to strong injection solvent ratios of 1:1, 1:2, 1:4 and 1:10 were tested. Our work proves that the addition of a pre-plug solvent with a weak vs. strong injection solvent ratio of 1:10 is a valuable strategy to inject relatively large volumes of proteins in HILIC, regardless of column dimensions, thus maximising sensitivity. No peak deformation or breakthrough was observed under these conditions. However, it is important to note that peak broadening (40 % larger peaks) was observed when the injection program increased the injection solvent ratio from 1:1 to 1:10. Finally, this strategy was applied to a wide range of therapeutic mAb products with different physico-chemical properties. In all cases, relatively large volumes can be successfully injected onto small volume HILIC columns using a purely aqueous sample diluent, as long as an appropriate (weak) solvent pre-injection is applied.


Assuntos
Água , Cromatografia Líquida , Solventes/química , Água/química , Interações Hidrofóbicas e Hidrofílicas , Acetonitrilas/química , Indicadores e Reagentes
2.
Vaccines (Basel) ; 11(11)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-38005967

RESUMO

Comirnaty™ and Spikevax™ were the first vaccines approved for human use based on modified non-replicating mRNA lipophilic nanoparticle (mRNA-LNP) technology, with great success in the treatment of COVID-19. They have been used massively worldwide. One of the major inconveniences of these vaccines is related to pharmaceutical stability issues. Proper transportation, storage, and in-use handling before administration to patients are critical steps since failures can potentially reduce potency. In this research, the in-use stability of Comirnaty™ and Spikevax™ clinical samples was analysed and the results were compared. As changes in the size of the mRNA-LNPs are related to potency, these modifications were analysed by qualitative Dynamic Light Scattering (DLS) as a stability-indicating method for control and stressed vaccine samples. Strong stress factors (accelerated light irradiation, manual shaking, and vortex vibration) and conditions that mimic in-use handling (exposure to natural light and room temperature, repeated cycles of injections, and 24 h storage in syringes) were checked. The morphology of the mRNA-LNPs was analysed by Transmission Electron Microscopy (TEM) to better interpret and support the DLS results. Although the two vaccines are based on the same mRNA-LNP technology, the results demonstrate that they are characterised by very different particle size profiles and behaviours against different handling/stress conditions.

3.
J Chromatogr A ; 1709: 464359, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37717303

RESUMO

The impact of injected sample volume on apparent efficiency has been studied for very short columns in a systematic way. For large molecules such as therapeutic proteins, it was found that relatively large volumes can be injected onto ultra-short RPLC and IEX columns (i.e. L < 50 mm) without significantly affecting the quality of the separation. This favourable behavior is due to the on-off elution mechanism of large molecules and to the fact that therapeutic protein samples are formulated in aqueous-based media, which is the weakest solvent in RPLC and IEX. Therefore, their peak is strongly focused at the column inlet even when large volume is injected, and pre-column peak dispersion is compensated. However, ultra-short HILIC columns do not seem to be favorable, as they require for very low injection volume to avoid detrimental peak splitting and breakthrough effects. Such peak distortion is related to the inherent solvent mismatch between sample diluent (aqueous) and mobile phase strength (highly organic in HILIC). When studying mass load, the ranking of the elution modes was the same, and the largest relative mass could be injected onto IEX columns (as large as 10% sample to sorbent mass), without affecting the separation quality.

4.
Eur J Pharm Biopharm ; 184: 103-115, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36669672

RESUMO

Teduglutide (Revestive®) is a glucagon-like peptide-2 analogue used for the treatment of short bowel syndrome, a rare life-threatening condition in which the amount of functional gut is too short to enable proper absorption of nutrients and fluids. During handling prior to administration to the patient in hospital, it is possible that peptide-based medicines may be exposed to environmental stress conditions that could affect their quality. It is therefore essential to carry out stress testing studies to evaluate how such medicines respond to these stresses. For this reason, in this paper we present a strategy for a comprehensive analytical characterization of a peptide and a stress testing study in which it was subjected to various stress conditions: heating at 40 °C and 60 °C, light exposure and shaking. Several complementary analytical techniques were used throughout this study: Far UV circular dichroism, intrinsic protein fluorescence spectroscopy, dynamic light scattering, size-exclusion chromatography and intact and peptide mapping reverse-phase chromatography coupled to mass spectrometry. To the best of our knowledge, this is the first study to offer an in-depth description of the chemical structure of teduglutide peptide and its physicochemical characteristics after stress stimuli were applied to the reconstituted medicine Revestive®.


