Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Int Endod J ; 56(8): 955-967, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37165944

RESUMO

AIM: This study aimed to evaluate the cytotoxicity, biocompatibility and osteoinductive profile of a mineral trioxide aggregate (MTA)-hydrogel-based material (MTA Flow) in comparison with MTA Angelus. METHODOLOGY: Cell viability was evaluated in human periodontal ligament stem cells (hPDLSCs) using the methyl-thiazol-tetrazolium (MTT) colourimetric assay. Polyethylene tubes containing the tested materials and empty polyethylene tubes (control) were implanted in the subcutaneous tissue of Wistar rats. Cellular (lymphocyte infiltration) and extracellular events (ECM; collagen fibres) were analysed in histological sections. Immunohistochemical (collagen I, osteopontin, bone sialoprotein, bone morphogenetic protein4) analyses were also performed. RESULTS: At 24, 48 and 72 h, all tested groups showed cell viability similar to control (p > .05). Regarding biocompatibility, all groups showed similar cellular events represented by a slight inflammatory reaction characterized by hyperaemia and a mild lymphocytic inflammatory infiltrate. The analysis of lymphocytes during the time showed a decrease in these cells in the control group and a significant interaction between MTA Angelus and control (p < .001), with MTA Angelus showing a more extensive inflammatory infiltrate. Regarding fibres, an increase in content was observed in all groups during the experimental time (7, 30 and 60 days), however, no difference was detected among the experimental groups (p = .063). After 60 days, the immunoexpression of bone matrix proteins in the MTA Flow group was similar to or higher than that observed in the MTA Angelus and in the control group. CONCLUSIONS: MTA Flow showed a non-cytotoxic behaviour, biocompatibility and ability to stimulate tissue mineralization.


Assuntos
Materiais Biocompatíveis , Materiais Restauradores do Canal Radicular , Ratos , Animais , Humanos , Ratos Wistar , Materiais Biocompatíveis/farmacologia , Compostos de Cálcio/farmacologia , Hidrogéis , Óxidos/farmacologia , Silicatos/toxicidade , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Colágeno , Polietilenos , Combinação de Medicamentos , Compostos de Alumínio/toxicidade , Materiais Restauradores do Canal Radicular/toxicidade , Teste de Materiais
2.
J Prosthet Dent ; 2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35282937

RESUMO

STATEMENT OF PROBLEM: Little is known about the extent to which hydrogen peroxide as used for tooth bleaching could be carcinogenic to the oral mucosa. PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate whether hydrogen peroxide as used for tooth bleaching has carcinogenic effects on the oral mucosa. MATERIAL AND METHODS: PubMed, Web of Science, Scopus, and Embase electronic databases were searched. Studies evaluating different outcomes potentially related to the carcinogenic effects of hydrogen peroxide for tooth bleaching on the oral mucosa were included. Risk of bias was assessed by the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE), Risk Of Bias in Non-randomized Studies of Interventions (ROBINS-I), or Risk of Bias 2 (RoB 2) tools. The strength of the evidence was assessed by using the Grading of Recommendation, Assessment, Development, and Evaluation (GRADE) protocol. The quantitative analysis was performed with means, standard deviations, and 95% confidence intervals (CIs). Heterogeneity was analyzed by using I-squared statistics. RESULTS: Thirteen articles comprising 5 animal and 8 clinical studies met the inclusion criteria. Three of the 5 animal studies associated the bleaching agents with a carcinogen and demonstrated an enhancement of the carcinogenic effect, but probably with the bleaching agent acting only as a promoter. Five clinical studies concluded that the bleaching agents did not cause mutagenic stress on the oral mucosa by using the micronucleus test. The meta-analysis demonstrated that the frequency of micronuclei did not differ significantly between baseline and 30 days after bleaching (mean difference: 0.48; 95% CI, -1.49, 2.46; P=.63). CONCLUSIONS: This systematic review indicated that hydrogen peroxide does not appear to have carcinogenic effects on the oral mucosa.