Assuntos
Peptídeos , Síndrome do Intestino Curto , Humanos , Síndrome do Intestino Curto/tratamento farmacológico , Peptídeo 2 Semelhante ao Glucagon/uso terapêutico , Espectrometria de Massas , Fármacos Gastrointestinais
5.
Anal Methods ; 14(43): 4359-4369, 2022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36263764

RESUMO

Teduglutide (Revestive®, 10 mg mL-1) is a recombinant human glucagon-like peptide 2 analogue, used in the treatment of short bowel syndrome, a serious and highly disabling condition which results from either too small a length of intestine or loss of critical intestinal function. The determination of therapeutic compounds of protein-nature is always challenging due to their complex structure. In this work, we present a fast, straightforward reversed phase (RP)UHPLC-UV-(HESI/ORBITRAP)MS method for the identification and quantification of the intact teduglutide peptide. The method has been developed and validated in accordance with the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines; therefore, linearity, limits of detection and quantification, accuracy (precision and trueness), robustness, system suitability and specificity using the signal from the UV and MS, have been evaluated. The validation performance parameters obtained from the UV and MS signals were compared throughout the work, to select the most suitable. To study the specificity of the method and the impact of medicine mishandling under hospital conditions, force degradation studies were performed, i.e. thermal (40 °C and 60 °C), shaking (mechanical) and light (accelerated exposition) effects. Identification by the exact mass of teduglutide was achieved and it was confirmed that the peptide does not undergo any post-translational modifications (PTMs). To the best of our knowledge, the present work reports the first method developed for the simultaneous identification, structural characterization, and quantification of the therapeutic teduglutide peptide. Finally, the proposed method is able to indicate stability when quantifying the intact teduglutide since detects and characterises the exact mass of the degradation/modification products.


Assuntos
Síndrome do Intestino Curto , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Síndrome do Intestino Curto/tratamento farmacológico , Peptídeo 2 Semelhante ao Glucagon/uso terapêutico , Peptídeos/uso terapêutico
6.
J Pharm Biomed Anal ; 221: 115064, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36152491

RESUMO

Teduglutide, the active ingredient of the medicine Revestive® (5 mg), is a recombinant therapeutic peptide that mimics the effects of the endogenous glucagon-like peptide 2 (GLP-2). It stimulates intestinal growth, adaptation and function in patients with Short Bowel Syndrome who are dependent on parenteral nutrition. The Summary of Product Characteristics recommends immediate use of the reconstituted solutions and the discarding of any subsequent surplus. This study aims to carry out a long-term stability study that reproduces hospital conditions of use which provide sound evidence regarding the use of teduglutide surplus beyond the Summary Product Characteristics recommendations. We conducted a stability study of teduglutide solutions prepared from a 5 mg vial of Revestive®. Some of the solutions were stored in their original vial after reconstitution, while others were repackaged in plastic syringes to evaluate their physicochemical stability over time. For this purpose, we applied a set of previously validated analytical methodologies to evaluate the main critical quality attributes of teduglutide, i.e., primary (including post-tralational modifications), secondary and tertiary structures, aggregates, particulate, concentration and pH. The results indicate that the solutions maintain high physicochemical stability over time, regardless of the storage temperature (4ºC or -20ºC) or the storage container (vials or syringes). This research provides new data on the stability of Revestive® that will be of great value to hospital pharmacists. This comprehensive assessment of the physicochemical long-term stability of TGT has demonstrated that under the storage conditions and over the period studied here, the medicine maintains its quality, efficacy and safety profiles.


Assuntos
Peptídeo 2 Semelhante ao Glucagon , Síndrome do Intestino Curto , Fármacos Gastrointestinais , Peptídeo 2 Semelhante ao Glucagon/uso terapêutico , Humanos , Peptídeos/farmacologia , Plásticos , Síndrome do Intestino Curto/tratamento farmacológico
7.
Artigo em Inglês | MEDLINE | ID: mdl-35605365

RESUMO

Therapeutic monoclonal antibodies (mAbs) represent a very important class of the current biopharmaceutics. The great complexity of their structure made necessary the use of different analytical approaches for assessing different physico-chemical properties. In this work, weak cation exchange (WCX) high performance liquid chromatography with diode array detection ((WCX)HPLC/DAD) is used to assess the charge variant profile. The method here developed combined the effect of ionic strength and controlled pH gradient and allows for the charge variants analysis of the five mAbs studied, namely bevacizumab (BVZ), cetuximab (CTX) infliximab (INF), rituximab (RTX) and trastuzumab (TTZ), which are among the most used mAbs worldwide. The differences in the charge variants in the natural isoforms of the mAbs promoted characteristic WCX chromatograms for each of mAbs that can be also useful for identification purposes. These chromatograms have provided to be suitable for tracking changes in the charge variants of each mAb analyzed both in controlled degraded and in stabilities study along time of in-use samples solutions at 2 mg/mL in 0.9% NaCl stored refrigerated (at 4 °C) and frozen (-20 °C) for two months. The results obtained indicated different stabilities of these mAbs, all IgG1, against degradation by different stressed environmental conditions and in-use stability along two months.


Assuntos
Anticorpos Monoclonais , Anticorpos Monoclonais/química , Cátions , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia por Troca Iônica/métodos , Infliximab/química , Trastuzumab
8.
J Pharm Biomed Anal ; 203: 114209, 2021 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-34153938

RESUMO

A range of biopharmaceutical products are used to target Vascular Endothelial Growth Factor (VEGF), including Eylea® (aflibercept, AFL) and Zaltrap® (ziv-aflibercept, ziv-AFL). The first is indicated for ophthalmological diseases such as neovascular (wet) age-related macular degeneration, while the second is used in the treatment of metastatic colorectal cancer. The stability of AFL in prefilled syringes has been widely studied; however, no research has yet been done on the stability of ziv-AFL in polyolefin infusion bags. Therefore, the purpose of the present research is to evaluate the stability of ziv-AFL (Zaltrap®) clinical solutions prepared under aseptic conditions in polyolefin infusion bags at two different concentrations, i.e. 4.0 and 0.6 mg/mL, and stored refrigerated in darkness at 2-8 °C for 14 days. With that aim, the ziv-AFL clinical solutions were assessed by analysing changes in its physicochemical and functional properties. The distribution of the particulates was studied over a range of 0.001-10 µm by Dynamic Light Scattering (DLS); oligomers were analysed by Size-Exclusion High-Performance Chromatography with Diode Array Detection (SE/HLPC-DAD); the secondary structure of the protein was studied by far UV Circular Dichroism (CD) and the tertiary structure by Intrinsic Tryptophan Fluorescence (IT-F) and Intrinsic Protein Fluorescence (IP-F); charge variants were assessed by Strong Cation Exchange Ultra-High-Performance Chromatography with UV detection (SCX/UHPLC-UV); functionality was evaluated by ELISA by measuring the biological activity as manifested in the extension of the immunological reaction of the ziv-AFL with its antigen (VEGF). Neither aggregation nor oligomerization were detected by the techniques mentioned above. Secondary and tertiary structures remained unchanged over the 14-day period, as did charge variants. The functionality observed initially was maintained along time. Therefore, it could be proposed that the ziv-AFL clinical solutions studied showed great physicochemical and functional stability over a period of two weeks, regardless of the concentration, i.e. 4 or 0.6 mg/mL.


Assuntos
Receptores de Fatores de Crescimento do Endotélio Vascular , Fator A de Crescimento do Endotélio Vascular , Infusões Parenterais , Proteínas Recombinantes de Fusão
9.
J Pharm Anal ; 10(6): 532-545, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32837741