3.
J Conserv Dent ; 23(4): 364-369, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33623237

RESUMO

AIM: The aim was to compare cyclic fatigue, torsional failure, and flexural resistance of NiTi endodontic files: Hyflex CM (HYF), Genius files (GEN), WaveOne Gold (WOG), and ProTaper Universal (PTU). MATERIALS AND METHODS: Fifteen files of each brand were used in cyclic fatigue test and other fifteen files for flexural test and torsional failure test. To the cyclic fatigue test, used torque limit and revolutions per minute were set according to the respective manufacturer guidelines. The test was performed under deionized water at 36°C, and all files were tested in a 3 mm radius of curvature with an angle of curvature of 60°, time of the fracture was recorded. Torsional fatigue test was performed in the torsional machine (Instron MT, USA), recording the fractured time and torque data by the machine software. Flexural fatigue test was performed in 60° of curvature. All data were statistically analyzed by one-way analysis of variance, and Tukey test for multiple comparisons. RESULTS: Cyclic fatigue (seconds)= HYF: 744.1 ± 231.9/GEN: 477.3 ± 220.5/WO: 278.4 ± 57.0/PTU: 152.4 ± 65.2; torsional failure (N × cm)= HYF: 6.85 ± 1.484/GEN: 6.55 ± 0.828/WOG: 5.73 ± 0.360/PTU: 4.43 ± 0.900; flexural resistance (N × mm)= HYF: 0.33 ± 0.294/GEN: 0.19 ± 0.136/WOG: 0.98 ± 0.216/PTU: 1.85 ± 0.276. CONCLUSION: HYF and GEN showed the best results for cyclic fatigue, torsional failure, and flexural resistance, followed by WOG and PTU.

4.
ScientificWorldJournal ; 2015: 125636, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26346574

RESUMO

This study was conducted to compare the effectiveness of different irrigants used to remove endotoxins and cultivable microorganisms during endodontic therapy. Forty root canals were contaminated and divided into groups according to the irrigant: 2% NaOCl + surfactant, 2% CHX, 2.5% NaOCl, and pyrogen-free saline solution (control). Samples were collected after root canal contamination (S1), after instrumentation (S2), and 7 days after instrumentation (S3). Microorganisms and endotoxins were recovered from 100% of the contaminated root canals (S1). At S2, 2% NaOCl + surfactant, 2% CHX, and 2.5% NaOCl were able to completely eliminate cultivable microorganisms. At S3, both 2% CHX and 2.5% NaOCl were effective in preventing C. albicans and E. coli regrowth, but E. faecalis was still detected. No microorganism species was recovered from root canals instrumented with 2% NaOCl + surfactant. At S2, a higher percentage value of endotoxin reduction was found for 2% NaOCl + surfactant (99.3%) compared to 2% CHX (98.9%) and 2.5% NaOCl (97.18%) (p < 0.05). Moreover, at S3, 2% NaOCl + surfactant (100%) was the most effective irrigant against endotoxins. All irrigants tested were effective in reducing microorganisms and endotoxins from root canals. Moreover, 2% NaOCl + surfactant was the most effective irrigant against endotoxins and regrowth of microorganisms.


Assuntos
Cavidade Pulpar/microbiologia , Endotoxinas , Pulpite/tratamento farmacológico , Pulpite/microbiologia , Irrigantes do Canal Radicular/administração & dosagem , Carga Bacteriana , Candida albicans/efeitos dos fármacos , Enterococcus faecalis/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Humanos , Testes de Sensibilidade Microbiana
5.
Braz Oral Res ; 292015.
Artigo em Inglês | MEDLINE | ID: mdl-26017490

RESUMO

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm(2) of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey's tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm(2) (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm(2) at all curing distances.


Assuntos
Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários/instrumentação , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Resinas Compostas/química , Equipamentos Odontológicos , Teste de Materiais , Polimerização/efeitos da radiação , Doses de Radiação , Equipamentos e Provisões para Radiação , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo
6.
Gen Dent ; 63(2): 71-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25734291

RESUMO

In this study, scanning electron microscopy (SEM) was used to evaluate the smear layer removal of 3 irrigation devices. The study hypothesis was that more contemporary side-vented needles and brush-covered needles are more efficient for smear layer removal of root canals than traditional needles. The aim of this study was to compare the effectiveness of these irrigation devices in the cleansing of root canals instrumented with oscillatory and rotary systems. Sixty single-rooted teeth were divided according to instrumentation and irrigation techniques into 6 groups. The teeth were prepared for SEM analysis to evaluate the cleansing of cervical, middle, and apical thirds. For all groups, the cleansing of the cervical and middle thirds was better than that of the apical third (P < 0.05). Regardless of the instrumentation technique, no statistically significant differences were found between the groups regarding the cleansing of root canal walls (P > 0.05).


Assuntos
Preparo de Canal Radicular/métodos , Irrigação Terapêutica/métodos , Instrumentos Odontológicos , Humanos , Microscopia Eletrônica de Varredura , Agulhas , Irrigação Terapêutica/instrumentação , Resultado do Tratamento
7.
J Biomed Opt ; 20(3): 038002, 2015 03.
Artigo em Inglês | MEDLINE | ID: mdl-25782626

RESUMO

This research analyzed the quality of resin-based sealer adaptation after intracanal laser irradiation. Extracted teeth (n = 168) were root canal treated and divided into four groups, according to dentin surface treatment: no laser; Nd:YAG laser (1.5 W, 100 mJ, 15 Hz); diode laser (2.5 W in CW), and Er:YAG laser (1 W, 100 mJ, 10 Hz). The teeth were divided into four subgroups according to the sealer used: AH Plus, EndoREZ, Epiphany, and EpiphanySE. For testing the sealing after root canal obturation, the penetration of silver nitrate solution was measured, whereas to evaluate the adaptation and penetration of the sealer into the dentin, environmental scanning electron microscopy (ESEM) was used. The ESEM images were analyzed using a four-grade criteria score by three evaluators. The inter-examiner agreement was confirmed by Kappa test and the scores statistically compared by the Kruskal-Wallis' test (p < 0.05). Both adaptation and sealer penetration in root canals were not affected by the laser irradiation. Nd:YAG and diode laser decreased the tracer penetration for AH Plus, whereas EndoREZ and EpiphanySE performances were affected by Nd:YAG irradiation (p < 0.05). It can be concluded that intracanal laser irradiation can be used as an adjunct in endodontic treatment; however, the use of hydrophilic resin sealers should be avoided when root canals were irradiated with Nd:YAG laser.


Assuntos
Cavidade Pulpar/efeitos da radiação , Dentina , Lasers de Estado Sólido/uso terapêutico , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos , Nitrato de Prata/uso terapêutico , Cavidade Pulpar/diagnóstico por imagem , Dentina/diagnóstico por imagem , Resinas Epóxi , Humanos , Terapia a Laser/métodos , Microscopia Eletrônica de Varredura , Estatísticas não Paramétricas
8.
Braz Oral Res ; 29: 1-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25466329

RESUMO

Root canal preparation is an important step in endodontic treatment. The anatomical complexity of the middle third of the root compromises the effective cleaning of this area. Thus, advances have been made in instrumentation techniques and instruments for this purpose. The aim of this study was to evaluate the effects of three different instrumentation systems on the enlargement of the middle thirds of root canals in mandibular incisors. The preparation methods used were the reciprocating systems Reciproc (Group I) and WaveOne (Group II) and the oscillatory system Tilos (Group III). Comparisons were made by three-dimensional image reconstruction with cone-beam computed tomography before and after instrumentation. Changes in area, perimeter, centering ability, and pattern of preparation were analyzed. The results were subjected to ANOVA complemented by the Tukey's test. Changes in area, perimeter, and tendency of transportation showed similar results among groups. The transportation index of the Tilos system was significantly lower than that of the other groups. Qualitative analysis of the preparation pattern showed that the Tilos system had a more uniform preparation, although Reciproc and WaveOne preparations appeared more rounded, incompatible with the original canal anatomy. There was similarity in the systems' performance on flattened areas, although the Tilos system presented a better pattern of root canal preparation and a lower index of transportation.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Análise de Variância , Instrumentos Odontológicos , Humanos , Imageamento Tridimensional , Teste de Materiais , Níquel , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Estatísticas não Paramétricas , Fatores de Tempo , Titânio
9.
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777229