RESUMO

COVID-19, a disease caused by the novel coronavirus SARS-CoV-2, has produced a serious emergency for global public health, placing enormous stress on national health systems in many countries. Several studies suggest that cytokine storms (interleukins) may play an important role in severe cases of COVID-19. Neutralizing key inflammatory factors in cytokine release syndrome (CRS) could therefore be of great value in reducing the mortality rate. Tocilizumab (TCZ) in its intravenous (IV) form of administration -RoActemra® 20 mg/mL (Roche)-is indicated for treatment of severe CRS patients. Preliminary investigations have concluded that inhibition of IL-6 with TCZ appears to be efficacious and safe, with several ongoing clinical trials. This has led to a huge increase in demand for IV TCZ for treating severe COVID-19 patients in hospitals, which has resulted in drug shortages. Here, we present a comparability study assessing the main critical physicochemical attributes of TCZ solutions used for infusion, at 6 mg/mL and 4 mg/mL, prepared from RoActemra® 20 mg/mL (IV form) and from RoActemra® 162 mg (0.9 mL solution pre-filled syringe, subcutaneous(SC) form), to evaluate the use of the latter for preparing clinical solutions required for IV administration, so that in a situation of shortage of the IV medicine, the SC form could be used to prepare the solutions for IV delivery of TCZ. It is important to remember that during the current pandemic all the medicines are used off-label, since none of them has yet been approved for the treatment of COVID-19.

10.
J Pharm Anal ; 10(1): 23-34, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32123597

RESUMO

With the size of the biopharmaceutical market exponentially increasing, there is an aligned growth in the importance of data-rich analyses, not only to assess drug product safety but also to assist drug development driven by the deeper understanding of structure/function relationships. In monoclonal antibodies, many functions are regulated by N-glycans present in the constant region of the heavy chains and their mechanisms of action are not completely known. The importance of their function focuses analytical research efforts on the development of robust, accurate and fast methods to support drug development and quality control. Released N-glycan analysis is considered as the gold standard for glycosylation characterisation; however, it is not the only method for quantitative analysis of glycoform heterogeneity. In this study, ten different analytical workflows for N-glycan analysis were compared using four monoclonal antibodies. While observing good comparability between the quantitative results generated, it was possible to appreciate the advantages and disadvantages of each technique and to summarise all the observations to guide the choice of the most appropriate analytical workflow according to application and the desired depth of data generated.

11.
J Pharm Biomed Anal ; 185: 113233, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32169790

RESUMO

Ziv-aflibercept (ziv-AFL) is a complex fusion protein which is widely used in hospitals for the treatment of colorectal metastatic cancer. Charge variants are critical attributes for assessing post-transitional modifications (PMTs) that have to be controlled during the development and manufacture of these proteins and until their administration to patients. Cation exchange (CEX) chromatography is a charge-sensitive analytical method that is well suited for analysing charge variants in proteins. The aim of this paper is to analyse the charge variants of ziv-AFL in the medicine (Zaltrap®) when fresh and when degraded. Two CEX chromatographic methods were compared for this purpose. The former was an adaptation of the method used in the first published study in which charge variants were analysed via pH gradient elution using volatile, low ionic strength buffers with direct coupling to high-resolution Orbitrap mass spectrometry. The second method was developed and optimized during our research using the salt-mediated pH gradient mode and classical non-volatile, high ionic strength buffers which were incompatible with direct coupling with mass detection. Fresh and controlled degraded samples of ziv-AFL were used to evaluate the capacity of both CEX chromatographic strategies for detecting charge variants in ziv-AFL. In the controlled degradation study the samples of the medicine were subjected to three stress factors: temperature of 60 °C for three hours, freeze/thaw process -two cycles-, and exposure to light for twelve hours. The CEX chromatographic method with non-volatile salts in the mobile phase enabled better detection of charge variants degraded ziv-AFL samples than the method using volatile salts with lower ionic strength. In addition, the complexity of the mass spectra data generated made it impossible to identify the multicharge variant species of ziv-AFL. Although charge variants were not separated in ziv-AFL fresh sample, our results indicate that the method with non-volatile salts in the mobile phase could be used to characterize and track changes in the charge variant UV chromatographic profile of ziv-AFL in fresh and degraded samples, even though it cannot be coupled to a mass detector and there is therefore no information about mass. The increase of basic protein degraded compounds were the most important degradation pattern detected in ziv-AFL (Zaltrap®).