RESUMO

Root canal preparation is an important step in endodontic treatment. The anatomical complexity of the middle third of the root compromises the effective cleaning of this area. Thus, advances have been made in instrumentation techniques and instruments for this purpose. The aim of this study was to evaluate the effects of three different instrumentation systems on the enlargement of the middle thirds of root canals in mandibular incisors. The preparation methods used were the reciprocating systems Reciproc (Group I) and WaveOne (Group II) and the oscillatory system Tilos (Group III). Comparisons were made by three-dimensional image reconstruction with cone-beam computed tomography before and after instrumentation. Changes in area, perimeter, centering ability, and pattern of preparation were analyzed. The results were subjected to ANOVA complemented by the Tukey’s test. Changes in area, perimeter, and tendency of transportation showed similar results among groups. The transportation index of the Tilos system was significantly lower than that of the other groups. Qualitative analysis of the preparation pattern showed that the Tilos system had a more uniform preparation, although Reciproc and WaveOne preparations appeared more rounded, incompatible with the original canal anatomy. There was similarity in the systems’ performance on flattened areas, although the Tilos system presented a better pattern of root canal preparation and a lower index of transportation.


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Análise de Variância , Instrumentos Odontológicos , Imageamento Tridimensional , Teste de Materiais , Níquel , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Estatísticas não Paramétricas , Fatores de Tempo , Titânio
10.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777230

RESUMO

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.


Assuntos
Lâmpadas de Polimerização Dentária , Resinas Compostas/efeitos da radiação , Cura Luminosa de Adesivos Dentários/instrumentação , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Resinas Compostas/química , Equipamentos Odontológicos , Teste de Materiais , Polimerização/efeitos da radiação , Doses de Radiação , Equipamentos e Provisões para Radiação , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo
11.
Braz. oral res ; 27(1): 26-30, Jan.-Feb. 2013. tab
Artigo em Inglês | LILACS | ID: lil-660455

RESUMO

The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by high-resolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.


Assuntos
Humanos , Instrumentos Odontológicos , Cavidade Pulpar , Preparo de Canal Radicular/instrumentação , Microtomografia por Raio-X , Ligas Dentárias , Dentina/química , Desenho de Equipamento , Níquel , Distribuição Aleatória , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Aço Inoxidável , Estatísticas não Paramétricas , Propriedades de Superfície , Titânio
12.
Braz Oral Res ; 27(1): 26-30, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23207901

RESUMO

The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by high-resolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.


Assuntos
Instrumentos Odontológicos , Cavidade Pulpar/diagnóstico por imagem , Preparo de Canal Radicular/instrumentação , Microtomografia por Raio-X , Ligas Dentárias , Dentina/química , Desenho de Equipamento , Humanos , Níquel , Distribuição Aleatória , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Aço Inoxidável , Estatísticas não Paramétricas , Propriedades de Superfície , Titânio
13.
Braz. oral res ; 26(4): 323-329, July-Aug. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-640717

RESUMO

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the RealSeal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the RealSeal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).


Assuntos
Humanos , Infiltração Dentária , Lasers Semicondutores , Materiais Restauradores do Canal Radicular/efeitos da radiação , Dentina/química , Dentina/efeitos da radiação , Resinas Epóxi/química , Resinas Epóxi/efeitos da radiação , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Estatísticas não Paramétricas , Propriedades de Superfície
14.
Braz Oral Res ; 26(4): 323-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22714928

RESUMO

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the RealSeal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the RealSeal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).


Assuntos
Infiltração Dentária , Lasers Semicondutores , Materiais Restauradores do Canal Radicular/efeitos da radiação , Dentina/química , Dentina/efeitos da radiação , Resinas Epóxi/química , Resinas Epóxi/efeitos da radiação , Humanos , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Estatísticas não Paramétricas , Propriedades de Superfície
15.
Braz Dent J ; 22(5): 377-81, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22011892

RESUMO

The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5% methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Student's t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.