Assuntos
Química Farmacêutica/métodos , Receptores de Fatores de Crescimento do Endotélio Vascular/análise , Proteínas Recombinantes de Fusão/análise , Cátions , Cromatografia por Troca Iônica/métodos , Estudos de Viabilidade , Humanos , Concentração de Íons de Hidrogênio , Espectrometria de Massas/métodos , Concentração Osmolar , Estudo de Prova de Conceito , Proteólise , Receptores de Fatores de Crescimento do Endotélio Vascular/química , Proteínas Recombinantes de Fusão/química
12.
Sci Rep ; 10(1): 2675, 2020 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-32060315

RESUMO

Aflibercept (AFL) is an Fc fusion protein used in the treatment of colorectal cancers and different ophthalmological diseases. There are two medicines in which AFL is the active substance: Zaltrap and Eylea, referred as ziv-AFL and AFL respectively. No proper accelerated degradation studies were published on either AFL or ziv-AFL. These studies are essential during research, development and manufacturing stages. Here, we characterized ziv-AFL and submitted it to different stress conditions: light, 60 °C, freeze-thaw cycles, changes in pH, high hypertonic solution and strong denaturing conditions. We used an array of techniques to detect aggregation (SE-HPLC/DAD and DLS), changes in secondary structure (Far-UV circular dichroism), changes in conformation or tertiary structure (Intrinsic tryptophan fluorescence) and alterations in functionality (ELISA). Results indicate that aggregation is common degradation pathway. Two different types of aggregates were detected: dimers and high molecular weight aggregates attributed to ß-amyloid-like structures. Secondary structure was maintained in most of the stress tests, while conformation was altered by almost all the tests except for the freeze-thaw cycles. Functionality, evaluated by its immunochemical reaction with VEGF, was found to be stable but with decrease when exposed to light and with likely partial inactivation of the drug when pH was altered.


Assuntos
Inibidores da Angiogênese/química , Estabilidade de Medicamentos , Receptores de Fatores de Crescimento do Endotélio Vascular/química , Proteínas Recombinantes de Fusão/química , Inibidores da Angiogênese/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Congelamento/efeitos adversos , Temperatura Alta/efeitos adversos , Humanos , Concentração de Íons de Hidrogênio , Soluções Hipertônicas/efeitos adversos , Injeções Intravítreas , Luz/efeitos adversos , Receptores de Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Proteínas Recombinantes de Fusão/uso terapêutico , Fator A de Crescimento do Endotélio Vascular/genética
13.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-823980

RESUMO

With the size of the biopharmaceutical market exponentially increasing, there is an aligned growth in the importance of data-rich analyses, not only to assess drug product safety but also to assist drug development driven by the deeper understanding of structure/function relationships. In monoclonal antibodies, many functions are regulated by N-glycans present in the constant region of the heavy chains and their mechanisms of action are not completely known. The importance of their function focuses analytical research efforts on the development of robust, accurate and fast methods to support drug development and quality control. Released N-glycan analysis is considered as the gold standard for glycosylation characterisation;however, it is not the only method for quantitative analysis of glycoform heterogeneity. In this study, ten different analytical workflows for N-glycan analysis were compared using four monoclonal antibodies. While observing good comparability between the quantitative results generated, it was possible to appreciate the advantages and disadvantages of each technique and to summarise all the observations to guide the choice of the most appropriate analytical workflow ac-cording to application and the desired depth of data generated.

14.
BioDrugs ; 33(2): 193-205, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30875076

RESUMO

BACKGROUND: There are two products in which infliximab is the active pharmaceutical ingredient. These are Remicade® (INF; reference product) and Remsima™/Inflectra™ (CT-P13; infliximab biosimilar). Remsima™/Inflectra™ are bioidentical products. Different recommendations have been made for the clinical solutions of each brand (Remicade® or Remsima™/Inflectra™) despite the manufacturer of the biosimilar claiming high levels of similarity to the innovator. OBJECTIVE: The objective of this study was to assess and compare stability against degradation and over time of different clinical infliximab solutions prepared from Remicade® and from Remsima™/Inflectra™ using a suitable set of characterization methods in line with the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) recommendations. METHODS: Reconstituted solutions of INF and CT-P13 and dilutions as used in hospital were stored in glass vials (10 and 2 mg/mL) or in polyolefin infusion bags (0.4 mg/mL) refrigerated between 2 and 8 °C for 2 weeks. Regarding the physicochemical properties, the distribution of the particulates were studied over a range of 0.001-1 µm by dynamic light scattering (DLS) and oligomers up to 8 monomer were analyzed by native size-exclusion ultra-high-performance liquid chromatography with ultraviolet (UV)-visible detection coupled to (native) mass spectrometry (SE/UHPLC-UV-(native) MS); mass spectrometry was also used to evaluate natural aggregates and isoform profile; DLS was also employed to detect gross conformational changes by tracking the hydrodynamic radius (HR). The secondary structure of the proteins was studied by far UV circular dichroism (CD). The tertiary structure was investigated by intrinsic tryptophan fluorescence (IT-F). Reverse-phase ultra-high-performance liquid chromatography with UV detection (RP/UHPLC-UV) was used to analyze intact INF and CT-P13 for quantification purposes. Functionality was evaluated via the biological activity measured by the extension of the immunological reaction of the INF and the CT-P13 with its antigen, i.e., the tumor necrosis factor-α by enzyme-linked immunosorbent assay (ELISA). RESULTS: The stress applied to INF and CT-P13 solutions showed similar levels of aggregate formation, structural variation, and chemical modifications. The only noteworthy difference between INF and CT-P13 was detected in their behavior to freeze-thaw cycles, in which CT-P13 showed slightly more robustness. INF and CT-P13 showed identical CD spectra, similar to those reported for IgG1 in which there is dominance in ß sheet secondary structures; this typical conformation remained unmodified over time in INF and CT-P13. No significant changes were detected in the tertiary structure and no aggregates process was noticed over the time studied. Polydispersity slightly increased for the most concentrated solutions, while there were no meaningful differences in the HR in the solutions over time. The concentration of INF and CT-P13 also remained constant. Differences in the native isoform MS profile were detected, as expected by the different glycosylation pattern, with no important modification over time. Functionality was maintained over the test period (60 days) and was similar in all the solutions tested, with no differences between INF and biosimilar solutions. CONCLUSIONS: High levels of similarity were noticed in the behavior of INF and CT-P13 when subjected to stress. When stored refrigerated at between 2 and 8 °C and prepared as normally used in the hospital pharmacy, all solutions showed physicochemical and functional stability for all the concentrations tested and all containers, at least for the 14-day test period.


Assuntos
Anticorpos Monoclonais/química , Medicamentos Biossimilares/química , Infliximab/química , Técnicas de Química Analítica , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Humanos , Temperatura
15.
J Pharm Biomed Anal ; 159: 437-448, 2018 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-30071467

RESUMO

Monoclonal antibodies (mAbs) are one of the most important types of biopharmaceutics and have proved enormously successful in the treatment of cancers and autoimmune diseases. In this paper, we present a fast, straightforward reversed phase (RP)UHPLC-UV-(HESI/Orbitrap) MS method for the separation and identification of five of the most commonly used mAbs, i.e. bevazizumab (BEV), cetuximab (CTX), infliximab (INF), rituximab (RTX) and trastuzumab (TTZ) in mixtures. The RP mAbs separation was performed in a divinylbenzene-based monolithic column, after statistical design of the experiments with a novel approach for optimizing chromatographic conditions called the heteroscedasticity function. Results led us to split the initial mixture of five mAbs into two mixtures with four mAbs each, one containing RTX and the other TTZ. The method was validated for quantification using the signal from the UV detector and identification by (HESI-Orbitrap)MS. Direct MS characterization of the intact isoform profile of each mAb was also obtained. Advantages and disadvantages of the use of trifluoroacetic acid or formic acid as ion pairing agents for mass spectrometric analysis and chromatographic separation are discussed. Validation was performed using an internal protocol based on well-known international guidelines such as the International Conference on Harmonization (ICH) guideline, the US Food and Drugs Administration (FDA) guideline and the United Stated Pharmacopeia (USP) guideline. Performance parameters such as linearity, accuracy (precision and trueness), detection limits, quantification limits and robustness were evaluated. Robustness was established by studying the total and one-sided effects of four selected variables: column temperature, trifluoroacetic acid content in the mobile phases, initial proportion of eluent B and gradient. The results indicated the suitability of this method for quantifying these five mAbs in mixtures, as well as its robustness, reproducibility and sensitivity.


Assuntos
Anticorpos Monoclonais/análise , Cromatografia Líquida de Alta Pressão/métodos , Combinação de Medicamentos , Espectrometria de Massas/métodos , Guias como Assunto , Limite de Detecção , Isoformas de Proteínas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...