Assuntos
Infiltração Dentária/classificação , Cavidade Pulpar/efeitos da radiação , Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Materiais Restauradores do Canal Radicular/uso terapêutico , Ápice Dentário/efeitos da radiação , Corantes , Colagem Dentária , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Resinas Epóxi/química , Resinas Epóxi/uso terapêutico , Guta-Percha/química , Guta-Percha/uso terapêutico , Humanos , Teste de Materiais , Azul de Metileno , Microscopia Eletrônica de Varredura , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/métodos , Camada de Esfregaço , Fatores de Tempo , Ápice Dentário/ultraestrutura
16.
Am J Orthod Dentofacial Orthop ; 140(1): e43-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21724070

RESUMO

INTRODUCTION: Our objective was to assess the effectiveness of a new bleaching agent (8% hydrogen peroxide) used in patients wearing fixed orthodontic appliances. METHODS: Six anterior maxillary teeth of 40 patients aged 18 to 40 years were assessed. The patients were divided into 2 groups (20 in each group): in group A, the patients used the bleaching agent during orthodontic treatment; in group B, the patients used the bleaching agent after orthodontic treatment. For each group, a record of the initial tooth shade was taken with a polyvinyl siloxane matrix and a spectrophotometer. The groups had bleaching treatments with an 8% hydrogen peroxide product (Opalescence Treswhite Ortho, Ultradent, Opal Orthodontics, South Jordan, Utah) for 10 days in 45-minute sessions. For group A, the treatment was performed 10 days before finishing orthodontic treatment; at the end of the treatment, a new tooth shade record was taken with the polyvinyl siloxane matrix and a spectrophotometer. The subjects in group B had the same bleaching protocol after their brackets were removed. RESULTS: It was observed that, for the group without brackets, the color alteration ranged from 3 to 12 (mean, 8; median, 8.3); for the group with brackets, the range was between 4 and 13 (mean, 9; median, 8.5), indicating significant tooth bleaching in both groups with and without brackets (P >0.05). CONCLUSIONS: Opalescence Treswhite Ortho was shown to be an efficient bleaching agent in patients wearing fixed orthodontic appliances.


Assuntos
Peróxido de Hidrogênio/farmacologia , Braquetes Ortodônticos , Clareadores Dentários/farmacologia , Clareamento Dental/métodos , Adolescente , Adulto , Dente Canino , Feminino , Humanos , Peróxido de Hidrogênio/administração & dosagem , Incisivo , Masculino , Espectrofotometria , Estatísticas não Paramétricas , Fatores de Tempo , Clareadores Dentários/administração & dosagem , Adulto Jovem
18.
Braz. dent. j ; 22(5): 377-381, 2011. ilus
Artigo em Inglês | LILACS | ID: lil-601837

RESUMO

The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5 percent methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Student’s t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.


Assuntos
Humanos , Infiltração Dentária/classificação , Cavidade Pulpar/efeitos da radiação , Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Materiais Restauradores do Canal Radicular/uso terapêutico , Ápice Dentário/efeitos da radiação , Corantes , Colagem Dentária , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Resinas Epóxi/química , Resinas Epóxi/uso terapêutico , Guta-Percha/química , Guta-Percha/uso terapêutico , Teste de Materiais , Microscopia Eletrônica de Varredura , Azul de Metileno , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/métodos , Camada de Esfregaço , Fatores de Tempo , Ápice Dentário/ultraestrutura
19.
Am J Dent ; 23(3): 171-4, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20718216

RESUMO

PURPOSE: To quantify the amount of peroxide penetration from the pulp chamber to the external surface of teeth during the walking bleaching technique. METHODS: Seventy-two bovine lateral incisors were randomly divided over five experimental groups and one control (n = 12 per group): (1) 35% hydrogen peroxide (HP); (2) 35% carbamide peroxide (CP); (3) sodium perborate (SP); (4) (HP+SP); (5) (CP+SP) and (6) Control (CG), deionized water. All groups were treated according to the walking bleach technique. After 7 days at 37 degrees C in an acetate buffer solution, 100 microl violet leukocrystal coloring and 50 microl peroxidase was added, producing a blue stain that could be measured in a spectrophotometer and then converted into peroxide microg/ml. RESULTS: G5 exhibited the greatest penetration, while G2 and G3 produced the lowest values. All bleaching agents penetrated from the pulp chamber to the external root surface. There was a direct correlation between the presence of oxidative agents and penetration potential. Sodium perborate in distilled water was less oxidative and appeared to be the least aggressive bleaching agent.


Assuntos
Boratos/farmacocinética , Peróxido de Hidrogênio/farmacocinética , Oxidantes/farmacologia , Peróxidos/farmacocinética , Clareamento Dental/métodos , Colo do Dente/metabolismo , Ureia/análogos & derivados , Condicionamento Ácido do Dente , Animais , Boratos/administração & dosagem , Peróxido de Carbamida , Bovinos , Cemento Dentário/metabolismo , Permeabilidade do Esmalte Dentário , Permeabilidade da Dentina , Relação Dose-Resposta a Droga , Combinação de Medicamentos , Peróxido de Hidrogênio/administração & dosagem , Oxirredução , Peróxidos/administração & dosagem , Distribuição Aleatória , Dente não Vital , Ureia/administração & dosagem , Ureia/farmacocinética
20.
RSBO (Impr.) ; 6(2): 163-168, jun. 2009. ilus, tab
Artigo em Português | LILACS-Express | LILACS | ID: lil-514884

RESUMO

Introdução e objetivo: Buscou-se avaliar in vitro o grau de aquecimento promovido no interior da câmara pulpar após o uso de diferentes agentes clareadores, com ou sem ativação por fontes de luz. Material e métodos: Foram utilizados 60 dentes incisivos bovinos, que receberam acesso ao canal radicular pela face lingual, com a parede vestibular padronizada em 2 mm. Os espécimes foram divididos em 6 grupos (n = 10), de acordo com o agente clareador e a fonte de ativação utilizada: G1 - ausência de agente clareador e aplicação de luz halógena; G2 - ausência de agente clareador e aplicação de LED; G3 - aplicação do agente clareador Whiteness HP Maxx (peróxido de hidrogênio 35%) e ativação com luz halógena; G4 - aplicação do agente clareador Whiteness HP Maxx (peróxido de hidrogênio 35%) e ativação com LED; G5 - aplicação do agente clareador Opalescence Xtra Boost (peróxido de hidrogênio 38%) e ativação com fotopolimerizador; G6 - aplicação do agente clareador Opalescence Xtra Boost (peróxido de hidrogênio 38%) e ativação com LED. A variação da temperatura na câmara pulpar foi mensurada com um aparelho termopar. Resultados: Os valores de temperatura foram medidos pelo aparelho durante 10 minutos, com alguns intervalos selecionados: t1 - temperatura inicial; t2 - após 25 segundos de aplicação do gel e 20 segundos de ativação; t3 - após 10 minutos. Os valores obtidos foram registrados pela máquina no software, e os dados foram submetidos à análise estatística pelo teste Anova. Verificou-se que o aumento da temperatura não foi significante em todos os grupos testados. Conclusão: Não foram encontradas diferenças estatisticamente significantes entre os grupos com e sem ativação por fontes de luz ou entre os diferentes clareadores.


Introduction and objective: To evaluate in vitro the degree of warming promoted within the pulp chamber, after the use of bleaching agents, with or without activation by light sources. Material and methods: Sixty bovine teeth were used, which had received access to the root canal by the side lingual, with the wall vestibular standardized at 2 mm. The specimens were divided into 6 groups (n = 10), according to the bleaching agent and the source of activation used: G1 - absence of bleaching agent and application of halogen light; G2 - absence of bleaching agent and application of LED; G3 - application of the Whiteness HP Maxx (35% hydrogen peroxide) and activation with halogen light; G4 - application of Whiteness HP Maxx (35% hydrogen peroxide) and activation with LED; G5 - application of the Opalescence Xtra Boost (38% hydrogen peroxide) and activation with photopolymerizer; G6 - application of the Opalescence Xtra Boost (38% hydrogen peroxide) and activation with LED. The change of temperature in the pulp chamber was measured using a Termopar apparatus. Results: The values of temperature were measured by the device during an interval of 10 minutes, with some selected intervals: t1 - initial temperature; t2 - after 25 seconds of application of the gel and 20 seconds of activation; t3 - after 10 minutes. The values were registered by the machine in the software and the data were subjected to statistical analysis using the Anova test. Conclusion: There were no statistically significant differences between groups with and without activation or between different bleaching.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...